Installing CAP Ms
Determine the Power Consumption of the CAP M
Use the power consumption matrix in
to calculate power consumption for a CAP M, where
•
the consumption numbers are at the CAP M power inputs and do not account for feed losses
•
the maximum consumption numbers in
do not include the power consumed by any attached
auxiliary devices. Both CAP M power consumption and auxiliary device power must be included when
calculating feed losses.
Determine the Mounting Site
When deciding on a suitable mounting site, observe the following rules; refer also to
.
•
The CAP M is suitable for installation indoors or outdoors.
•
Use the weights listed in
to determine a site that can bear the weight of the CAP M that is being
installed, where:
–
The “Maximum Lift Weight” is the highest weight that must be lifted during installation. (An installer
should lift the CAP M components one at a time, not a wholly configured CAP M.)
–
The “Total Hanging Weight” is the weight of the CAP M, including the weight of the Mounting Bracket,
minus the weight of the external cables and connectors, that the mounting site must be able to
support.
•
for Dual
Mount.
Table 5.
CAP M Power Consumption
Configuration
Voltage Range (V)
Typical Power (W)
Maximum Power (W)
DC
1
36 - 60 Vdc
140
150
AC
1
100 - 264 Vac
140
150
1
Does not include SFP+ Module consumption. Can support up to 3W (more with engineering
consultation) maximum total SFP+ Module consumption. Typical installation (sufficient for SM up to
10km or MM) would be 0.8W typical, 1.0W max for each SFP+ Module.
Mains power must be interruptible with an external delay-actions mains breaker. For the Mains breaker,
observe the following recommendations.
•
For the AC power supply, 120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC
service is needed, i.e. the external AC breaker should be 20 Amps max. for 120-Volt service or 13 to
16 Amps for 240-Volt service.
•
For the DC power supply, observe the local regulations of the DC service provider.
Table 6.
Maximum CAP M Installation Weights
1
CAP M installed with this option …
Maximum Lift
Weight
Total Hanging
Weight
kg
lbs. kg
lbs.
Single Mounting Bracket (PN 7821954-xx)
19.2
42.3 20.5
45.2
Dual Mounting Bracket (PN 7821955-xx)
19.2
42.3 40
88.2
1
A Hybrid Fiber Splice Box (PN 7693816-xx) adds 0.3 kg (.66 lbs.) to the total
weights.