background image

Telephone Interface

G8-S0/G3-S0-I

28

1.1/1010

PABX Mode

Outgoing Phone Call by Dialling Interface Manually

The Intercom station dials the number of the telephone interface (e.g. with direct dialling).

As soon as the conversation to the telephone interface is set up, the Intercom station receives the
“dial tone“ signal and can dial any telephone number.

In addition to the numeric buttons 0 to 9 the following telephone buttons can be dialled at the Intercom
station: 

It is also possible to define a number, that is automatically pre-dialled before the telephone number is
dialled, e.g. an exchange number for dialling out, or for selecting a certain provider.

After Dialling at Telephone 

Outgoing Phone Call by Direct Outward Dialling

It is possible to define several telephone numbers per telephone interface (via the “PA-function“)
which can be dialled 

directly

 at the Intercom station, without having to pre-dial the number of the

interface.

In CCT 800, the following number of

 entries

 of telephone numbers per interface are possible:

Up to

 PRO 800 1.1: 

41

As of

 PRO 800 1.1: 

339

By means of “wildcards” it is possible to integrate several telephone numbers with only one entry
in CCT 800 (

see below

).

This function is only available for 

max. 4-digit

 telephone numbers (PA-codes 

 max. 4-digit, see

current version of the manual “PRO 800”).

A “dummy“ relay contact is required.

In spite of this configured function, a call however can be built up by dialling the interface manually
(

see above

).

Including a Range of Numbers via Wildcards

To simplify the configuration in CCT 800 (

see page 31

), it is possible to define a range of telephone

numbers as “wildcards”.

The telephone numbers included by those wildcards can then be dialled at the Intercom stations as
explained 

above

.

Note:

In case of 

outgoing phone calls

 (via dialling interface manually or direct outward dialling), 

no pass-

word

 has to be entered on the telephone, even if a password is defined in CCT 800 – this is only valid 

for a 

”Call from telephone to Intercom Server”

.

Telephone

Dial at the Intercom station

*

TT

#

T0

A

T1

B

T2

C

T3

D

T4

For outgoing phone calls in PABX mode built up by 

dialling

 the respective

 interface manually

, in

standard 

no after dialling is possible

 at the telephone (i.e. also no cancelling of the call via “#”).

By means of special configuration in CCT 800, it is possible to activate the after dialling function for
the telephone interface 

see ”After Dialling at Telephone – Outgoing Phone Call” on page 31

.

Содержание C-G3-S0-I

Страница 1: ...G8 S0 G3 S0 I VERSION 1 1 1010...

Страница 2: ...utes 8 times every 15 minutes and then every hour If an equipment that answers automatically is connected there e g a modem with Auto Answer Function a chargeable call is built up every time For one c...

Страница 3: ...terface 8 Start Up S0 Network 10 Calling number system 10 Installation 11 Configuration CCT 800 13 Configuration Examples 14 Network Functions 17 Define the block numbers 17 Configure the Block Number...

Страница 4: ...dialler mode is used for transfer of calls and call requests input messages central control calls into the public telephone net The telephone numbers to be dialled can be configured as desired It is...

Страница 5: ...rictions see The ISDN Basic Rate Interface on page 8 Network function The first conversation between two Intercom Servers builds up both B channels one for data and one for speech which are two charge...

Страница 6: ...card software the following restrictions apply Min PRO 800 1 2 Min CCT 800 1 2 The software can be downloaded to a maximum of 4 S0 cards simultaneously During the download max 9 cards of any kind may...

Страница 7: ...second The 2nd B channel is connected speech transfer chargeable time is running for a second connection Layer 1 The Telecom provider offers the service Layer 1 monitoring for the Point to multipoint...

Страница 8: ...e interface The Intercom Server is connected to the ISDN Basic Rate Interface point to multipoint or point to point configuration see System Configuration on page 7 as only equipment This is the optim...

Страница 9: ...links to each G3 S0 I one ISDN Basic Rate Interface one speech links Layer 1 Monitoring should be activated for LED status indication see page 6 Requirements for Auto Dialler Mode Point to point confi...

Страница 10: ...m the Telecom provider or directly at the telephone Calling line identification restriction must be deactivated The MSN Multiple Subscriber Number is configured incorrectly configuration directly at t...

Страница 11: ...installed in the slots 1 to 14 In each housing GE 800 a maximum of 7 G8 S0 can be used G3 S0 I For a Intercom Server GE 300 an interface housing GEI 300 has to be used one GEI 300 per GE 300 the GEI 3...

Страница 12: ...d G8A C is connected directly to the NTBA no termination resistors are necessary but the line may not be longer than 10 m 32 8 ft 4 max 10 m 33 ft 3 4 5 6 7 1 8 2 100 Ohm 100 Ohm 100 Ohm 100 Ohm 2a 2a...

Страница 13: ...n to the other Intercom Ser ver housing is entered max 24 digits At Auto separating after sec the time after which the G8 S0 G3 S0 I hooks on after the call has been cancelled can be defined Minimum 3...

Страница 14: ...For G8 S0 G3 S0 I which are used for networking no telephone function must be activated for the respective card at Interfaces S0 Server ID Description Configuration for Target Intercom Server Target T...

Страница 15: ...com Server 2 1 10 20 3 30 20 4 40 20 Intercom Server 3 1 10 30 2 20 30 4 40 30 Intercom Server 4 1 10 40 2 20 40 3 30 40 Configuration for Target Intercom Server Target Tel No Reserved own Tel No Inte...

Страница 16: ...t Intercom Server Target Tel No Reserved own Tel No Intercom Server 1 2 20 10 3 30 10 4 40 10 5 50 11 Intercom Server 2 1 10 20 3 30 20 4 40 20 Intercom Server 3 1 10 30 2 20 30 4 40 30 Intercom Serve...

Страница 17: ...t or output numbers If you want to use 1 digit block numbers for the Intercom Server blocks please mind that most of the digits are reserved for functions That means all digits except 1 2 and 3 are re...

Страница 18: ...hy levels etc In standard all Intercom Servers are contained in Configuration Block 0 The settings for this confi guration block can be found at Intercom Server Block 00 It is possible to define a sep...

Страница 19: ...ing at a group configuration of direct dialling for the door station with number of the Intercom Server block e g 4 81983 for ringing at group 3 in Intercom Server block 81 with button 4 Alarm configu...

Страница 20: ...control desk are connected over S0 The central control desks B and C shall be able to transfer calls to central control desk A No call requests are defined between Intercom Server B and C Each time a...

Страница 21: ...Block 2 92 Intercom Server Block 1 90 at Interfaces Gx S0 1 GE 800 Controldesk system 90 at Intercom Server Block 00 General ICX 92 Configuration Sub Intercom Servers Configuration Block 99 at Interc...

Страница 22: ...r a number it is possible to appear in one dialling sequence several times Example Telephone numbers 1 123456 Guard 1 2 456789 Guard 2 3 0663 0815 Mobile Phone 1 4 0663 4711 Mobile Phone 2 In the dayt...

Страница 23: ...with X At the telephone the conversation is cancelled with or by hanging up Call number indication During call requests conversations and input messages the calling number of the Intercom station of t...

Страница 24: ...ling to an Intercom subscriber or selection of Same as outgoing At Waiting Time the time is entered after which the next telephone number of the sequence is dialled if the call is not accepted At Dial...

Страница 25: ...are activated by inputs to which e g a time switch can be connected For the inputs dialling simulation has to be configured with the following code XX9T99 and the number of the dialling sequence e g...

Страница 26: ...g configuration at Subscriber Direct Dialling Call Request Input Message The telephone interface has to be configured as central control desk at Subscriber Control Desks For the calling station a call...

Страница 27: ...n it is possible to feed in a separate Calm down message Feed in the message over a subscriber configured to Feed in Radio Conference e g channel 1 Subscriber Feed in Radio For all calling Intercom st...

Страница 28: ...veral telephone numbers with only one entry in CCT 800 see below This function is only available for max 4 digit telephone numbers PA codes max 4 digit see current version of the manual PRO 800 A dumm...

Страница 29: ...is established the cursor disappears and after dialling in the Intercom Server is possible e g conference 77 switches back to telephone dialling for 8 seconds Call Request in PABX Mode It is possible...

Страница 30: ...deactivated At Hang up after the time is entered after which the connection between telephone interface and telephone net is cancelled after cancelling the respective conversation with or X At Max ti...

Страница 31: ...g the interface manually after diallings on the tele phone can be enabled Interfaces S0 tab Common For the telephone interface over which the call to the telephone shall be set up the checkbox After D...

Страница 32: ...calling station a call request has to be configured to the telephone interface at Subscriber Call Request For a calling input an input message has to be configured to the telephone interface at Inputs...

Страница 33: ...rd in PABX mode 8 seconds after entry of the last digit of the respective telephone number the after dial mode is switched automatically from DTMF dialling to Intercom dialling i e possibility for aft...

Страница 34: ...Technical Support G8 S0 G3 S0 I 34 1 1 1010 Technical Support For more information about our products and services visit www software manuals com...

Отзывы: