5
Model No. CZPP21
G
ENERAL
INFORMA
TION
AND
M
AINTENANCE
T
ECHNICAL
S
PECIFICA
TIONS
• When operating the unit at altitudes over 7000 feet
(2134 meters) above sea level the unit may not burn
as bright as lower altitudes. This is normal. At higher
altitudes, the heater may shut off. If this happens, make
sure there is fresh air, wait 5 minutes and re-light. Due to
local atmospheric conditions heater may not re-light.
• Operating time will vary based upon the conditions
including temperature, heater settings and cylinder
size.16.4 oz./465 g. (1.02 lb.) cylinder should last
3 - 4 hours on high setting. (depending on conditions
such as amount of gas in the cylinder and temperature
of tank and surrounding areas).
•
When using the unit as a stove, be sure the cooking
utensil being used is stable on the cook top surface
and will not to fall or tip over and injure surrounding
individuals.
• Keep area clear and free from combustible materials and
other flammable vapors and liquids.
• Do not obstruct the flow of combustion and ventilation of air.
• When operating properly, the flame should be blue
coming out of the burner orifices and flame tip should be
about 1/4" (6.4 mm) with some yellow flames rising out of
the flame tips. Yellow flames mixed in is OK as long as
no carbon or soot appears. It is normal that the mesh will
glow shades of orange during operation and the cook-
top burner vents may get red.
• Clean unit when it appears dirty or when performance
seems to diminish.
• To clean, make sure heater/stove is cool.
Disconnect propane tank from regulator. Remove gas
hose from heater/stove using two wrenches as described
in “Lighting and Operating Instructions".
Wipe unit clean with a soft cloth and dish detergent.
Do not use abrasive cleaners on the unit. Allow unit to dry
completely before use.
Output:
6500 max BTU’s
Category:
Pressure regulated propane
Fuel:
16.4oz 16.4 oz (465 g) or 1.02 lb disposable propane
cylinder with #600 connection.
Regulator:
Model # JY50-001, 11" W.C., 2.8 kPa
Hose and Connections:
24" (61cm.) length, 5/16"
diameter gas hose with 3/8" female flare connection on one
end and 1/4" male IP connection on the other.
Run Time:
Cylinder should last 3 - 4 hours on high setting
(depending on conditions such as amount of gas in the
cylinder and temperature of tank and surrounding areas).
Minimum Clearance from Combustible Materials:
Top
36 in. (92 cm)
Sides
24 in. (61 cm)
Содержание CZPP21