MT Series DryLine
®
Dehydrator User Manual
6
Install Polyethylene Tubing Lines
• Output lines (4) with individual valves.
• Pressure sense line (Remote Sense)
• Connect the Transmission Line Tubing.
Insert the tubing runs from the transmission
lines into the fittings in the top panel marked
“Outlet”.
Connect the Remote Sense Line Tubing. Insert
a single tubing run from the transmission line
into the fitting in the top panel marked “Remote
Sense”.
Install the isolation shutoff valves. The valves
when used on output lines, allow the system
to retain pressure while the system is removed
for servicing. Place each valve in line between
each output and transmission line.
Do not
install the “Remote Sense” and “Output”
lines into a Tee Fitting into one port on the
transmission line. The dehydrator will not
operate properly.
CAUTION:
Do not operate the unit with the
Remote Sense line disconnected,
this may result in an over pressure
condition. Also be sure that any
isolation valves are open before
operating the unit.