Instruction Sheet
Page 3 of 7
Preparation
1. Determine location for all fixtures and
Redwood
dimmers.
2. Determine location for all
Redwood
engines. The engine is a 1.5U rack mountable system and can be
installed in a standard server rack using supplied rack-mounting L brackets, or to the wall with a
Redwood
wall mount kit.
3. Run low-voltage cable from engine location to each fixture location.
4. Run low-voltage cable from the engine location to each
Redwood
dimmer location.
5. Options for connector preparation:
If using the RJ45 connector, it can be wired as T568A (straight through) or T568B (crossover).
If using 18 AWG (1mm) wiring to connect to the engine, use a
Redwood
RJ45 terminator on the 18
AWG wire.
6. Install third-
party light fixtures according to vendor’s installation instructions.
Installation
Rack Mount Instructions
1. Attach the two rack mount brackets to
each side of the engine using 3
screws provided on each side as
shown.
2. With power disconnected, install
engine in a standard server rack,
using mounting brackets (included).
Ensure that air vents are not blocked
and that the conditions support the
ambient operation temperature of
32°F to 122°F (0°C to 50°C).
3. Connect the cables.