10
Care and Cleaning
□
Shut off the main power supply before cleaning the product. To prolong the original appearance, clean the
light fixture with clear water and a soft, damp cloth only.
□
Do not use abrasive cleaners or cleaners that contain alcohol. Do not apply paints, solvents, or any other
chemicals on this light fixture. They could cause a premature deterioration of the finish and may void the warranty.
□
Do not spray the light fixture with a hose or power washer.
Troubleshooting
Problem
Possible Cause
Solution
The light does not
turn ON.
There is no power to
the fixture.
□
Check if circuit breaker is tripped.
□
Confirm wall switch is ON. Verify wiring to the fixture is correct
(turn power OFF to fixture beforehand).
The fixture senses
daylight.
Cover the photocell sensor. Wait several seconds until the fixture
turns ON.
The light cycles
ON and OFF
continuously.
The photocell light
sensor is sensing
reflected light.
□
Relocate the light fixture to a location where there is no
reflected light.
□
OR place the optional photocell cap cover over the photocell
light sensor and use the wall switch to turn the light ON and
OFF.
The light flickers.
The light fixture is
wired through a
dimmer switch.
Do not use a dimmer switch to control the light fixture. Replace the
dimmer with a standard ON/OFF switch.
The light stays
ON.
The light sensor is in a
shaded area.
□
Shine a flashlight into the light sensor and wait a short time.
If the light turns OFF, the fixture should be moved to a location
with enough light in the daylight hours for the light sensor to
work.
□
OR place the optional photocell cover cap over the photocell
light sensor and use the wall switch to turn the light ON and
OFF.
The light sensor is
faulty.
If the light does not turn OFF when a flashlight is shined on the
light sensor for up to one minute, then the sensor may be faulty.
Please contact customer service.
NOTE:
The photocell (B) may have a short delay in order to reduce its sensitivity to sudden light changes. When testing, shine a light/
cover the photocell for up to a minute to check if the fixture functions properly.