![CommScope COWO Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/commscope/cowo/cowo_installation-instructions-manual_2643562009.webp)
9
7 Fiber management inside splice cassette
8 Adapter positions
8.1
Two positions of adapter are possible. In the front position the
plug can be accessed with the box closed. At the inside position the
plug cannot be accessed when the box is closed and/or sealed. The
box needs to be opened first. When the box is sealed, this set-up can
prevent unauthorized access to the plug.
7.1
The spare length of the fibers coming from the left side of the
base (1.2 m) is guided to the right side of the cassette and wound up
in here in a clockwise direction. The ends of the fibers are guided to the
splice holders on the left side of the cassette for splicing. The outgoing
fibers with a maximum spare length of 1.2 m are looped clockwise
as well and are leaving the cassette to the right. With this set-up the
cassette can be rotated upwards again and the fiber management can
be continued in the base of the box.
NOTE:
When installing a new adapter, make sure that the
attached spring is removed.