![CommScope FOSC-450A Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/commscope/fosc-450a/fosc-450a_installation-instruction_2643707006.webp)
6
4.3.10 Insert the drop cable assembly through the FOSC 450 closure
base and position it into the designated port.
4.3.11 Position the teeth of the cable retention brackets onto the felt
wrap and secure with the hose clamp.
Note
: the head of the hose clamp has to be positioned on top of the
cable retention bracket. Otherwise it might interfere with the base when
assembled.
4.4
Tube routing
Note
: begin splicing on the bottom tray (closest to the metal slack
basket), other empty trays can be removed until needed.
Loose Buffer Tube (loop or single drop)
4.4.2 Slide the appropriate transportation tube over the loose tube
and route to the tray. Mark at 15 mm from the tray edge. Remove the
tube excess from the mark and secure to the tray with tie-wraps.
4.4.1 In case of a loop, select the appropriate loose tube and cut in
the middle. Strip the loose tube at 40 mm from the jacket.
4.4.3 The uncut loops can be stored in the basket if available or in a
plastic bag. Secure the loops with tie-wraps.
Note
: in case of modular cables(multi-out): Store the uncut loops on top
of the loose tubes that are passing thru the basket. See section 8 for
loop capacity in the basket.