background image

60

System schematic

(1) Using Coax Cable

Reference

Guard Talk line(common 8 wires)    

Lobby Talk line(common 4 wires)

External Talk line(common 18 wires) 

External Talk extension line(common 16 wires) ← Optional

Содержание DRC-703LC/RF1

Страница 1: ...sponsible for any safety accidents caused by abnormal operation of the product Thank you for purchasing COMMAX products Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly The company is not responsible for any safety accidents caused by abnormal operation of the product Lobby Camera Phone DRC 703LC RF...

Страница 2: ...dance Adjustment Setting 36 22 Registration of Household Unit Number 37 23 Checking Videophone Status of Household Units 39 24 Setting the Keypad LED Option 41 25 Activation of Electronic Key Password Function 42 26 Setting the Volume of Voice and Beep Sound 43 27 Setting the Voice announcement of unit number function 44 28 The setting of Video call function 45 29 Setting the door release by build...

Страница 3: ...tric shock fire when using a damaged power cable Please don t handle the power cable with a wet hand It may cause an electric shock Please plug out the power cable from the socket when not using it for a long period of time It may shorten the product lifespan or cause a fire Please don t install the product in the place where there is much oil smoke or humidity It may cause an electric shock or fi...

Страница 4: ...he power cable Please don t use any chemical products such as wax benzene alcohol or cleanser Please don t drop the product on the ground and don t apply a shock It may cause a failure Please use the designated connection cable within the maximum calling distance designated for the product It may reduce the product performance Please check the use voltage and current for the DC only products and u...

Страница 5: ...thod Any short circuits and or disconnection may cause product damage Please check the wires before installation It is recommended to install one each of Lobby phone Security Station phone and Household unit monitor to check the functionality before initiating overall products installations RF Card Keys may be registered up to 2 048 keys if not connected to computer Failing Management Password Bui...

Страница 6: ...Button n o i t c n u f r o s s e c o r p a l e c n a c o t being progressed 4 Microphone 12 Speaker 5 Lighting Black White IR LED Color White LED 13 Camera Angle Adjustment 6 Number Key Button 14 Reset Switch to reset building management password 7 Electronic Key Button for an access by password 15 Wiring Connection Terminal 8 Security Paging Button to page security station when interphone install...

Страница 7: ... on RF Receiver Optional For an access by RF Card when RF Card is brought nearby the LCD display shows a message Open Lobby with an icon and the door is open Program Button P Porgram To access the program Call Button E Enter To call a household unit ...

Страница 8: ...t the security center Cancel Button X Cancel To cancel a process or function being progressed Reset Button To reset the password for security center or managing office If the Building Password 4 2 or Management Password 4 1 is lost press the Reset Button located on the back of the product to reset the Password Passwords will be set as factory default settings Press the button for 3 seconds with po...

Страница 9: ...sented If you press the program button or guard button page will move on to next page Please read below instructions before use 1 If you hear beep beep beep during any program modes please restart from the beginning The beep sounds for improper process 2 If password is forgotten 2 1 Password for any household Use the identifying household password function 6 1 to confirm the password to confirm pa...

Страница 10: ...d for the Manager Factory default for the Manager Password is 4321 4 2 Password for any buildings Building Password A common password for a corresponding building Factory default for the Building Password is 1234 4 3 Password for any household units Unit Password A password for each household unit can be set Factory default for the Unit Password is 1234 Reference P Program Button K Electronic Key ...

Страница 11: ...y recommended 5 1 Press management Password P old Password E 0 E New Password E Password must be 4 digits 0000 1234 4321 can t be used as Password Press program button P Press old management default Password 4 3 2 1 Press call button E Press 0 Press call button E Press new Password Press call button E Management Password has been changed ...

Страница 12: ...word E Password must be 4 digits 0000 1234 4321 can t be used as Password Press program button P Press old building default Password 4 3 2 1 Press call button E Press 1 Press call button E Press new Password Press call button E Building Password has been changed ...

Страница 13: ...word no may not be changed because of Interphone types Some model of Interphone can change Password in house Please check manual of interphone Press program button K Press 20 Press call button E Press house Number Press call button E Press old house Password 4 3 2 1 Press call button E Press new house Password Press call button E House Password has been changed ...

Страница 14: ...Check house Password P management Password E 16 E Household Unit Number E Press program button P Press management Password Press call button E Press 16 Press call button E Press new ID Number Press call button E Press call button E ...

Страница 15: ...l house and security guard Max 99 lobby panel can be installed for one building 7 1 Set building Number in Lobby panel interphone P Management Password E 2 E Building Number E Press program button P Press management Password Press call button E Press 2 Press call button E Press new building Number Press call button E Building Number has been changed ...

Страница 16: ... no in Lobby Panel P Management Password E 3 E ID E Press program button P Press management Password Press call button E Press 3 Press call button E Press new ID Number Press call button E ID Number has been changed ...

Страница 17: ... This function is only for the test of wireless card key Press down the P button Press Management Passwords Press Call Button E Press number 9 Press Call Button E The card registration number will be on LCD when the card key is close to the RF ID receiver Press down the X button for finish after test ...

Страница 18: ...17 References Up to 2048 cards can be registered if not to connect with SecuMAX 8 2 RF card key input way P Management Password E 10 E Place card close to the RF ID receiver X cancel ...

Страница 19: ...t Password E 12 E Delete cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 Press Call Button E Place the card key close to the RF ID receiver Press down the X to finish when separate deletion is completed ...

Страница 20: ...Identification number E X Cancel Press Program Button P Press Management Password Press Call Button E Press number 12 Press Call Button E Input the identification number you want to delete Press Call Button E Press down the X to finish when separate deletion is completed ...

Страница 21: ...ment password E 13 E Check the cards X Cancel Press Program Button P Press Management Password Press Call Button E Press number 13 Press Call Button E Place the card key close to the RF ID receiver Press down X button to finish when check is completed ...

Страница 22: ...tered cards are to be deleted Press down P button Press Management Password Press down E button Press number 11 Press Call Button E Press Call Button E one more Press down X button if to cancel References All numbers can be deleted only if the mode 1 in the program number 23 is selected executed the all delete process within 30 seconds ...

Страница 23: ...t password E 19 E 1 E Unlimited RF Cards can be registered Press down P button Press Management Password Press down E button Press number 19 Press Call Button E Select mode between numbers 0 and 1 0 Up to 2048 RF Card Keys can be registered 1 Unlimited RF Card Keys can be registered along with SecuMAX Press Call Button E ...

Страница 24: ... E Press number 32 Press Call Button E Press number source lobby phone number Press Call Button E References Data can be received only if the mode 99 in the program number 23 is selected executed the process within 30 seconds You cannot use any other function before it completes It takes about 5 minutes If you want to complete more quickly use the download program ...

Страница 25: ... call number Press Program Button P Press Management Passwords Press Call Button E Press number 4 Program Number Press Call Button E Enter the Household number Press Call Button E If you want to set other direct Call number Press the extension panel button you want to set Press down the X Button for finish after setting ...

Страница 26: ...rd E 22 E 1 E Forwarding to SecuMAX enabled This function is to set the door release by internal sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press number 22 Press Call Button E Select the mode 0 Forwarding to SecuMAX disabled 1 Forwarding to SecuMAX enabled Press Call Button E ...

Страница 27: ...e door opening hours Press Program Button P Press Management Passwords Press Call Button E Press number 5 Press Call Button E Select door opening hours Opening hours is in the middle of 1 25 seconds Press down any number for setting of door opening hours between 0 25 seconds Press Call Button E Changed opening hours is input ...

Страница 28: ... line ex In case 1 line 2 line input 0102 This function is only for specified line call not for entire house call Press Program Button P Press Management Passwords Press Call Button E Press number 21 for call line by line Press Call Button E Select the line for call ex If to call only from 1 line to 3 line Press 0103 Press Call Button E Changed setting would be input ...

Страница 29: ... E 1 E Emergency call mode This function is to set the automatic calling to the security station when the failure of Password occurs more than 3 times Press Program Button P Press Management Passwords Press Call Button E for call Press number 27 Press Call Button E Select the mode 0 Automatic call mode 1 Emergency call mode Press Call Button E ...

Страница 30: ...This function is to set the recall sound of house guard station at the common entrance Press Program Button P Press Management Passwords Press Call Button E for call Press number 7 for selection of call tones Press Call Button E Select the mode 0 Melody sound 1 Bell sound Press Call Button E Changed call tones will be set ...

Страница 31: ... 25 E 1 E 1 time Call ring enabled This function sets number of call ring repetition when a call is made to any households or security office Press Program Button P Press Management Password Press Call Button E Press 25 number twenty five Press Call Button E Select the mode 0 Continuous call ring 1 1 time call ring Press Call Button E ...

Страница 32: ... Password E 26 E 1 E Voice message disabled This function enables disables the Voice Message Function of DRC 703LC RF1 Press Program Button P Press Management Passwords Press Call Button E for call Press number 26 Press Call Button E Select the mode 0 Voice message enabled 1 Voice message disabled Press Call Button E ...

Страница 33: ... E Forwarding to SecuMAX enabled This function is to set door release by external sensor information forwarding to SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press number 18 for forwarding to SecuMAX Press Call Button E Select the mode 0 Forwarding to SecuMAX disabled 1 Forwarding to SecuMAX enabled Press Call Button E ...

Страница 34: ...d E 29 E 1 E Forced opening by SecuMAX enabled This function is to set the opening the Main Entrance door forced opening by SecuMAX Press Program Button P Press Management Passwords Press Call Button E for call Press number 29 Press Call Button E Select the mode 0 Forced opening by SecuMAX disabled 1 Forced opening by SecuMAX enabled Press Call Button E ...

Страница 35: ...to trigger the notice to be forced door forwarding to SecuMAX If you use this function you should set the time more 1 second than the door close time The notice forwarding to SecuMAX after 2 seconds when to be forced opening Press Program Button P Press Management Passwords Press Call Button E for call Press number 24 Press Call Button E Select the mode 0 This function is disabled 1 Set the time 1...

Страница 36: ...sword E 6 E 8 E common 8 wire method If common 8 wire method selected there will be no video signal sent to all household units Press Program Button P Press Management Password Press Call Button E Press 6 Press Call Button E Select the wiring method by Pressing number 1 Gateview method UTP 4 Common 4 Wire Method 8 Common 6 Wire Method Press Call Button E ...

Страница 37: ...nt Password E 8 E 1 E Long distance transmission Factory default is set as short distance transmission Press Program Button P Press Management Password Press Call Button E Press 8 Press Call Button E Select the transmission distance option between numbers 0 and 1 0 Short distance 1 Long distance Press Call Button E ...

Страница 38: ...E Call Security from the monitor number of household E serial number E This method applies to the case that there is no security station installed Calling security from the monitor will direct the call to the lobby phone Household Unit Number can be set at the lobby phone ...

Страница 39: ... registered As unit number registration is done press Cancel Button X to exit References Master videophone s Multi Sub Number is number 0 zero Sub videophone s Multi Sub Number is given between 1 and 4 Up to 4 videophones can be installed in a single household unit and the Multi Sub Numbers shall not be overlapped Multi Sub Numbers for sub videophones shall be registered in numerical order At leas...

Страница 40: ...39 23 Checking Videophone Status of Household Units P Management password E 14 Unit Number E serial number E This function is to check the status of videophones installed in each household unit ...

Страница 41: ...unit status repeat procedures As the status check is done press Cancel Button X to exit Status of household unit indication Standby standby mode applies even when the household unit monitor is communicating with an individual door phone of the unit or via telephone line Busy Line Busy mode applies when the household unit monitor is communicating with another household unit or security station Away...

Страница 42: ... function to set keypad LED ON OFF Press the program button P Please set up the Management password Press the call button E Press number 35 Press the call button E Select mode by numbers 0 or 1 0 White keypad LED light only work when you used lobby phone 1 White keypad LED light always on Press the call button E It will be changed ...

Страница 43: ...d P Management Password E 31 0 E Electronic Key Password disabled This function is to enable or disable the password access Press Program Button P Press Management Password Press Call Button E Press 31 Press Call Button E Select mode between numbers 0 and 1 1 Password enabled 0 Password disabled Press Call Button E ...

Страница 44: ...his function enables the adjustment of Beep Voice volume Press Program Button P Press Management Password Press Call Button E Press 30 Press Call Button E Press desirable Beep Volume 1 2 and then desirable Voice Volume 1 7 Press Call Button E References Beep sound volume applies to paging tone and button sound tone ...

Страница 45: ...cement of unit number disabled This function enables to select whether the voice announcement of unit number to be announced or not Press Program Button P Press Management Password Press Call Button E Press 17 Press Call Button E Select mode between the numbers 0 and 1 0 Voice announcement of unit number enabled 1 Voice announcement of unit number disabled Press Call Button E ...

Страница 46: ...ting of Video call function P Management Password E 36 E 0 E video call disabled P Management Password E 36 E 1 E video call enabled This function is to set the LCD the use of video call when the household is called ...

Страница 47: ...g is completed after the save Set by 1 it enters to LCD setting mode LCD settings each setting can be controlled with an each button of KEY PAD when the set screen is popped up as below 1 reset screen in LCD set mode A Brightness UP DOWN 1 7 Button B light Darkness UP DOWN 2 8 Button C Color UP DOWN 3 9 Button D Reset Settings 4 Brightness 5 Light Darkness 6 Color E Reset all settings 0 2 Press th...

Страница 48: ...sword enabled P Management Password E 28 0 E Door release by Building Password disabled This function enables the door release by Building Password This function provides least security to the access of the entrance since the password is being shared among number of people Please keep the security of Building Password strictly and or change the Building Password periodically ...

Страница 49: ... Button E Enter 28 number twenty eight Press Call Button E Select mode between the numbers 0 and 1 1 Door release by Building Password enabled 0 Door release by Building Password disabled Press Call Button E 29 2 Using a door release by Building Password function ...

Страница 50: ...r is installed and set You may set availability for DTMF when a floor distributor for audio is installed and set Please refer to our manual for floor distributor for your reference This function works only for version 3 0 or above Reference The function may work only when you set mode 99 on program no 23 and have it perform in 30 seconds Do not disturb the device while uploading or downloading dat...

Страница 51: ... DTMF off on unit number password Move onto next item by pressing guard button In case of audio floor distributors Axx will be indicated instead of Mxx lobby number you can set up 01 DTMF on available or 00 DTMF off not available from xx of Axx Input new information in a chosen item Any update for items would be allowed by going over process No 8 above again Upload new information onto the floor d...

Страница 52: ...51 31 When you want to call a household 1 called to a household 2 Call by Extension panel button ...

Страница 53: ...52 32 When you want to call a Guard Station 33 Door Release by Unit Password 1 Door release to a household ...

Страница 54: ...53 2 Door release by Extension panel button ...

Страница 55: ...54 34 Door Release by Building Password or Management Password ...

Страница 56: ... Release Function enabled disabled 00 Disabled 01 Enabled 4 P Management Password E 31 E Electronic Key Password enabled disabled 00 Disabled 01 Enabled RF Card Key Programming 1 P Management Password E 9 E RF Card Key Testing 2 P Management Password E 10 E RF Card Key Registration 3 P Management Password E 11 E All RF Card Keys Initialization 4 P Management Password E 12 E Deletion an individual ...

Страница 57: ...er 00 enabled 01 disabled 7 P Management Password E 21 E Setting the Call by Unit Line 8 P Management Password E 24 E Setting the Forced Entry Notice Forwarding Function 9 P Management Password E 25 E Setting number of Call Rings 00 continuous 01 once 10 P Management Password E 26 E Setting the Voice Message Function 00 enabled 01 disabled 11 P Management Password E 27 E Setting the Automatic Secu...

Страница 58: ...57 36 Wiring Information Guard interphone 1 GateView Guard Station 2 481 Guard Station ...

Страница 59: ...58 entrance interphone DRC 703LC RF1 1 Using Coax Cable ...

Страница 60: ...59 2 Using UTP Cat 5e Cable Caution 1 If installed outdoor it requires extra molding for water proof and rainshield 2 Recommanded height is pertinent from 1450mm 1500mm ...

Страница 61: ...System schematic 1 Using Coax Cable Reference ⓐ Guard Talk line common 8 wires ⓑ Lobby Talk line common 4 wires ⓒ External Talk line common 18 wires ⓓ External Talk extension line common 16 wires Optional ...

Страница 62: ...61 2 Using UTP Cat 5e Cable ...

Страница 63: ...62 Wiring Method for CCTV and Sensor Connection ...

Страница 64: ...on Precautions 1 Assemble speaker grill at last stage of installing the product Assemble from left then fasten screw on the right side to finish 2 When installing the product outside the building make sure the product s sides and edges are waterproof molded with silicon or other materials ...

Страница 65: ...Part list Please carefully read this User s Guide before calling service man After checking the entire check list please contact customer service center We will do our best to make you satisfy with our services 1 Using Coax Cable Item Description Q ty CONN 2PX300 Wiring Connector 2 CONN 3P 3 96 X250 Wiring Connector 1 CONN 3PX300 Wiring Connector 2 CONN 4PX300 Wiring Connector 2 CONN 10PX300 Wirin...

Страница 66: ...mperature 20 C tested up to 40 C 50 C Dimensions 244 W x 270 H x 46 D mm Wiring Effective Call Range Using Coax cable Household com 4wires Guard com 8 wires 3C2V 200m 5C2V 300m 7C2V 500m UTPCAT 5e 300m Using UTP Cat 5e cable Household 8 wires com 6w VD 2w Guard com 4wires 0 3 Lux up to 300mm from the camera 41 RF ID Model Optional Model Name DRC 703LC RF1 Frequency 13 56MHz Antenna power range Und...

Страница 67: ...66 Memo ...

Страница 68: ...513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2016 03 104 PM10703LCR10 ...