background image

Cylindrical housing

Slide the motor mount into the device. Feed the 

acme thread into the cylinder clockwise.

7.

Connect your 8’ lead (CAT retrofit) or you can remove 

the VD connector to hard wire take stripped wire end 

and push into the push & go connector.

9.

Hook up to power & set your PTS. 

11.

Slide the filler plate back on to re-install

12.

Continue feeding the acme thread until the holes on  

the motor mount line up to the existing dogging holes.  

Next, install the (2) screws provided.

8.

Next, plug in the push & go connector into 

the MM4S.

10.

Installation Instructions   

Setting PTS

Step 1-

Select your preferred torque mode (ships in standard torque) Press the device push pad to the 

desired setting. (Recommend to fully depress and release 5%, giving the device room for  

changing door conditions.)

Step 2-

 While depressing the push pad, apply power. (i.e. presenting the credential to the reader).

Step 3-

 Continue to keep pad depressed, the device will beep 6 times. After the beeps have 

stopped, release the pad and now the adjustment is complete. If not to your liking repeat 

the three steps. 

Step 4-

 Once you found the correct location, flip the dip switches to off to lock programming. 

# 2 0 0 9 2 _ F

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

mm4s switches

2

on
on

off

STANDARD TORQUE

HIGH TORQUE

PTS PROGRAMMING LOCKED

PTS PROGRAMMING on

off

1

Содержание CYLP-UL-M KIT

Страница 1: ...Cap A B C D E F G Cordless Drill 2 Phillips head screwdriver CYLP UL M KIT INSERT Instructions The Command Access CYLP UL M KIT is a field installable motorized latch pullback kit for the Corbin 4000 5000 Yale 7000 series devices INSTALL VIDEO 2 0 0 9 2 _ F U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 ...

Страница 2: ...n Current 1 Amp Average Holding Current 215 mA Standard Torque Mode SPECIFICATIONS Input Voltage 24VDC 10 Wire gauge Minimum 18 gauge Direct wire run no relays or access control units in between power supply module 2 Beeps 3 Beeps 5 Beeps 6 Beeps Beeps Explanation Solution Over Voltage Under Voltage Retraction or dogging Push to Start 30V unit will shut down Check voltage adjust to 24 V 20V unit w...

Страница 3: ...nd Access power supplies at our factory For more information click here or go to our website Retrofit 2 pin Connector The new 2 pin connector is used when retrofitting a older Command or Von Duprin installation so you can plug in to the existing connector PUSH N GO Connector New Exisitng STRIPE WIRE 1 8 3 16 7 INSERT INTO WIRE ACCESS HOLES OF CONNECTOR WIRE RELEASE WIRE ACCESS 2 0 0 9 2 _ F U S c ...

Страница 4: ...ecure the bracket to the device 5 Refer to this picture for the next 2 steps 4 Use the 2nd set screw to set the height of the attaching block You want the block to be level 6 If dogging assembly is present remove 2 screws and discard dogging assembly 2 2 0 0 9 2 _ F U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5...

Страница 5: ...hips in standard torque Press the device push pad to the desired setting Recommend to fully depress and release 5 giving the device room for changing door conditions Step 2 While depressing the push pad apply power i e presenting the credential to the reader Step 3 Continue to keep pad depressed the device will beep 6 times After the beeps have stopped release the pad and now the adjustment is com...

Отзывы: