12
6.5
If a tray for up to 16 ant splice protectors is used (FOSC-A-
TRAY-A16)
• the tray organizer has 6 locations to store splice protectors. Each
location can hold maximum 4 fusion splice protectors of type smouv-
1120-02 (length 45 mm, installed outer diameter is 2,4 mm) or
equivalent.
• After each splice is made, the splice should be stored as indicated
on the drawing. First protector in position 1, the second in position
2. Continue for other fibers. Fiber nr. 5 will be in position 1 of next
location.
• If splice protectors are stored on the side with the 4 locations, the
fibers from the locations on the outside are first guided through the
passage between the locations and then coiled into the tray.
• he tray organizer has 4 locations to store protectors. Each location
can hold maximum 4 fusion splice protectors of type ANT.
• Coil the excess length of fiber each time you have positioned the
splice protector.
• the tray organizer has 6 locations to store splice protectors. Each
location can hold maximum 4 fusion splice protectors of type ANT.
• After each splice is made, the splice should be stored in the splice
holder.
• If splice protectors are positioned on the side with the 4 locations,
the fibers from the locations on the outside are first routed through
the passage between the locations and then coiled into the tray.
6.4
If a tray for up to 24 heat-shrinkable fusion splice protectors
is used ( FOSC-A-TRAY-S24)
6.6
If a tray for up to 24 ant splice protectors is used ( FOSC-A-
TRAY-A24)
• the tray organizer has 6 locations to store splice protectors. Each
location can hold maximum 4 fusion splice protectors of type smouv-
1120-02 (length 45 mm, installed outer diameter is 2,4 mm) or
equivalent.
• After each splice is made, the splice should be stored as indicated
on the drawing. First protector in position 1, the second in position
2. Continue for other fibers. Fiber nr 5 will be in position 1 of next
location.
• If splice protectors are stored on the side with the 4 locations, the
fibers from the locations on the outside are first guided through the
passage between the locations and then coiled into the tray.
Содержание FOSC-450A