Cable-Connection 

 

Introduction 

 
For the full version of this manual, please visit COMMAX online 

www.commax.com > Customer > Manual and download full manuals for installation and users.

 

 
Access Control IDentry-T65 User Manual 

http://www.commax.co.kr/boardnew/lib/downfile.php?db=TB_ENGLISH_manual&fnum=153 

Access Control IDentry-T65 Installation Manual 

http://www.commax.co.kr/boardnew/lib/downfile.php?db=TB_ENGLISH_manual&fnum=121 

Access Control IDentry-CAMS-S User Manual 

http://www.commax.co.kr/boardnew/lib/downfile.php?db=TB_ENGLISH_manual&fnum=133 

 

 

 

 

 

1.

Power: 

Part ⑤ connects with DC12V and GND. It doesn’t matter the direction of the 

GND and VCC. 

2.

Extension Phone

: Part ⑥ connects with extension phone and the direction doesn’t 

matter. To communicate with extension phone, press # button and extension phone 
number . It is possible to control speaker volume using part ⑧ and Mic volume using 
part ⑨. 

 

 

 

Component 

Quantity 

T65 

Bracket 

Cable 

4(Input:9PIN/Relay:6PIN/Reader:5PIN/Power,485:4PIN) 

Screw  

Bracket: 4(T3x20mm)/ Reader: 2(M3x6mm) 

①Relay 1,2

: Connects with door lock and alarm devices 

②Card Reader

: Connects with external card reader 

③Sensor Input

: Connects with various sensors (door contact, alarm 

sensor etc) and exit button 

④Wiegand Output

: Outputs CARD datal 

(Used when it is integrated with other main controller) 

⑤Power Input/ RS 485

: Outputs CARD data 

(Used when it is integrated with other main controller) 

⑥TEL-LINE

: Connects with Extension Phone 

⑦TCP/IP Connector

: Communicate TCP/IP with PC 

⑧ Controls speaker volume 
⑨ Controls Mic volume 

IDentry-T65  