background image

PREPARATION

1.  Check the mains power supply matches the specifications 

(220V)

2.  Check if switches, tubes and accessories are properly 

connected and if the unit works normally.

3.   Refill the serum bottles if necessary

4.  Check the condition and contents of suction bottles and 

tubes before use.  Contents of the suction bottle should 
be cleaned out after every use. Wash with warm water 
and mild detergent, rinse clean before re-attaching to 
system.

5.  Connect the suction bottle as shown. Make sure the 

bottle is properly installed on the unit and suction bottle 
cover is sealed correctly. Make sure the bottle has 
sufficient space to collect waste.

6.  Ensure the stainless steel springs are firmly connected to 

the two large tubes.

Note:

Ensure only authorized, qualified persons operate the unit.  

Read owners manual thoroughly before first use.

1. 

Remove clear treatment tip from hand piece and fit the blue cleaning tip in its place.

2. 

Remove Solution 1 bottle and replace with white cleaning bottle filled with a 10:1 distilled water and white vinegar 
solution. Place suction tube and cap onto white cleaning bottle

3. 

Turn the flow dial to maximum.

4. 

Press the Solution 1 on/off button and run cleaning tip for 2 minutes.

5. 

after 2 minutes, repeat the same procedure with the solution 3 side of the system.

6. 

Turn off machine, empty cleaning bottle and rinse thoroughly.

7. 

Repeat steps 2 - 6 with distilled water only (no vinegar) in the cleaning bottles to flush the system of cleaning fluid.

1. 

Install power cord into base and plug into power source and turn on main power switch

2. 

Press the on/off button for Solution 1  (green) or Solution 3 (orange) to start

3. 

Set vacuum setting to 3, and flow rate setting just above minimum to begin, then adjust according to client skin 
type and comfort, and treatment objective. 

4. 

Put hand piece on skin and apply treatment

5. 

After finishing each session, ensure equipment is cleaned as per recommended procedure

OPERATION