Comfort Zone CZ225ER Series Скачать руководство пользователя страница 1

Save These Instructions

www.comfortzoneproducts.com

Models: CZ225ER Series 

CZ230ER Series

Digital  

Ceiling Mounted Heater

HARDWIRED INSTALLATION REQUIRED 

This heater must be grounded and hardwired to a properly 

sized current protection circuit breaker in accordance with 

the (US) National Electric Code and local codes. 

*Model pictured is CZ225ER. 
  Model purchased may look  
  slightly different.
Models 
CZ225ER2C 
CZ230ER2C  
have 2  
remote controls

Description

• Adjustable Heat Settings with Digital Thermostat
• Fan-Forced for Wide Heat Circulation
• Fan Only Setting for Year-Round Air Circulation
• 12-Hour Timer with Auto Shut-Off
• Horizontal and Vertical Air Flow with Tilt Feature
• Sturdy Heavy Gauge Steel Body
• Remote Control
• High Limit Thermal Cut-Out Switch

Содержание CZ225ER Series

Страница 1: ...US National Electric Code and local codes Model pictured is CZ225ER Model purchased may look slightly different Models CZ225ER2C CZ230ER2C have 2 remote controls Description Adjustable Heat Settings...

Страница 2: ...er is left operating and unattended 11 Use this heater only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons WARNING Imp...

Страница 3: ...T WEIGHT APPROXIMATE BETWEEN 25 TO 30 LBS SPECIFICATIONS CZ225ER SERIES DIGITAL HEAVY DUTY 6 000W ELECTRIC UTILITY HEATER WATTS SWITCH POSITION VOLTS VAC PHASE AMPS BTU HOUR 6 000W HIGH Default 208 24...

Страница 4: ...t 10 seconds after initial start to push the heat out The sequence is HIGH LOW FAN ONLY To operate the unit on FAN ONLY setting press the MODE button again In FAN ONLY mode the LED display panel will...

Страница 5: ...discharge of each heater supports the air flow of the others to provide best circulation of warm air as indicated below in Figure 3 BRACKET INSTALLATION FOR CZ225ER AND CZ230ER SERIES Refer to Figure...

Страница 6: ...breaker panel Notice the YELLOW Power Indicator Light on the Control Panel will glow WARNING It is advised that at the start of each heater season the power should be turned off at the circuit breaker...

Страница 7: ...urchased outside the continental United States return the unit to the place of purchase This warranty does not cover damage caused by misuse abuse overheating or alteration Repairs made by anyone othe...

Страница 8: ...n overheat condition E2 Room Temp Sensor Open Circuit Detached or Loose Connection at Room Temperature Sensor Disconnect power Detach Fan Grille by removing screws Locate Temp Sensor Thermocouple on H...