SPECIFICATIONS

Model

SWR TRUE Type 3013

Application

Measurement of SWR in 50 

Ω

 transmission 

lines

Frequency range

30->2700 MHz entered as centre and span

Center Frequency

30 to 2700 MHz.

Span

0 to 2670 MHz.

Frequency stability

±20ppm

Measurement range

1.0<SWR<9.9, 0<dB<-30dB

Impedance

Nom. 50 

Ω

Generator output

Approx. -4dBm

Max. input on test terminal

100 mW

Tolerance on SWR reading

30-1000MHz)± 5%; 1000-1600MHz ± 10%; 

and 1600-2700MHz ±15%

Operating temperature range

0° C-> + 50° C

Storage temperature range

-30°C -> + 50° C

Connectors

“N”-female RF test connector.

USB A type for memory key.

USB B type for serial PC communication.

Mini DIN for RS232 communication up to 

38400 Baud

Power supply

4 NiMH type AA rechargeable batteries

(Batteries, NiMH rechargeable and 

110VAC/7.5VDC charger supplied)

Auto Power off

For battery economy, SWR TRUE automatically 

turns off 3 min. after last entry

Normal operating use

Fully charged: More than 10 hours.

Colour

Silver/blue

Width

82 mm

Depth

31 mm

Height

165 mm

Weight

500 gram (incl. Batteries)

EMC

Complies with directive 89/336EEC as 

amended by 92/31EEC and 93/68/EEC

Standards

Emissions: EN 61000-6-4: 2001

Immunity: EN 61000-6-2: 2005

XML FEATURE:

In order to use the XML feature this must be installed. 

When the feature is installed You can take advantage of 

the info menu 5 where operator , address, device and 

types can be entered.

Also you can choose between the stan- dard .bmp picture 

copy (File sys 1)or the XML type where all info is copied 

onto the USB memory stick (File sys 2)

Along with the XML Feature is a USB Memory Stick with 

program files:

After inserting the USB 

memory stick into the SWR 

True and pressing “COPY” 

the Screen is copied to the USB memory stick along with Info data, time of day, date 

and table data for each of the 101 data points on screen.

Taking the USB memory stick to your PC you can execute the “merge.bat” program 

which will give you all stored data in the following format:

Содержание SWR TRUE

Страница 1: ...SWR TRUE Antenna Analyzer EDITION NOTICE This publication applies to COMM connect A S SWR True type 3013 SWR Analyzer product hardware release 1A and software release 3013 suffix 3B 2008 Operators Man...

Страница 2: ...by a microprocessor The microprocessor is running in a MOP Micro Operating Program environment The MOP schedule and execute all tasks required to handle the LCD Screen the Key board The RF generator...

Страница 3: ...ly from the charger and at the same time charge the bat teries when plugged in Also the cigarette lighter supplied in the accessory kit can run and charge the instrument from your 12Volt car battery a...

Страница 4: ...are controlled by the arrow keys when the instrument is in sweep mode By pressing the left or right arrow the marker line moves across the screen When the key is held pressed a mini cursor will be see...

Страница 5: ...Feature is installed Settings 4 is the choice of having the RF generator stopped or running dur ing HOLD mode 4 Date and Time The date and time can be entered and will run real time as long as the SWR...

Страница 6: ...cifications Range 890 960 MHz SWR less than 2 0 1 typical 1 5 1 Nearby objects When testing SWR on low gain antennas Gain 3dBd the influence from nearby objects is small when the objects are more than...

Страница 7: ...st entry Normal operating use Fully charged More than 10 hours Colour Silver blue Width 82 mm Depth 31 mm Height 165 mm Weight 500 gram incl Batteries EMC Complies with directive 89 336EEC as amended...

Страница 8: ...or each point on the screen sepa rated by commas Each data entry is the frequency reflection coeffi cient RHO Return loss in dB and the VSWR The spread sheet files can be viewed with the program CSVIE...

Страница 9: ...0 100 1 22 25 0 056 1 12 30 0 032 1 07 35 0 018 1 04 40 0 010 1 02 SWR VSWR Voltage Standing Wave Ratio RF Radio Frequency MHz Mega Hertz GaAs Gallium Arsenide MMIC Monolithic Microwave Integrated Cir...