5
floor.
●
Within max 300m, CCU-4GF should be used less than 40 units.
●
In CCU-4GF, the distance to the video phone of Gate View on the relevant floor
should be within 20m
●
CCU-4GF should be connected with the additional power. (More than
DC12V/500mA)
●
Power(DC12V / 500 mA) input is basically installed one power per one CCU-4GF.
But, if you attempt to use one power in common for the reason of installation, pay
attention not to exceed within 30m of max power line, max 5 of connection num-
ber.
●
As this equipment(CCU-4GF) is the floor distributor possible to be interlocked with
Gate View Lobby Phone[DRC-GAC/GAB], it won’t work normally while interlocking
with other extension equipment
(This product is not compatible with VD-103.If needed, use VD-103(N))