background image

Ceiling Tile

Legend

Standard Placement

Module

GREEN 

CHANNEL 1 

LED

NORMALLY OPEN

DRY CONTACT FROM 

ACCESS CONTROL 

SYSTEM

NO VOLTAGE

LOCKING 

HARDWARE

+

-

CAT

Electrified Exit Device

INSTALLATION EXAMPLE

R

ecommended

 P

oweR

 S

uPPlieS

:

All Command Access exit devices & field installable kits have been thoroughly cycle 

tested with Command Access power supplies at our factory. 

For more information 

click here 

or go to our website

U S   c u s t o m e r   s u p p o r t   1 - 8 8 8 - 6 2 2 - 2 3 7 7   |   w w w. c o m m a n d a c c e s s . c o m   |   C A   c u s t o m e r   s u p p o r t   1 - 8 5 5 - 8 2 3 - 3 0 0 2

Содержание ARLP88-KIT

Страница 1: ...s a field installable solenoid latch pullback kit for the Adams Rite 8800 series devices 2 0 4 3 1 _ A U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 B C D Install Video SPECIFICATIONS Input Voltage 24VDC 10 Wire gauge Minimum 18 gauge Direct wire run no relays or access control units in between ...

Страница 2: ...ALLATION EXAMPLE Recommended Power Supplies All Command Access exit devices field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory For more information click here or go to our website U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 ...

Страница 3: ...rop plunger bracket over the front activitaing arm 4 Make sure the plunger bracket slides all the way to the back where the screw is past the tab 5 6 Once plunger bracket is past tab tighten screw all the way to prevent the bracket from moving forward U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 ...

Страница 4: ... t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 10 Move solenoid mount up towards plunger install remaining 2 screws to mount DO NOT TIGHTEN 11 To find correct solenoid position pull back on the plunger bracket confirm starwheel is free to rotate Once starwheel moves freely this is the correct position Rel...

Страница 5: ...it works properly Add wire tie strain relief pad to secure power cable U S c u s t o m e r s u p p o r t 1 8 8 8 6 2 2 2 3 7 7 w w w c o m m a n d a c c e s s c o m C A c u s t o m e r s u p p o r t 1 8 5 5 8 2 3 3 0 0 2 15 Add power connector to power wires push them into the connector make sure the tabs on the wire pins are facing up The tabs will lock pins into the connector TOP TAB ...