background image

Jan 2022 Ver 200/ 201

365

Comfort

D y n a m i c  A i r f l o w  C o n t r o l

CAUTIONS

Use cautions when mounting components to surfaces 
that may have concealed wiring beneath the surface.

Turn off power to HVAC equipment before installing or 
servicing airflow controls.

Read and follow all instructions carefully.

Follow all local electrical codes during installation. All 
wiring must conform to local and national electrical 
codes.

Read entire manual before installing products.

Installation should be performed by a qualified 
individual with sufficient experience and skill.

!

The WDDCK Kit includes:

Wired Direct Damper Control

Installation Manual

Model WDDCK

Patent US 10,520,212 B1

WDDC Wired Damper Control.

DDC1 Damper Control Module. 

Connect the DDC1 Damper Control to R and C terminals at the 
equipment using 2 conductor, 18 or 20 ga. thermostat cable. 
Connect the DDC1 Damper to the WDDC Wall Control using 3 
conductor, 18 or 20 ga. thermostat cable.

Step 3. Wire the DDC1 Damper Control

The DDC1 Damper Control is 
installed near the HVAC equipment 
on a non-metal surface using the 
hardware kit.

Step 1. Install the DDC1 Damper Control

To remove the cover, press the 
plastic tabs in the area indicated. 

Not intended as a zoning system. See eControlsUSA.com for
zoning solutions.

Compatible with R80CJ-XX Dampers (unsealed) or 
R80JZD-XX Dampers (sealed).

Damper sold separately.

WDDC Wired Damper Control Wiring Diagram

2

R80CJ or R80JZD Damper.

 Installed in the duct 

controlling airflow to the space.

Plug&Play Cable Included

IN

OUT

IN

To 24VAC (R and C)
at the equipment or
24VAC, 40VA transformer.

Wired Damper Control
24VAC, 4VA

eControls, Inc.
Laguna Hills, CA 
eControlsUSA.com

Patent US 10,520,212 B1

Model DDC1

Made 
in the 

USA

WDDC Wired Damper Control

DDC1 Damper Control Module

Installed near equipment

3

Wired Damper Control
24VAC, 4VA

eControls, Inc.
Laguna Hills, CA 
eControlsUSA.com

Patent US 10,520,212 B1

Model DDC1

Made 
in the 

USA

Wired Damper Control
24VAC, 4VA

eControls, Inc.
Laguna Hills, CA 
eControlsUSA.com

Patent US 10,520,212 B1

Model DDC1

Made 
in the 

USA

DDC1

Damper Control

GND

TS

VP

R
C

TS

V+

HVAC 

System

R
C

WDDC 

Wall Control

GND

VP

V+

The WDDC can be installed directly to any wall, about 5’ off the 
floor. See cut out template on page 2.

Step 2. Install the WDDC Wall Control