            Re-attach Swing Frame Stops 

 

 

 

         Re-install Ground Wires

 

          Re-attach Ground Wire at Cable 

 

 

             Re-attach Ground Wire at Locate Panel

6.6 

Transfer label information to new doors.

 

 

       Apply New Labels

6.7 

Close and lock the cabinet doors.

 

           Close and Lock Cabinet Doors

Содержание 864 FDH RESKIN KIT

Страница 1: ...imum bend radius Always observe the recommended bend radius limit when installing fiber optic cables and patch cords 2 2 Exposure to laser radiation can seriously damage the retina of the eye Do not look into the ends of any optical fiber Do not assume the laser power is turned off or that the fiber is disconnected at the other end 3 Kit Content Cabinet shell including center post and locate panel...

Страница 2: ...e in good condition Check Condition of Swing Frames and Center Post Tool List Note If the riser is damaged a new riser kit will need to be ordered separately Tools required for installation 5 32 Hex Head Bit 9 16 Socket Wrench 3 8 Socket Wrench Can Wrench Large Phillips Screwdriver 5 3 Remove front hex head screws Note Retain all mounting hardware and ground wires for later re use Hardware Removal...

Страница 3: ...t plates 6 Pictures Hardware Removal on Rear Side LHS Rear Plate Removal LHS Rear Plate Removal LHS Rear Plate Removal RHS Rear Plate Removal RHS Rear Plate Removal 5 5 Remove ground straps from cables and ground locate panel 2 Pictures Cable Ground Strap Locate Panel Ground Strap ...

Страница 4: ...e Stops Lower Swing Frame Door Stop 5 7 Remove bolts from base of cabinet shell There are 4 bolts under the RHS swing frame and 4 bolts under the LHS swing frame Cabinet Shell Bolt Removal 5 8 Remove the screws holding the central post to the FDH shell 2 Pictures Top Center Post Hardware Removal Bottom Center Post Hardware Removal ...

Страница 5: ... in the open position Tape on Swing Frame Latch 5 10 Remove the damaged cabinet shell by moving it toward the front and away from the swing frames 2 Pictures Cabinet Shell Removal Cabinet Shell Moved Away from Swing Frames and Center Post 5 11 Support the swing frames using wood blocks Swing Frame Support ...

Страница 6: ...cable install the new riser Riser Kick Plate Removal 6 2 Remove swing frame stops from new cabinet shell at both the top and bottom 2 Pictures Top Swing Frame Stop Removal Bottom Swing Frame Stop Removal 6 3 Remove the center post from the new cabinet shell 2 Pictures Bottom of Center Post Center Post Removal ...

Страница 7: ...l in Position for Placement New Cabinet Shell Placed Over Swing Frames and Center Post 6 5 Attach center post to new cabinet shell and then reassemble cabinet in reverse order 10 Pictures Center Post Re attachment Re attach Cabinet Shell Bolts Re attach Front Screws Re attach RHS Bottom Plate Re attach LHS Plate Remove Tape from Swing Frame Latches ...

Страница 8: ...ed Re attach Swing Frame Stops Re install Ground Wires Re attach Ground Wire at Cable Re attach Ground Wire at Locate Panel 6 6 Transfer label information to new doors Apply New Labels 6 7 Close and lock the cabinet doors Close and Lock Cabinet Doors ...

Страница 9: ...y with a number of CommScope s facilities across the globe certified in accordance with international standards including ISO 9001 TL 9000 and ISO 14001 Further information regarding CommScope s commitment can be found at www commscope com About Us Corporate Responsibility and Sustainability This product may be covered by one or more U S patents or their foreign equivalents For patents see www cs ...