background image

                                                                          

 

 COMM-TEC Germany                                       www.comm-tec.de

 

 

COMM-TEC UP-1200 Switching Scaler Manual 
 

 

用户手册

 

 

b. 

Audio channel switching 

By  default  the  digital  inputs  use  their  embedded 
audio.  The  analog  video  inputs  are  mapped  to 
the  analog  inputs  as  shown  on  the  front  panel 
(e.g.  CV

 Audio  1,  VGA1 

 Audio  3).  But  you 

can map any of the 9 analog audio inputs to any 
video input by using the audio mapping function 
of the UP-1200 as follows:  
 

Step  one

:  Press  the  AV  button  to  choose  an 

analog  audio  input  to  be  mapped  to  the  current 
video  input.  The  button  of  the  selected  audio 
input lights red.  

Step  two

:  Press  the  “AV”  button  again  to  store 

the  audio  mapping  and  to  leave  the  audio 
mapping menu.  
 

 

3,Setting the menu options 
Step one:

 Press any button to light up the LCD 

screen,  then  press  “MENU”  to  enter  the  menu 
option. 

Step  two:

  Turn  the  “PARAMETER”  knob  to 

select the desired setting, then press “ENTER”    

Step  three:

  Turn  the  “PARAMETER”  knob  to 

change  the  desired  parameter,  then  press 
“ENTER” to confirm the selection.  

Step  four: 

Press  the  “MENU”  to  return  to  the 

previous menu.  

If  the  current  operation  is  in  the  menu 

structure (as shown below), press “MENU” to 
return  to  the  previous  menu.  If  the  current 
state  is  audio  and  video  channel  switch, 
press “MENU” to display the main menu page 
of scaler.

 

 

2.4.4  Operation examples 

In  this  example  we  set  the  output  resolution  to 
1280X1024@60Hz,  the  brightness  to  60  and 
adjust the output volume to + 10.5dB. 
 

 

 
1.Press “MENU” to enter into the option menu  
The LCD will show: 

  

 

Press “ENTER” to select the option settings, and 
turn the PARAMETER knob to set the “OUTPUT 
Format”  parameter.  When  you  enter  the  menu, 
the  resolution  will  display  the  current  resolution, 
in this example 1920X1080@50Hz. 

 

 

 

3.  Rotate  the  “PARAMETER”  knob  to  select  the 
desired resolution 1280X1024@60Hz.  

 

 

  

4.  After  selecting  the  new  resolution,  press 
“ENTER”  to  confirm  the  changes.  The  LCD  will 
show the new resolution. 

 

Содержание UP-1200

Страница 1: ...Switching Scaler Version 1 1 Operating Instructions Thank you for purchasing our product Please be sure to read this instruction manual carefully before using our product UP 1200 Operating instructio...

Страница 2: ...insulation occurring within the equipment may cause people suffer from shock CE certification means that the product has reached the directive safety requirements defined by the European Union Users...

Страница 3: ...g Only after cutting down all external power source can install wiring operation begin or it may cause electric shock or equipment damage This product grounds by the grounding wires To avoid electric...

Страница 4: ...ion 3 2 2 RJ45 network cable producing methods 4 2 3 Diagram of system connection 5 2 4 Panel operating instructions 5 2 4 1 LCD display 5 2 4 2 Button lights 5 2 4 3 Operation introduction 5 2 4 4 Op...

Страница 5: ...ontrol Therefor the UP 1200 can be widely used in broadcast environments conference rooms education facilities command and control centers and other occasions 1 1 Features Supports 9 video signal inpu...

Страница 6: ...if you switch between the inputs audio follows video But you can manually select a different audio source audio breakaway for a video source By pressing the AV button you can manually select an audio...

Страница 7: ...VGA1 VGA2 video input interface and AUDIO INPUTS 1 4 audio interface have access to signals AUDIO INPUTS 1 and CV signal default fixed synthesis HDIM output AUDIO INPUTS 2 and YPbPr signal default fi...

Страница 8: ...ked with different colors There are two methods of twisted pair connection EIA TIA 568B standard and EIA TIA 568A standard T568A line order 1 2 3 4 5 6 7 8 White and green green White and orange blue...

Страница 9: ...l light up red You can setup the device by pressing the button MENU Menu operation steps can be summarized as Enter the menu choose option with parameter knob select option with ENTER button change pa...

Страница 10: ...desired setting then press ENTER Step three Turn the PARAMETER knob to change the desired parameter then press ENTER to confirm the selection Step four Press the MENU to return to the previous menu If...

Страница 11: ...just option 7 Press ENTER to enter the option parameter settings The LCD shows the current brightness value Use the PARAMETER knob to set the brightness value to 60 8 Press ENTER to confirm the change...

Страница 12: ...COMM TEC Germany www comm tec de 8 COMM TEC UP 1200 Switching Scaler Manual...

Страница 13: ...OMM TEC UP 1200 Switching Scaler Manual 2 5 Menu structure VGA Adjust is only valid when a VGA source has been connected to the UP 1200 COPY TO HDMI in EDID menu is only valid when a sink has been con...

Страница 14: ...g Scaler Manual Chapter Three Control Codes RS232 communication RS232 communications settings Baud rate 115200 configurable Data bits 8 Parity None Stop bits 1 Flow control None TCP IP communication T...

Страница 15: ...n S AUDIO 0 AUDIO 1 INPUT Select the AUDIO 1 INPUT S AUDIO 1 AUDIO 2 INPUT Select the AUDIO 2 INPUT S AUDIO 2 AUDIO 3 INPUT Select the AUDIO 3 INPUT S AUDIO 3 AUDIO 4 INPUT Select the AUDIO 4 INPUT S...

Страница 16: ...Response Description S OUTPUT 0 OUTPUT 640x480 60Hz Set output resolution to 640x480 60Hz S OUTPUT 1 OUTPUT 800x600 60Hz Set output resolution to 800x600 60Hz S OUTPUT 2 OUTPUT 1024x768 60Hz Set outp...

Страница 17: ...9 it means that the audio input are the embedded audio signals of the digital inputs HDMI1 HMDI2 HDMI3 and HDBaseT For example For adjust the second audio input to 12dB the corresponding command is A...

Страница 18: ...ut H Start 1 Move the VGA input image one column right HTotal VGA Input H Total 1 Add 1 column to the total of VGA input images HTotal VGA Input H Total 1 Remove 1 column of the total of VGA input ima...

Страница 19: ...AR 192 168 1 1 Set the gateway SUBR 255 255 255 0 SUBR 255 255 255 0 Set the subnet mask SPORT 6666 SPORT 6666 Set connection port number SIPR SIPR 192 168 1 190 Get the IP address GAR GAR 192 168 1 1...

Страница 20: ...2 25 Gbps lane Interface HDMI A interface Type A connector 3 HDMI input 1HDMI output Minimum maximum level T M D S 2 9V 3 3V Input EDID Use the system default EDID supports EDID mapping to the input R...

Страница 21: ...Noise 0 05 1 kHz with rated voltage Signal to Noise S N 80dB Stereo separation 80dB 1 kHz Signal type stereo Impedance input 10 k unbalanced maximum input level 19 5dBu Control types Front panel Illu...

Отзывы: