FURNACE SPECIFICATIONS
4
¹ Natural Gas BTU/h
²
³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
⁴
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
⁵
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
•
•
and noise issues.
•
may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
*MVM97
0603BNA
*MVM97
0803BNA
*MVM97
0804CNA
*MVM97
1005CNA
*MVM97
1205DNA
Heating Data
Hi gh Fi re Input¹
60,000
80,000
80,000
100,000
120,000
Hi gh Fi re Output¹
58,200
77,600
77,600
97,000
116,400
Low-Fi re Stea dy-Sta te Input¹
30,000
40,000
40,000
50,000
60,000
Low-Fi re Stea dy-Sta te Output¹
29,100
38,800
38,800
48,500
58,200
AFUE²
97
97
97
97
97
Tempera ture Ri s e Ra nge (°F)
20 - 50
30 - 60
25 - 55
35 - 65
35 - 65
Vent Di a meter³
2" - 3"
2" - 3"
2" - 3"
2" - 3"
2" - 3"
No. of Burners
3
4
4
5
6
Circulator Blower
Ava i l a bl e AC @ 0.5” ESP
1.5 - 3
1.5 - 3
1.5 - 4
41,675
41,675
Si ze (D x W)
11" x 8"
11" x 8"
11" x10"
11" x 10"
11" x 11"
Hors epower @ 1075 RPM
1/2
1/2
3/4
1
1
Speed
VS ECM
VS ECM
VS ECM
VS ECM
VS ECM
Filter Size (in²)
Perma nent
739
766
862
862
1035
Di s pos a bl e
370
383
431
431
517
Electrical Data
Mi n. Ci rcui t Ampa ci ty
4
8.8
8.8
11.6
15.4
15.4
Max. Overcurrent Devi ce (a mps )
5
15
15
15
20
20
Shipping Weight (lbs)
118
121
142
144
157