background image

FEATURES

ViaAqua® Poly

 

Reactor

TM

 is built with high quality acrylic and an easy to remove lid 

with a recessed o-ring. The reverse water flow design eliminates water channeling 

through the filter media thus efficiently utilizing filtering media. ViaAqua® Poly

 

Reactor

TM

 comes complete and ready to run with a pump and all plumbing parts. 

ViaAqua® Poly

 

Reactor

TM

 is designed to be installed either in-sump or hang on the 

tank. 

WARNING AND SAFEGUARD 

WARNING

 

»

This product may contain chemicals known to the State of California to 

cause cancer and/or birth defects or other reproductive harm. Wash you 

hand after handling the product.

 

»

It is your sole responsability to verify that the plug and receptacle are 

clean/free of moisture and salt build up at all times. The receptacle must 

be free of water, salt, calcium, and magnesium. Failure to do so may cause 

fire and/or loss of life. 

 

»

Do not plug into an extension cord or power strip. 

 

»

A drip loop must be used when plug into any electrical devices. A drip 

loop is part of the cord hanging below the receptacle.

 

»

The national code requires all aquarium equipment to be plugged into 

a G.F.C.I. (Ground Fault Circuit Interrupter) electrical outlet. If you do 

not have a G.F.C.I., have an electrician install one prior to operating any 

aquarium components.

•  Read and follow all instructions before using the ViaAqua® Poly

 

Reactor

TM

 to 

ensure proper use and application.

•  Use this product for its intended use only.

• 

Do not operate ViaAqua® Poly

 

Reactor

TM

 without 

water. Doing so can cause permanent damage to the 

pump.

•  You must verify that the receptacle is clean and 

free of water, moisture, and salt build up at all 

times. Failure to do so may cause electrical arching 

resulting in fire or electrical shock.

• 

Prior to maintenance on any electrical aquarium 

appliance or aquarium, you must disconnect all 

Drip loop 

1

Содержание Poly-Reactor ViaAqua PR 20/20

Страница 1: ...fety and proper use not in accordance with the directions and sately labels Equipped ready to use Variable flow water pump Intake and output tubing Easy twist off top with recessed o ring Use in sump...

Страница 2: ...ium Failure to do so may cause fire and or loss of life Do not plug into an extension cord or power strip A drip loop must be used when plug into any electrical devices A drip loop is part of the cord...

Страница 3: ...used PART LIST 1 Reaction chamber 2 Down tube 3 Intake tube 4 Sediment discharge filter 5 Barbed fitting 6 Lock nut 7 Lid 8 O ring 9 Media sponge 10 Media strainer 11 Hanger 12 Suction cup bracket 13...

Страница 4: ...the sediment discharge filter to the end of the output tubing 6 Remove the lid by twisting counter clockwise 7 Add desired media to the reaction chamber phosphate resin activated carbon and other resi...

Страница 5: ...Remove either the prefilter or intake filter strainer Rinse out prefilter sponge of all debris c Remove the impeller cover d Once the impeller cover is removed slide both the impeller and shaft out o...

Страница 6: ...7 Control valve 13 2931 4 Media sponges 2 pk 9 2922 2 1 Reaction chamber 2 Down tube 3 Intake tube 4 Sediment discharge filter 5 Barbed fitting 2 6 Lock nut 2 7 Lid 8 O ring 9 Media sponge 2 10 Media...

Страница 7: ...and your sole and exclusive remedy shall be either repair or replacement of the ViaAqua Poly ReactorTM only if you return the defective unit directly to Commodity Axis Inc with the original receipt in...

Страница 8: ...card and proof of purchase within 15 days of purchase to Commodity Axis Inc 300 South Lewis Rd Unit J Camarillo CA 93012 IMPORTANT Please make a copy of this warranty card and retain it for your reco...