background image

7. Configuring Building and Serial Numbers in the Main

Entrance Interphone 

13

P-Management PIN - E - 2 - E - Serial Number - E

1. Press the Program button (P). ( 'Prog' will appear) 

2. Enter the Management PIN. 

3. Press the Call button (E). 

4. Press the Program Number (2)   . 

5. Press the Call button (E). (The Serial Number previously entered will be indicated) 

6. Enter the new Serial Number. 

7. Press the Call button 

Serial Number has been updated. 

Press the Program button (P).

Enter the Management PIN.

Press the Call button (E).

Press the Program Number(2).

Press the Call button (E).
The Serial Number previously
entered will be indicated

Enter the New Serial Number EX)101

Press the Call button.(E)

Serial Number has been updated.

Содержание DRC-900LC

Страница 1: ...dents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not responsible for any safety accidents caused by abnormal operation of the product Anti Vandal lobby phone DRC 900LC RF1 User Manual Feature Co...

Страница 2: ...4 Video Out Impedance Adjustment 25 15 InputHousehold number 26 16 A Talk volume control 28 17 How to set the button lighting 29 18 Paging the Household 30 19 Paging the Guard Station 30 20 Door Release Using the Household PIN 31 21 Door Release Using the Building Management PIN 31 22 How to use lobby phone 32 23 Appendix Various Program Summaries 33 24 Wiring Method 34 25 Miscellaneous 35 26 Part...

Страница 3: ...y or it may cause an electric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it for a long period of time It may shorten the product lifespan or cause a fire Please don t install the product in the place where there is much oil smoke or humidity It may caus...

Страница 4: ...he power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the designated connection cable within the maximum calling distance designated for the product It may reduce the product performance Please check the use voltage and current for the DC only products and u...

Страница 5: ...Description 1 Camera 2 Speaker 3 FND Display 4 RF ID 5 Dial button 6 Microphone 7 Program button 8 Electronic key button 9 Guard button 10 Cancel button 11 Call button 12 Wiring connection terminal 13 Reset switch 14 Switchgear connection terminal ...

Страница 6: ...n the Electronic Key option has been set as OFF When it is set as ON Finger Print Recognition is enabled Guard callt button G Guard This function is to call the guard house If the Management PIN can not be remembered press the Reset button Cancel Button X Cancel This button is used to cancel the current operation Reset Button This button is used to reset the Building PIN or the Management PIN ...

Страница 7: ...6 Change the message on FND To change the message on FND press the Program button P for 5 seconds 1 Displaying system version 0101 9901 SLI DRC 900L Ver 1 1 2 Displaying general message hELLo hAPPy dAy ...

Страница 8: ...PIN Please inquire to the Guard Station or the Management Office 2 2 Building PIN Reenter using the Management PIN 2 3 Management PIN Press the Reset button Both the Building and the Management Building PINs are reset to default 3 All Remote Cardkey Deletion is to be used only when the unit is being initially installed 4 Configuration Mode Indications Configured features are displayed on the Displ...

Страница 9: ...e common PIN for each main entrance By default this PIN is set as 1234 For convenience hereafter management PIN 4 3 Household PIN Each household has its own PIN By default this PIN is set as 1234 For convenience hereafter management PIN Reference P Program K Electronic Key E Call Old PIN Default Management PIN 4321 Default Building PIN 1234 Default Household PIN 1234 New PIN New PIN to be set by t...

Страница 10: ...utton P Prog will appear 2 Enter the old PIN 4321 3 Press the Call button E 4 Press the Program Number 0 5 Press the Call button E PASS will blink 6 Enter the new PIN 7 Press the Call button E 8 Management PIN has been updated Press the Program button P Press the Call button E Management PIN has been updated Enter the new PIN Ex 1470 Enter the old PIN 4321 Press the Call button E Press the Program...

Страница 11: ...old PIN 4321 3 Press the Call button E 4 Press the Program Number 1 5 Press the Call button E PASS will blink 6 Enter the new PIN 7 Press the Call button E 8 Building PIN has been updated Press the Program Number 1 Press the Call button E Building PIN has been updated Enter the new PIN Ex 2580 Press the Call button E 4 3 2 1 Press the Program button P Enter the old PIN 4321 Press the Call button E...

Страница 12: ...c Key button K 2 Press the Program Number 20 3 Press the Call button E hono will blink 4 Enter the Household Number 5 Press the Call button E PASS will blink 6 Enter the old Household PIN 7 Press the Call button E PASS will blink 8 Enter the new Household PIN 9 Press the Program button P Household PIN has been updated Electronic Key button K Household Number Ex 101 Press the Program Number 20 Pres...

Страница 13: ...E Household Number Ex 101 Press the Call button E Ex 1 2 3 4 for household 101 Enter the Management PIN Press the Call button E 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Press the Program Number 16 5 Press the Call button E hono will blink 6 Enter the Household Number Ex 101 7 Press the Call button E The Household PIN will be indicated ...

Страница 14: ...r 2 5 Press the Call button E The Serial Number previously entered will be indicated 6 Enter the new Serial Number 7 Press the Call button Serial Number has been updated Press the Program button P Enter the Management PIN Press the Call button E Press the Program Number 2 Press the Call button E The Serial Number previously entered will be indicated Enter the New Serial Number EX 101 Press the Cal...

Страница 15: ...Press the Call button E Press the Call button E The Serial Number previously entered will be indicated Press the Call button E 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Press the Program Number 3 5 Press the Call button E The Serial Number previously entered will be indicated 6 Enter the new Serial Number 7 Press the Call button Serial Num...

Страница 16: ... to the RF ID Receptor and the Card Number will appear on the Display Window FND 7 Press the Cancel button X to end Remote Cardkey testing Press the Program button P Enter the Building Management PIN Press the Call button E Press the Program Number 9 Press the Call button E Press the Cancel button X to end Remote Cardkey testing Press the Card Here ex Card Number 3579 Place the Remote Cardkey to t...

Страница 17: ...n t register a card please delete all saved card referring to 8 5 chapter Caution Do not turn off the products within ten seconds after registering RF cards It might cause a problem in saving RF cards information Press the Program button P Enter the Building Management PIN ex Building PIN Press the Call button E Press the Program Number 10 Press the Call button E Press the Cancel button X to end R...

Страница 18: ...n the right side of the RF ID Card Or place the Card on top of the RF ID Receiver 7 Press the Cancel button X to terminate the feature Press the Program button P Enter the Building Management PIN ex Building PIN Press the Call button E Press the Program Number 12 Press the Call button E Press the Cancel button X to terminate the feature Press the Card Here 1 Place the Card on top of the RF ID Rece...

Страница 19: ...side of the RF ID Card Or place the Card on top of the RF ID Receiver 7 Press the Cancel button X to terminate the feature Press the Program button P Enter the Building Management PIN ex Building PIN Press the Call button E Press the Call button E Press the Program Number 13 Press the Cancel button X to terminate the feature Press the Card Here 1 Place the Card on top of the RF ID Receiver and wil...

Страница 20: ...n E 4 Enter number 11 All Remote Cardkey Delete Number 5 Press the Call button E dEL will blink 6 Press the Call button E again The number displayed on screen will change 7 Press the Cancel button X to terminate the feature Press the Program button P Enter the Building Management PIN ex Building PIN Press the Call button E Press the Call button E All Remote Cardkey mode All Remote Cardkey mode Pre...

Страница 21: ...activate electronic key Activate electronic key Completion of activating electronic key Enter the Management PIN Press the Call button E Press the Call button E Previous selection is displayed 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Enter number 8 Monitor setting number for surveillance 5 Press the Call button E Displaying previous setti...

Страница 22: ...on is displayed Press the Call button E Press the Program Number 4 Press the Call button E Enter the Management PIN Press the Program button P 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Press number 4 Door Release Time Setup 5 Press the Call button E Previous selection is displayed 6 Choose a time From 1 to 25 seconds Use numbers from 1 to ...

Страница 23: ...n is displayed Press the Call button E Press the Program Number 21 Press the Call button E Enter the Management PIN Press the Program button P 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Press number 21 5 Press the Call button E Previous selection is displayed 6 Choose a line you want to call ex In case of calling to 1sthouse to 3rd house li...

Страница 24: ...t line The current capacity is displayed Press the Program Number 5 Press the Call button E Press the Call button E Press the Program button P Enter the Management PIN Ex Building PIN 1 Press the Program button P Prog will appear 2 Enter the Building Management PIN 3 Press the Call button E 4 Press number 5 Page Signal Selection 5 Press the Call button E Previous selection is displayed 6 Select a ...

Страница 25: ...he Call button E The current capacity is displayed Press the Call button E Enter the Management PIN Ex Building PIN Press the Program button P Completion of setup 0 Constant call 1 Call once 1 Press the Program button P Prog will appear 2 Enter the Management PIN 3 Press the Call button E 4 Press number 7 Wiring Method Selection 5 Press the Call button E Previous selection is displayed 6 Select a ...

Страница 26: ...ton E ex Impedance Adjusted long distance Select a Impedance Press the Program Number 6 Press the Call button E The current capacity is displayed Press the Call button E Press the Program button P 1 Press the Program button P Prog will appear 2 Enter the Building Management PIN 3 Press the Call button E 4 Press number 6 Wiring Method Selection 5 Press the Call button E Previous selection is displa...

Страница 27: ...N Entry Mode Lift up the receiver from the Household and press the Guard button to page the Main Entrance Interphone where the Household Number will be displayed Then the displayed number must be changed for it is the default number from the factory ex Entering as first 1234 Enter the Household number and press the Program button Ex Entering as Unit 101 Enter the Multi Sub number 0 and press the P...

Страница 28: ...Press the Page button E idCh will appear 6 Call to guard station from household 7 The Household s status is shownon the displaywindow FND 8 Household Number then press the Page button E sub willappear 9 Input Multi sub number 0 then press the Call button E 10 To check other Households repeat steps 6 9 Press theCancel button X to terminate the feature ...

Страница 29: ...ess the Call button E Press the Program Number 28 Press the Call button E Press the Call button E Press the Program button P 1 Press the program button Prog word will appear 2 Enter the administration password 3 Press the call button E 4 Enter no 28 the number to control the speaker volume 5 Press the call button E The value of the speaker volume already inputted will appear 6 Enter the value of t...

Страница 30: ...n case of settingthe lighting condition ON all the time Enter the Management PIN Complete to set the speaker volume Press the Program Number 27 Press the Call button E Press the Call button E Press the Program button P 1 Press program P button Prog will be turned on 2 Enter the administration password 3 Press the call E button 4 Enter No 27 button Button for light control 5 Press the call E button...

Страница 31: ...ousehold Number Ex unit 101 Press the page button A paging tone will sound Wait for a reply Start to conversation Press the Guard button Press the Page button A paging tone will sound Press the Call button E Wait for reply Start to conversation Press the Call button E ...

Страница 32: ...nter the Household Number Ex To open the door of unit 101 Press the Electronic key button Enter the Household PIN Press the Page button Press the Call button E Press the Guard button Press the Electronic key button G K Building Management PIN E Enter the Building or the Management PIN Press the Call button E Press the Page button ...

Страница 33: ...usehold PIN ex In case of household 101 ex In case of household 101 Press the Call button Press the Key button Press the Call button Emit call sounds Calling to household from lobby phone Household number E Opening door with household PIN Household number K household PIN E Press the Call button E ...

Страница 34: ...bers from the Main Entrance Interphone 1 P Management PIN E 2 E Building Number E Building Number Setup 2 P Management PIN E 3 E Serial Number E Serial Number Setup Door Release Using Various PINs 1 G K Building Management PIN E Door release using Building Management PIN 2 Household Number K Household PIN E Door release using Household PIN Other Feature Setup Methods 1 P Management PIN E 4 E Door ...

Страница 35: ...34 24 Wiring Method Lobby camera phone DRC 900LC ...

Страница 36: ...Flush Mounted Model Name DRC 900LC RF1 Transmission System Household 8 wire Guard 4 wire Rated Voltage 12V 0 5A Power Consumption Standby 200mA Max 500mA Conversation Hands free Frequency 15 735KHz 60Hz 15 625KHz 50Hz Camera C MOS Pin Hole type Effective Viewing Angle Horizontal 47 Vertical 34 Minimum Illumination 0 1Lux Within 300 mm from the camera Distance UTP cable 300meter Bulit in light LED ...

Страница 37: ...36 Memo ...

Страница 38: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2014 01 104 PM10900LCR10 ...

Отзывы: