4.0
INSTALLATION
a)
Be sure that all units to be installed are in OFF state.
b)
Connect the source to INPUT RGBHV by a RG59 B/U cable.
ATTENTION
If your source gives signals RGB+S connect the S to the BNC H.
If your source gives the Sync On Green leave open the BNC H are V.
If your source has an HDD 15 p.f. as output connector,
use a COMM-TEC adapter cable as an interface.
c)
Connect the two destination with BNC RGBHV output by a RG59 B/U cable.
d)
Power the unit as described in chapter 2.0 and check that the led POWER on
front panel lights up.
ATTENTION
DA-12R does not process the sync.
So the destinations must be compatible with the source.
If they aren't it's necessary to interpose an interface
type COMM-TEC IF-11V or IF-12VA
ATTENTION
The length of cables which bring RGB signals must be
the same with a tolerance of 0,5 m. Greater difference may
cause a significative loss of the image resolution.