Comfort Glow (VENT-FREE) GAS STOVE HEATER Скачать руководство пользователя страница 2

www.desatech.com

115580-01A

2

WARNING:  Improper  installation,  adjustment,  altera-
tion, service or maintenance can cause injury or prop-
erty damage. Refer to this manual for correct installation 
and  operational  procedures.  For  assistance  or  addi-
tional information consult a qualified installer, service 
agency or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses 
air (oxygen) from the room in which it is installed. Provi-
sions for adequate combustion and ventilation air must 
be provided. Refer to 

Air for Combustion and Ventilation

 

section on page 5 of this manual.

This appliance may be installed in an aftermarket,* per-
manently located, manufactured (mobile) home, where 
not prohibited by local codes.
This appliance is only for use with the type of gas indi-
cated on the rating plate. This appliance is not convert-
ible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

State of Massachusetts:

 The installation must be made by a licensed plumber or gas fitter in the 

Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each 

purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the Common-

wealth of Massachusetts.

TABLE OF CONTENTS

Safety Information ............................................... 3
Product Identification ........................................... 4
Local Codes ........................................................ 4
Product Features ................................................. 5
Air For Combustion and Ventilation ..................... 5
Installation ........................................................... 7
Operating Heater ............................................... 15
Inspecting Burners ............................................ 16
Cleaning and Maintenance ................................ 17

Troubleshooting ................................................. 18
Specifications .................................................... 21
Service Hints ..................................................... 21
Technical Service .............................................. 21
Replacement Parts ............................................ 21
Accessories ....................................................... 21
Illustrated Parts Breakdown and Parts List ....... 22
Parts Centrals .................................................... 26
Warranty Information ............................Back Page

Содержание (VENT-FREE) GAS STOVE HEATER

Страница 1: ...electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the re de...

Страница 2: ...the rating plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation mus...

Страница 3: ...ols can be dangerous WARNING Donotallowfans to blow directly into the stove Avoidanydraftsthatalterburner ame patterns Ceiling fans can create drafts that alter burner ame patterns Altered burner patt...

Страница 4: ...ion page 5 If heater keeps shutting off see Troubleshooting page 18 12 Do not run heater where ammable liquids or vapors are used or stored under dusty conditions 13 Do not use this stove to cook food...

Страница 5: ...oper combustion and ventilation Exhaust fans replaces clothes dryers and fuel burning appliances draw air from the house to operate You must provide adequate fresh air for these appliances This will i...

Страница 6: ...lume of space x 20 maximum Btu Hr the space can support Example 2560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support AIR FOR COMBUSTION AND VENTILATION Continued 3 Add the Btu H...

Страница 7: ...your pri mary heat source If you have a centralheatingsystem youmay run system s circulating blower whileusingheater Thiswillhelp circulatetheheatthroughoutthe house In the event of a power outage yo...

Страница 8: ...G This appliance is equipped for natural or pro pane LP gas Field conversion is not permitted INSTALLATION Continued CLEARANCES TO COMBUSTIBLES Vent Free Operation Only WARNING Maintain the minimum cl...

Страница 9: ...avoidscratching stove edges INSTALLATION Continued Figure 5 Removing Back Panel Bolt Product Identi cation Label Back Stove Panel Figure 6 Laying Down Stove On Side Stove Style May Vary Depending on M...

Страница 10: ...olt stop and the bottom nut is for door leveling adjustment 12 Check general catch bolt alignment with door claw Make nal adjustment and door leveling after stove is in normal standing position 13 Car...

Страница 11: ...through stove bottom Connect hex nut to bolt on underside of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sockets are not available use adjustable wrenc...

Страница 12: ...uge connection Purchase the optional CSA design certi ed equipment shutoff valve from your dealer See Accessories page 21 Figure 17 Gas Regulator Location and Gas Line Access Into Stove Cabinet Back S...

Страница 13: ...lator Natural From Gas Meter 5 W C to 10 5 W C Pressure CSA Design Certi ed Equipment Shutoff Valve With 1 8 NPT Tap Approved Flexible Gas Hose if allowed by local codes We recommend that you install...

Страница 14: ...igure 20 2 Pressurize supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed...

Страница 15: ...ou do not fol low these instructions exactly a re or explosion may result causing property damage per sonal injury or loss of life A This appliance has a pilot which must be lighted by hand When light...

Страница 16: ...odulating down in most cases MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 5 under Lighting Instructions page 15 2 Depress control knob and light pilot with match 3 Keep control knob pressed in f...

Страница 17: ...se follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly Note Removing the rear panel and top grates of your stove will make cleaning easier 1...

Страница 18: ...ssure B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at control valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pi...

Страница 19: ...knobtoLOposition and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installation clearances...

Страница 20: ...t is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page OBSER...

Страница 21: ...you to return the part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Central see...

Страница 22: ...www desatech com 115580 01A 22 ILLUSTRATED PARTS BREAKDOWN SL30PT Shown SL30NT 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13...

Страница 23: ...er Tube 1 8 099056 19 099056 26 Burner Ori ce Injector 1 9 111124 01 111124 01 Burner Retainer Spring 1 10 102980 01 102980 01 Burner 1 11 101329 22 101329 21 Control Valve 1 12 104472 01 104472 01 Br...

Страница 24: ...www desatech com 115580 01A 24 ILLUSTRATED PARTS BREAKDOWN CISC CISG 7 4 6 4 5 4 5 1 5 2 3 5 3 5 4 2 1R 1C 1L...

Страница 25: ...70 01 One Leg Charcoal 4 Total Per Stove 1 104970 02 One Leg Forest Green 4 Total Per Stove 1 5 104971 01 Hardware Kit 1 5 1 Door Hinge Step Bolt With Shoulder 1 Per Unit 1 5 2 Door Catch Bolt M8 x 1...

Страница 26: ...ng Green KY 42103 3414 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www...

Страница 27: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 28: ...ed by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXT...