![Comfort Zone CZ225ER Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/comfort-zone/cz225er-series/cz225er-series_manual_2641517006.webp)
6
6
www.comfortzoneproducts.com
and secure with the small knob-screws and tighten all.
See
Figure 5.
CONNECTING THE POWER:
1. With the power off at the breaker, remove all screws from the
bottom lid for access to the electrical section of the heater.
2. Attach flexible cable through a knock-out in the side of the
heater following NEC and local codes, See
Figure 6
and
SPECIFICATIONS
for recommended wiring and
circuit breakers.
NOTE:
For certain applications, conduit may be required
3ft.
min.
1
2
7
3
4
12
If Heater is to
be turned
and wire is
inside conduit.
If Heater is to
be connected
with NM Cable.
If Heater is to
be connected
with Flexible
Conduit.
FLEXIBLE
CONDUIT
FLEXIBLE
NM CABLE
FLEXIBLE NM CABLE
CONNECTOR
(use per electircal codes)
FLEXIBLE CONDUIT
CONNECTOR
(use per electircal codes)
FLEXIBLE
CONDUIT
CONNECTOR
CONDUIT
CONDUIT
CONNECTOR
Figure 6
(See
Figure 6
). Check local electrical codes. If you run the
wiring in conduit and wish to be able to turn the heater be sure
to purchase enough flexible conduit to allow the heater to be
turned.
3. Pull enough wire into the heater and connect the wire to the
Power Block located in the electrical area of the heater,
See
Figure 7.
4. Be sure to torque all terminal screws and power block lugs
tight, see
SPECIFICATION
and NEC/local codes, for
L1
L2
GROUND
(or bare copper)
HOT
HOT
Figure 7
required
torque values
, failure to do so can overheat the
power blocks.
5. Turn on power at the main circuit breaker panel. Notice the
YELLOW Power Indicator Light on the Control Panel will glow.
WARNING:
It is advised that at the start of each heater season,
the power should be turned off at the circuit breaker and the
LI & L2 lug screws checked for tightness and
proper torque
.
The heater should be cleaned and checked for mechanical and
electrical integrity. See
SPECIFICATION
and NEC/local codes.
ADJUSTING AIR FLOW:
1.
Swivel the unit
- If mounted on a single center lag bolt
Figure
4a,
turn the entire heater and bracket assembly left or right.
2.
Tilt the unit
- Loosen the top Small Knob-Screws and thread
into provided holes in heater until tight. See
Figure 5
.
3.
Adjust the louvers
in front of the heater as desired. See
Figure 5
.
NOTE:
DO NO OPERATE THE HEATER WITH THE FRONT
LOUVERS CLOSED, DAMAGE TO THE HEATER COULD
RESULT.
SAFETY INSTRUCTIONS:
To start the heater, turn on the circuit breaker. The Power Indicator
light will light up to indicate there is power available. Press the
POWER button to turn the heater on. The heater will be in HIGH
setting by default. The heater indicator will illuminate, and the
LED display will show the default setting temperature 80°F.
1. The heater is HOT when in use. Do not let bare skin touch any
hot surfaces.
2. Keep combustible materials (furniture, pillows, bedding,
papers, clothes, curtains, and similar items) at least 3
feet (0.9m) from all sides and surfaces of the heater.
3. Do not use outdoors or in wet areas like bathrooms, laundry
areas or where it could fall into a swimming pool or other
container of water.
4. This heater is a 240V AC rated direct wired appliance. Never
use extension cords or relocatable power taps.