8
Installation (continued)
5
Making the electrical
connections
□
For handsfree operation, to allow both hands
to make electrical connections, use the hinge
on the mounting base (D) to hang the fixture.
□
For the conduit mount installation, remove one
conduit plug (B) from the side of the fixture
where the conduit will enter.
□
If necessary, strip 3/8 in. of insulation from the
junction box or fixture (A) wires.
□
Connect the fixture black wire to the supply
black wire ((+) line), and fixture white wire
to the supply white wire ((-) common) by
inserting the exposed supply wires into the
corresponding Wago connector (E). Ensure
there are no loose wires.
□
Connect the supply ground wire to the green
fixture ground wire by inserting the exposed
supply wires into the corresponding Wago
connector (E). Ensure there are no loose wires.
Junction Box Mount
Surface Conduit Mount
B
D
E
A
D
E
3/8 in.
(+) Line
Black
White Lighting
Fixture
Green
(-) Common
Ground