14
The picture below illustrates the minimum required distances from each side of the heat pump.
3.2 Distance to the pool
Install the heat pump as close to the swimming pool as possible to minimize heat loss through the piping.
3.3 Connecting the bypass
With the bypass set correctly, your heat pump will deliver its best performance. The bypass has to be built
as shown below:
VALVE1
–
Slightly closed
(water pressure increased from 10 to 20 bar)
VALVE2
–
Completely open
VALVE3
–
Half way open
Setting the valve of the bypass:
1. Open all 3 valves entirely
2. Slightly close valve 1
3. Close valve 3 about half way to adjust the
refrigerant pressure
Содержание ECO+10
Страница 20: ...20 6 Detailed specifications 6 1 Electrical wiring diagram of the heat pump ...
Страница 37: ...37 6 Gedetailleerde specificaties 6 1 Elektrisch bedradingsdiagram van de warmtepomp ...
Страница 54: ...54 6 Detaillierte Spezifikationen 6 1 Elektrisches Anschlussschema der Wärmepumpe ...