1   General

Customer Wall Outlet 2 Fiber for max. 2 bend reduced fibers, 2 
SC-adapters or 1 LC-Duplex adapter. 
The box is designed for indoor applications for a maximum of 2 fibers. 
The maximum fiber length is 1.2 m before and 1.2 m after the splice. 
Up to 2 SC- or 1 LC-Duplex-Adapter can be inserted. The box is wall 
mountable or can be mounted onto a wall box with a mounting hole 
distance of 60 mm. 
The box provides cable entrances (Ø 3 - 7 mm) on the left hand, top, 
bottom and back side of the box. The box can also be loaded with 
max. 2 pre-assembled cables (drop cable) Ø 3 mm from the bottom or 
back side. A hinged splice cassette inside, can support max. 2 crimp 
splices, 2 heat shrinkable splices. The box can be protected with a 
screw or wire seal. 

COWO

I N S T A L L A T I O N   I N S T R U C T I O N

Customer Wall Outlet

2    Kit content

3    Handling of the box

•  2 X Screw ISO 7049 ST3,5x30-C-H-A2 
•  2 x Wall Plug D5-25 
•  1x Installation Instruction
•  1x Screw M5 (for securing the box)

3.1  

To open the cover press the engagement hook in the middle 

of the bottom side of the base (as shown) and pull the cover upwards. 
A screw driver can be used to assist in opening the cover. At about 
120° the cover will lock in place. It is possible to remove the cover 
completely , by pushing, if needed. To close the cover, push the cover 
down until in the hook is engaged. 

3.2  

To open the cassette press the engagement hook in the 

middle of the bottom side of the base (as shown) and pull the cassette 
upwards. At about 105° the cassette will lock in place. To close the 
cassette, push the cassette down until it snaps in. 

TC-1203-IP
Rev A, Apr 2017
www.commscope.com

Содержание COWO

Страница 1: ...d with a screw or wire seal COWO I N S T A L L A T I O N I N S T R U C T I O N Customer Wall Outlet 2 Kit content 3 Handling of the box 2 X Screw ISO 7049 ST3 5x30 C H A2 2 x Wall Plug D5 25 1x Instal...

Страница 2: ...its receptacle in the cassette see above Cable guide for second cable Position the cable guide according to the intended cable entry and push the cable guide into place by aligning the 2 domes with th...

Страница 3: ...able 3 4 3 Open up the cable entry if 2 cables will be cable 3 7 mm 3 4 4 Open up the cable entries in vase and cable guide if cable diameters 5mm 3 4 5 Remove the small rib in the base if required in...

Страница 4: ...cal Tighten the screws 3 6 Remove all burrs and sharp edges from the cable entries and adapter port with a sharp knife e g carpet cutter 4 3 Vertical wall mounting holes 1 Horizontal wall mounting hol...

Страница 5: ...wn aligning the end of the cable sheath with the cable stop at the bottom of the box The fibers coming from the bottom entry of the box are routed to the splice cassette through a channel as shown Gui...

Страница 6: ...splicing is done Secure the cable using the strain relief 5 4 Observe the minimum bend radius for the cable when it is outside the wall box Excess length should wound up behind the box in a loop For...

Страница 7: ...Aramid Fibers to length as shown above Put the Aramid Fibers through the slot of the strain relief as shown and push the fibers on both sides of the strain relief down Ensure that all fibers are under...

Страница 8: ...le entry 125mm 6 2 In case of strain relief second cable repeat the steps from point 6 1 6 4 In case of strain relief top cable entry repeat the steps from point 7 1 v 5 3 In case of strain relief bac...

Страница 9: ...ength of the fibers coming from the left side of the base 1 2 m is guided to the right side of the cassette and wound up in here in a clockwise direction The ends of the fibers are guided to the splic...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...specifications or warranties relating to CommScope products or services This product is covered by one or more U S patents or their foreign equivalents For patents see www commscope com ProductPatent...

Отзывы: