14. Setting the Call by Unit Line.
"
P" - Management Password - "E" - 21 (number twenty-one) - "E" - 0 (number zero) -
"E" : Calling all units enabled (not a simultaneous call).
"
P" - Management Password - "E" - 21 (number twenty-one) - "E" - Unit Line - "E" :
Calling only the registered unit line enabled.
- Unit Line 01 means all units end with number "1", i.e. Unit# 101,201, 301...1201.
- Unit Line 02 means all units end with number "2", i.e. Unit# 102, 202, 302...1202.
- Unit Line 1~2 means all units end with number "1" and "2". The input value will be
"0102" for setting.
This function is useful to limit the call access by the location of entrances.
①
Press Program Button "P".
②
Enter Management Password.
③
Press Call Button "E".
④
Enter "21" (number twenty-one).
⑤
Press Call Button "E".
⑥
Select Unit Line.
Ex. Enabling call from unit line 1 to unit line 3 is "0103".
⑦
Press Call Button "E".