background image

Component

Content

Specification

4

5

01

Specification

02

Part Name

03

How to Use

Sound Pause
Sound Adjustment
Auto/Manual Lock Setting
Smart key Auto/Manual setting
Multi-touch security setting

08
09
10
10
11
12
12
13

04

Convenient Function

(option)

14
14
15
15
16

05

Emergency Alam

17
17
18
18
19

06

Cause and Solution

20

05

06

01

Register/Change Password
Register/Change Smart Key
How to delete Smart Key
Open door from outside
Close door from outside
Open door from inside
Close door from inside
Compulsive Lock 

High Temperature Detection
Intrusion Alam
Wrong input prevention
Mortise trapping Alert
Battery Replacement Alarm

Digital Door Lock COMMAX 

Product Specification

Category

Installed at

Common Fire Door

Password

Smart Key

Door Open by

Power Source

DC 6V

Emergency Power

DC 9V

Product Category

Direct Current, Non fire-resistance type, Temperature Sensor, 

Non physical-key type, Sub key door lock (D-NF-T-NK-S)

Temperature

Detection

Temperature

Sensor type 

72°C ± 5°C (at Lab.)
62°C ± 5°C (at Site)

Materials

Al, Zn, ABS
Al, Zn, ABS

Spec.

RF Spec

Item

RFID

Frequency

13.56Mhz

Channels

1ea

Modulated by

ASK

Electric field strength

93.5dBuV/m@10m

Door Thickness 35mm ~ 50mm
4~12 digits (total 4 passwords registrable)
Less than 30 keys registrable.
LR6 1.5V AA size Alkaline battery (4ea)
Alkaline 9V battery (1ea)

Outdoor Body

Indoor Body

Outdoor Body

Indoor Body

Striker

Battery (4ea)

Screw

Warning Sticker

Installation Guide

User Guide

(inclu. Product Warrantee)

Smart Key (4ea)

Содержание CDL-1AR

Страница 1: ...2018 04 User Manual...

Страница 2: ...cking system It also has fire detection sensors checking the indoor temperature If temperature is out of normal and fire might be occurred doorlock is automatically unlocked Multiple Registration of p...

Страница 3: ...Digital Door Lock COMMAX Product Specification Category Installed at Common Fire Door Password Smart Key Door Open by Power Source DC 6V Emergency Power DC 9V Product Category Direct Current Non fire...

Страница 4: ...ith emergency sound when extremely low voltage 6 7 Digital Door Lock COMMAX Part name 02 Indoor Unit Dead bolt Auto door lock sensor Locking bolt to close the door Detecting the status of door open an...

Страница 5: ...nd at the outside of door Stand at the outside of the door Register Change Smart Key NOTE CAUTION CAUTION When registering or re registering a smart key you must register all the smart keys you have A...

Страница 6: ...d exposure you can use imaginary function Open door from the outside Smart phones and transportation cards T Money Cashbee with a transportation card function other than the provided smart key can be...

Страница 7: ...Opening the door by operating the INSTALLATION OPEN LOCK button on the indoor side releases the double lock setting Set up With close the door If you press the DOUBLE LOCK button of the indoor body f...

Страница 8: ...oduct for the first time it is set to Auto Lock When the manual lock is set the door is not locked even when the door is closed Press the Open Lock button or touch Plate of the outdoor body to lock th...

Страница 9: ...or body is exposed to direct sunlight for a long time the temperature sensor may be activated and a beep sound may be generated Internal double lock automatically unlocks the door Depending on the ins...

Страница 10: ...ional cost might be required If deadbolt of indoor body is not clamped correctly during door open or close 3 times of beep sound is ringing Battery replacement All batteries must be replaced with NEW...

Страница 11: ...oor though push button Please check passwor input correctly When input password keypad light off it will be not change password presss the button and check keypad light on input password again if didn...