1
8
Ȅ
Notes
when use Lobby mode.
z
S/W1 : Set LOBBY mode
Î
SW1 “ON”.
z
S/W2 :
Set response of l
obby SECUMAX DATA
Î
SW2 “ON”.
¾
This is for the system without SECUMAX.
¾
I
n caes of
us
ing
CCU-310EV without SECUMAX,
lobby
’s SECUMAX DATA must be
set
“ON”.
Æ
CCU-310EV collects data which LOBBY informs
to
SECUMAX.
Also, it works when opening the door during calling between LOBBY and household.
¾
If no
intalled
SECUMAX., calling might
be
calling
problem due to lots of data stored
i
nto
the lobby
.
Î
If no SECUMAX., S/W2 must be “ON” to respond the data instead of SECUMAX.
z
S/W3, S/W4 : NONE USED
z
S/W5~S/W8 : CCU-310EV ID setting
- S/W5 (BIT3), S/W6 (BIT2), S/W7 (BIT1), S/W8 (BIT0)
- LOBBY MODE: ID1 ~ ID9 can be set.
Ex.) 10 LOBBY is set per
one
CCU-310EV. (Total of 90 units)
- DIP switch ID setting method : refer to “5-3-1. DIP switch setting method”.