38
①
Press Program Button "P".
②
Press Management password.
③
Press Call Button "E".
④
Press "15"
⑤
Press Call Button "E".
⑥
From a household unit, call security. The factory default household unit number appears
on the LCD display of the lobby phone. Please Press the actual unit number.
⑦
Press the actual unit number and press Call Button "E".
⑧
Press "0" (0 is Master lobby phone number. If multiple lobby phones are installed,
please Press the corresponding lobby phone number) and press Call Button "E".
⑨
On the LCD display, the unit number input mode appears.
⑩
By repeating
⑥
,
⑦
,
⑧
,
⑨
procedures, other unit numbers can be registered.
⑪
As unit number registration is done press Cancel Button "X" to exit.
<References>
•
Master-videophone's "Multi Sub Number" is number 0 (zero).
•
Sub-videophone's "Multi Sub Number" is given between 1 and 4.
•
Up to 4 videophones can be installed in a single household unit and the
"Multi Sub Numbers" shall not be overlapped.
•
"Multi Sub Numbers" for sub-videophones shall be registered in
numerical order.
•
At least one Master-videophone with "Multi Sub Number 0" must be
installed and if only one videophone is installed, it is considered as
Master-videophone (set as Multi Sub Number 0).
•
In case that ADT-481 is installed, it does not register as Master unit.
•
If sub-videophone is 485 system, its Master-videophone's Multi Sub
Number is 1 (one) and those of sub-videophones are between 2 and
59.
Содержание DRC-703LC/RF1
Страница 52: ...51 31 When you want to call a household 1 called to a household 2 Call by Extension panel button ...
Страница 53: ...52 32 When you want to call a Guard Station 33 Door Release by Unit Password 1 Door release to a household ...
Страница 54: ...53 2 Door release by Extension panel button ...
Страница 55: ...54 34 Door Release by Building Password or Management Password ...
Страница 58: ...57 36 Wiring Information Guard interphone 1 GateView Guard Station 2 481 Guard Station ...
Страница 59: ...58 entrance interphone DRC 703LC RF1 1 Using Coax Cable ...
Страница 62: ...61 2 Using UTP Cat 5e Cable ...
Страница 63: ...62 Wiring Method for CCTV and Sensor Connection ...
Страница 67: ...66 Memo ...