ADCP-92-098 • Rev C • May 2018
Page 13
© 2018
CommScope
. All Rights Reserved.
2.7
Installing MPO Cassettes
The 1U panel accommodates two MPO cassettes, the 2U accommodates four. The procedure for
the 1U and 2U is the same. To install or remove an MPO cassette, pull the Nylatch plunger
fastener out, orienting the MPO as shown in
Figure 13
.
Figure 13. Installing MPO Cassettes
Caution:
Adapter packs and MPO cassettes should not be both used in the same panel.
INSTALL LEFT SIDE MPO
CASSETTES WITH ADAPTERS
ANGLED TOWARD THE LEFT
INSTALL RIGHT SIDE MPO
CASSETTES WITH ADAPTERS
ANGLED TOWARD THE RIGHT
INSTALL MPO CASSETTES
IN ORIENTATION SHOWN
NYLATCH PLUNGER FASTENERS MUST BE
PULLED OUT BEFORE INSERTING THE
MPO CASSETTE INTO MOUNTING HOLES
IN PANEL
AFTER INSTALLING MPO CASSETTE,
PUSH NYLATCH PLUNGER FASTENERS
"IN" TO LOCK CASSETTE INTO PANEL
"OUT"
POSITION
"IN"
POSITION
23948-B