background image

8

9

8. Chime sound

Chime will sound when calling an individual door bell with audio type.

Note) The doors do not open by default password 

1234

Only after changing default Password, can you use this function

1) Initialization for the password

(only the password for the Master unit is initialized)

Shut off master unit and turn it on again while holding the 

extension call

button 

and 

Door release

button at the same time for 3 seconds at the same time.

The password will initialize to 

1234

when the blink of LED stops.  

Note : Default password : 1234

2) Changing Resident Password(From Multi Entry Panel)

Hold 

Residence Number

and 

button for 2 seconds 

and release when LCD stops blinking.

Enter 

Current password

.

Hold 

button for 2 seconds and release when LCD stops blinking.

Enter 

New Password

with 4 digits on Multi Entry Panel 

displaying 

NEW PW : 

message.

Hold 

button for 2 seconds and release when LCD stops blinking.

Repeat 

New password

to confirm it.

Hold 

button for 2 seconds and release when LCD stops blinking.

9. Changing and initialization of the password

Note) The doors do not open by default password 

1234

Only after changing default Password, can you use this function

1) Open the entrance with resident password

Press resident number

and 

button     

Press  PIN number and the 

button

- The door opens with the 

OPEN

message display on the LCD screen.

2) Open the entrance with Building password

Enter 

9900

and 

button

Enter the 

Building password

and the 

button

10. Opening the entrance of a Multi-entry Panel 

With Password

Then, register the ID of the said residence, 

and press 

button to hear a sound of completion.

The registration is complete when you hang up the handset.

(Repeat this process for other residentes)

Set the ID’ as “1” on the Multi-Entry panel after completing the registration

Содержание APV-4PM

Страница 1: ...his User s Guide in particular precautions for safety before using the product and follow the instructions to use your productexactly The company is not responsible for any safety accidents caused in...

Страница 2: ...g Intercommunication Guard station or external area calling Call Talk duration Setting In House unit as a Master and Sub Unite Chime sound Changing and initialization of the password Opening the entra...

Страница 3: ...ormal do not put the plug It may cause an electric shock or a fire Make sure that dust or foreign substances are not gathered on the product Make sure to prevent foreign substances from entering the p...

Страница 4: ...ALK2 DATA1 POWER1 VIDEO1 GND1 Power Voltage DC24V 28V 5A Master Supplied from floor Distributor Slave Extra power sourse is required Transmission Method Full duplex Screen Dimension 4 CRT Power requir...

Страница 5: ...et Repeat this process for other residentes Set the ID as 1 on the Multi Entry panel after completing the registration 3 Multi Entry Panel Calling Pick up the handset and press the extension call butt...

Страница 6: ...4 digits on Multi Entry Panel displaying NEW PW message Hold button for 2 seconds and release when LCD stops blinking Repeat New password to confirm it Hold button for 2 seconds and release when LCD...

Страница 7: ...AT 5 cable and be careful to match the color of the wires shown to the left The Power of the Master unit supplied from the Floor distributor without an additional power supply but additional sub units...

Страница 8: ...a513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Web site www commax com Printed In Korea 2007 10...

Отзывы: