4. User Setting
After Menu screen appears, you can change setting with below 4 buttons
Menu start and finish :[ ] (Menu button -‘[ ] ’)
SELECT : [ ] (Guard button-‘[ ] ’)
Move upward /move right : [
] (Door release button –‘▲’ / ‘
▶
’)
Move downward /move left : [ ] ( Monitor button–‘▼’ / ‘
◀
’)
After pressing MENU button in Video call or monitoring mode, you can change settings for
DOOR(LOBBY), VIDEO SET(BRIGHTNESS / CONTRAST/ COLOR), UTILITY (ADDITIONAL
FUNCTION) and INFORMATION (product information)
4-1.Display setting
DOOR(LOBBY) VIDEO SET (BRIGHTNESS / CONTRAST/ COLOR control function).
After moving to menu with MENU button, press SELECT button to move to the menu below.
(you can control LOBBY VIDEO SET while you are talking with lobby.)
(1)
BRIGHTNESS : control BRIGHTNESS
(2)
CONTRAST : control CONTRAST
(3)
COLOR : control COLOR
You can control from 0 to 20 level. Initial level is set for level 10
9
3-11. Interlocking with Digital Door Lock
This product can be interlocked with Digital Door Lock via RF module and please refer to connection
diagram.
3-
10
. Approximate alert function
①
In emergency situation, alert tone is generated and this is delivered to guard station
②
The message notification is delivered until household turns off the security mode
③
After notification, devices changes in to stand-by mode
Stand-by mode: pre-mode for ring tone alert. When you receive calls from exterior, device sends
alert tone rings to external devices. (lobby, etc.)
-
(1)
When sensor 2 detects gas release, security2
(Hospital alert tone)alert tone occurs at monitor and guard
station device
(2)
After checking alert situation is terminated, press away
button twice.
(One time: release/ two times: return), after return, front
LED blinking and security 2 alert tone stops
3-
9
. ALARM2(Gas) function