Installation Items Needed (Not Provided)

Fig. 15 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

Flexible Gas Line or 

Black Pipe to Heater 

Cabinet Regulator

To Regulator

• 8'' Adjustable Wrench
• 8'' Pipe Wrench
• 1/2'' Flexible Gas Line (24'' Min.) or 1/2'' Black Pipe
• 90 Deg. 1/2 NPT x 3/8'' Flare Fitting or 3/8'' NPT x 1/2 NPT Street Elbow
• Sealant (Resistant to Propane (LP) Gas)

• Shut Off Valve

• Allen Wrench

1) A variety of options are possible for routing the Gas Connection Lines depending on where 
   your Gas Supply line is located. 

2) Identify the gas inlet on the Heater that corresponds to the fuel type for your installation. Re-
move the threaded plug by turning counterclockwise. 

Install a 90 degree fitting - not included). Be sure to use a gas resistant sealant on the 3/8 NPT 

fitting. Position the fitting so the inlet line can be attached without binding.
3) Install the Gas Line to the 90 Deg. fitting and attach to the Shut Off Valve. 

4) Check all connections for gas leaks.
5) Install receiver and plastic Heat shield by attaching the (2) wires from the receiver to the (2) 
wires from the Gas Control Valve insuring you match the wire colors. Place the receiver on the 

fireplace floor adjacent and slightly behind the Gas Valve control knob with the sensor eye fac

-

ing toward the room.

NOTICE:

 Most building codes do not permit concealed gas connections. Check 

your local building code prior to using a Flexible Gas Line for this installation.

 CAUTION

: Use pipe joint sealant that is resistant to gas (PROPANE or NG). We

 

recommend that you install a sediment trap in a supply line. Locate sediment trap where it is within 

     reach for cleaning and not likely to freeze. Install in the piping system between fuel supply and 
     heater. A sediment trap traps moisture and contaminants. This keeps them from going into heater 
     controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly.

 

CAUTION

: Avoid damage to regulator. Hold gas regulator with wrench when

  connecting into gas piping and/or fittings. NG Models: 6 in. to 14 in. W.C. Gas

 

supplier provides external regulator for natural gas.

Propane (LP)

Gas Inlet 

Natural Gas (NG)

Inlet Location

Содержание GLD2466R

Страница 1: ...is manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas...

Страница 2: ......

Страница 3: ...ural or propane LP gas supplier Specifications 2 Important Safety Information 3 Product Identification 5 Product Features 6 Preparing for Installation 7 Installation 10 Unpacking 15 Log Assembly 21 Op...

Страница 4: ...his manual for reference It is your guide to operating this heater safely WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies Heater becomes ver...

Страница 5: ...ater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation page 9 If heater keeps shutting...

Страница 6: ...5 PRODUCT IDENTIFICATION Burner Tube Ember Bed Receiver Remote Transmitter LP ODS Pilot NG ODS Pilot Battery Ignitor Control Valve Grate Grate Cap Log Locator Pin Push Button Ignitor...

Страница 7: ...ssachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented...

Страница 8: ...ft per 1 000 BTU hr 4 8 m 3 per kw of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cu ft per 1 000 BTU hr...

Страница 9: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Страница 10: ...Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or duct Yo...

Страница 11: ...alling heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 8 through 10 CHECK GAS TYPE Be sure your gas supply i...

Страница 12: ...ollow diagram in Figure 2 5 B Clearances from the top of the heater opening to the ceiling should not be less than 36 WARNING Maintain the minimum clearances If possible provide greater clearances fro...

Страница 13: ...4 Fig 3 Minimum Clearance for Combustible to Wall Fig 4 Heat resistant material slate marble tile etc above fireplace If Using Mantel You must have noncombustible material s such as slate marble tile...

Страница 14: ...and top of fireplace opening your installation see Fig 5 NOTICE Surface temperature of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may become too hot to...

Страница 15: ...e fireplace you must install appliance at least 5 in above the combustible flooring see Fig 8 Hearth Combustible Material Combustible Material 5 in Min 14 in Min NonCombustible Material Hearth Combust...

Страница 16: ...r if required Piping check local codes Equipment shutoff valve Test gauge connection Sediment trap Tee joint Pipe wrench Allen wrench 3 8 NPT to 1 2 flare fitting UNPACKING 1 Remove logs grate and bur...

Страница 17: ...Proceed to installing the gas line as instructed in the Owner s Manual Convert to natural gas Step 1 Remove access panel WARNING This appliance can be used with propane or natural gas It is shipped f...

Страница 18: ...ccur Install external regulator with the vent pointing down as shown in Fig 13 Pointing the vent down protects it from freezing rain or sleet Purchase the optional equipment shutoff valve from your lo...

Страница 19: ...Install receiver and plastic Heat shield by attaching the 2 wires from the receiver to the 2 wires from the Gas Control Valve insuring you match the wire colors Place the receiver on the fireplace flo...

Страница 20: ...rrect all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment sh...

Страница 21: ...ly into firebox with the front pan facing forward Drill two 2 5 32 diameter holes approximately 1 deep Anchor the front pan to the floor using the 2 Concrete Attachment Screws Not Included See Fig 11...

Страница 22: ...og is marked with a number and this number will help you identify each log during installation Provided Logs 8 Fig 19 Installing Log 1 Fig 20 Installing Log 2 3 Fig 21 Installing Log 4 1 Insert log 1...

Страница 23: ...the unit and directions for the size and placement must be followed explicitly 1 Open the small bag and remove all of the ember material 2 Tear the material into rectangular shapes approximately 1 2...

Страница 24: ...ob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in fire or explosion D Do not use this appliance if any part has be...

Страница 25: ...rol knob 6 With control knob depressed push down on the ignitor button until the pilot lights The pilot s location is behind log 3 near the center of the burner See Fig 27 7 Keep control knob depresse...

Страница 26: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 27: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 28: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 29: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 30: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 31: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 32: ...cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 30 turn heater off see To Turn Off Gas to Appliance page 24 see Troubleshooting page 34 WARNING Do not allow fan...

Страница 33: ...a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30...

Страница 34: ...of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the orifice holder 6 In case any large clumps of dust have now been pushed into the bu...

Страница 35: ...trode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad push button ignitor 7 Bad Battery 1 Replace electrode 2 Replace electrode 3 Replace ignitor cabl...

Страница 36: ...an burner see Care and Maintenance page 25 26 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Cl...

Страница 37: ...ective Moisture conden sation noticed on windows 1 Not enough combustion ventilation air Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit 1 Residues f...

Страница 38: ...g 3 1 H 010B H 003B 1 4 Log 4 1 H 0075 H 0075 1 5 Log 5 1 H 0139 H 0139 1 6 Log 6 1 H 0812 H 0812 1 7 Log 7 1 H 0370 H 0370 1 8 Log 8 1 H 0356 H 0356 2 Grate 1 GP289 01 GP290 01 3 Grate End Cap 1 GP28...

Страница 39: ...Y IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED...

Страница 40: ...Y IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED...

Отзывы: