Command Light CL605 Скачать руководство пользователя страница 15

USER GUIDE 

15 

 

 

 

Electrical Wiring 

Please Note: Detailed internal wiring schematic for the light is found in the supplement 
pages found at the end of this document. 

 

Run the control wire from the control box holster to the 

COMMAND LIGHT

 

Run the power wire from the breaker box or generator to the 

COMMAND LIGHT

 

Make the control connections in the 

COMMAND LIGHT 

entrance box. To simplify 

installation, remove the connector hold down screws and pull the connector out of the box 
slightly. 

 

The Model 605/607 series 

COMMAND LIGHT 

comes pre-wired to connect to 120 VAC.  

A 40 Amp breaker is recommended. 

 

The Model 611/615 series 

COMMAND LIGHT 

comes pre-wired to connect to 240 VAC.  

A 50 Amp breaker is recommended. 

 

120 VAC Wiring Diagram 

 

240 VAC Wiring Diagram 

If 240 VAC operation is desired, remove the jumper wire between the red and black leads. 

 

Содержание CL605

Страница 1: ...C LS e r i e s...

Страница 2: ...versatile flood lighting package available We take great pride in the quality of our work and hope that you will find many years of satisfaction from the use of this equipment Should you have any prob...

Страница 3: ...USER GUIDE 3...

Страница 4: ...aising the light from the nested position 10 Returning the light to the nested position 11 Installation 11 Installation Kit 11 Tools Required 12 Installation Notes 12 Location Requirements 13 Mounting...

Страница 5: ...View Lower Stage B 30 Upper Stage Parts List A 31 Exploded View Upper Stage A 32 Upper Stage Parts List B 33 Exploded View Upper Stage B 34 Upper Stage Parts List C 35 Exploded View Upper Stage C 36...

Страница 6: ...pped in good working order and condition We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase 1 This warranty d...

Страница 7: ...mponents come with their own manufacturer warranty Contact us and we can help get it Breakage or Damage During Shipment The transportation company is fully responsible for all shipping damage and will...

Страница 8: ...e light position while people are located within its operating envelope There are numerous pinch points that can cause serious bodily injury X Do not use a high pressure washer or subject the light to...

Страница 9: ...COMMAND LIGHT Model Description Minimum Power Requirements CL605 6 x 500 watts 3KW 110 or 240 VAC CL607 6 x 750 watts 5KW 110 or 240VAC CL611 6 x 1000 watts 6KW 240 VAC CL615 6 x 1500 watts 9KW 240 VA...

Страница 10: ...rride system that precludes rotation of the upper stage until the lower stage has elevated approximately 16 from the nested position When the lower stage is below 16 the following conditions exist Upp...

Страница 11: ...ns retracting Upon upper stage retracting fully Emergency Stop light turns off Controller will need to be re energized after Emergency Stop or nest is activated Installation The COMMAND LIGHT must be...

Страница 12: ...ector crimp tool Silicone based gasket sealer RTV recommended Installation Notes The COMMAND LIGHT weighs approximately 300 pounds Use mechanical assistance to lift the light into installation positio...

Страница 13: ...Make certain sufficient clearances are incorporatedin your installation to allow for variations vehicle body flex environmental conditions future servicing needs etc If your light is not represented...

Страница 14: ...tion above the spacers Before placing the full weight of the unit on the spacers align spacers with the holes in the end frame castings Drill 13 32 holes in the mounting surface using the end casting...

Страница 15: ...control connections in the COMMAND LIGHT entrance box To simplify installation remove the connector hold down screws and pull the connector out of the box slightly The Model 605 607 series COMMAND LIG...

Страница 16: ...elevated warning device will be used in conjunction with the light tower If a warning device will be used use the wiring diagram on the next page otherwise use the wiring diagram in the back of the us...

Страница 17: ...chematic will be used for V Mux or any other multiplex system if it is only being used for elevated warning A V Mux wiring schematic and circuit board troubleshooting guide are included Detaching Atta...

Страница 18: ...th alcohol Latch the bezel making sure that the weather stripping is properly fitted Weather stripping must be properly installed to ensure lamp water tightness Cleaning The COMMAND LIGHT is construct...

Страница 19: ...ove Once disconnected remove chain Note The upper lamp tree will now rotate freely 3 Using a 3 32 allen wrench Remove the two set screws in the small sprocket Gently pull off the small sprocket 4 Remo...

Страница 20: ...up the four motor screws to let the motor slip for adjustment Wrap the chain back around the sprockets bringing the ends together Note Be sure the half link is on the right hand side with the small c...

Страница 21: ...racket slightly 7 Tap center switch bracket slightly toward the side that the lamp tree is hitting on 8 Fully tighten the screws holding the center switch bracket 9 Raise lamp tree all the way up rota...

Страница 22: ...equires the least amount of travel in order to center the platform Retract The Lower Stage First Locate the silver plug located on lower actuator below the lower actuator s motor Use the provided hex...

Страница 23: ...tage green light illuminated Unit being operated on a slope 10 Lower upper stage to horizontal Using a pike pole hold unit level while lowering to nest position Autopark button must be held in to park...

Страница 24: ...COMMAND LIGHT 24...

Страница 25: ...bulbs 230 VAC 28 amps 6 kW minimum 1500 Watt bulbs 230 VAC 40 amps 10 kW minimum Lift actuators and rotation motor will cause higher current draw during use Motor Duty Cycle All motors thermally prot...

Страница 26: ...COMMAND LIGHT 26 Specifications...

Страница 27: ...USER GUIDE 27 Parts List Lower Stage...

Страница 28: ...28 COMMAND LIGHT Exploded View Lower Stage...

Страница 29: ...29 USER GUIDE Parts List Upper Stage...

Страница 30: ...30 COMMAND LIGHT Exploded View Upper Stage...

Страница 31: ...31 USER GUIDE Exploded View Parts Mid Plate...

Страница 32: ...32 COMMAND LIGHT Exploded View Parts Platform...

Страница 33: ...33 USER GUIDE Parts List Lamptree...

Страница 34: ...34 COMMAND LIGHT Exploded View Lamptree...

Страница 35: ...35 USER GUIDE Parts List Backlight...

Страница 36: ...36 COMMAND LIGHT Exploded View Backlight...

Страница 37: ...37 USER GUIDE Wiring Schematics Relay Box...

Страница 38: ...38 COMMAND LIGHT Entrance Box 120VAC...

Страница 39: ...39 USER GUIDE Entrance Box 220VAC...

Страница 40: ...40 COMMAND LIGHT Entrance Box 240VAC...

Страница 41: ...3 1 5 7 3 1 7 7 175 3 5 67 57 8 5281 2 5 32 5 2 5 5281 5281 21 25 86 7 200 1 7 02 7 9 7 51 1 1 725 9 77 287 723 7 1 0 7 1 2 5 7 1 200 1 7 72 7 72 5 7 17 5 287 2 3 5 7 7 5 B 7 5 28 0867 1 8 3 7 6 5 6 7...

Страница 42: ...7 5 2 27720 78 725 2 1 27720 78 725 83 723 78 725 2 1 723 78 725 83 3 1 5 7 3 1 7 7 175 3 5 67 57 8 5281 2 5 32 5 2 5 5281 5281 21 25 86 7 200 1 7 02 7 12 9 7 51 1 1 725 B 5 7 9 77 287 723 7 1 0 7 1 2...

Страница 43: ...43 USER GUIDE Control Wiring...

Страница 44: ...44 COMMAND LIGHT Lamp Tree Backlight...

Страница 45: ...45 USER GUIDE Lamp Tree Strobe...

Страница 46: ...46 COMMAND LIGHT 4MH...

Отзывы: