![COMM-connect SWR TRUE Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/comm-connect/swr-true/swr-true_operators-manual_2642159007.webp)
13
14
SPECIFICATIONS
Model
SWR TRUE Type 3013
Application
Measurement of SWR in 50
Ω
transmission
lines
Frequency range
30->2700 MHz entered as centre and span
Center Frequency
30 to 2700 MHz.
Span
0 to 2670 MHz.
Frequency stability
±20ppm
Measurement range
1.0<SWR<9.9, 0<dB<-30dB
Impedance
Nom. 50
Ω
Generator output
Approx. -4dBm
Max. input on test terminal
100 mW
Tolerance on SWR reading
30-1000MHz)± 5%; 1000-1600MHz ± 10%;
and 1600-2700MHz ±15%
Operating temperature range
0° C-> + 50° C
Storage temperature range
-30°C -> + 50° C
Connectors
“N”-female RF test connector.
USB A type for memory key.
USB B type for serial PC communication.
Mini DIN for RS232 communication up to
38400 Baud
Power supply
4 NiMH type AA rechargeable batteries
(Batteries, NiMH rechargeable and
110VAC/7.5VDC charger supplied)
Auto Power off
For battery economy, SWR TRUE automatically
turns off 3 min. after last entry
Normal operating use
Fully charged: More than 10 hours.
Colour
Silver/blue
Width
82 mm
Depth
31 mm
Height
165 mm
Weight
500 gram (incl. Batteries)
EMC
Complies with directive 89/336EEC as
amended by 92/31EEC and 93/68/EEC
Standards
Emissions: EN 61000-6-4: 2001
Immunity: EN 61000-6-2: 2005
XML FEATURE:
In order to use the XML feature this must be installed.
When the feature is installed You can take advantage of
the info menu 5 where operator , address, device and
types can be entered.
Also you can choose between the stan- dard .bmp picture
copy (File sys 1)or the XML type where all info is copied
onto the USB memory stick (File sys 2)
Along with the XML Feature is a USB Memory Stick with
program files:
After inserting the USB
memory stick into the SWR
True and pressing “COPY”
the Screen is copied to the USB memory stick along with Info data, time of day, date
and table data for each of the 101 data points on screen.
Taking the USB memory stick to your PC you can execute the “merge.bat” program
which will give you all stored data in the following format: