background image

10

INSTALLATION

  

NOTICE: 

This heater is intended for use as supplemental heat. Use this heater along with your 

   

primary heating system. Do not install this heater as your primary heat source. If you have a 

   

central heating system, you may run system’s circulating blower while using heater. This will 

   

help circulate the heat throughout the house. 

  

WARNING:

 A qualified technician must install heater. Follow all local codes.

  

WARNING:

 Never install the heater:

   

• in a bedroom or bathroom

   

• in a recreational vehicle

   

• where curtains, furniture, clothing, or other flammable objects are less than 42

   

in. from the front, top or sides of the heater.

   

• in high traffic areas

   

• in windy or drafty areas

CAUTION: 

This heater creates warm air currents. These currents move heat to wall surfaces next 

to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities 

(such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air 

exist, may cause walls to discolor.

 

IMPORTANT: 

Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in 

rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for 

Combustion and Ventilation, pages 8 through 10.

CHECK GAS TYPE

Be sure your gas supply is right for your heater.  

  

WARNING: 

This appliance is designed for installation in only a solid-fuel burning masonry or 

   

UL 127 factory-built fireplace or in a listed ventless firebox enclosure. Exception: DO NOT 

   

install this appliance in a factory-built fireplace that includes instructions stating it has not been  

   

tested or should not be used with unvented gas logs. 

  

WARNING: 

Solid-fuels shall not be burned in a fireplace in which an unvented room heater is  

  

installed.

 

  

WARNING: 

Any outside air ducts and/or ash dumps in the fireplace shall be permanently  

   

closed at time of appliance installation.

WARNING:

 Any glass doors shall be fully opened when the appliance is in operation.

WARNING:

 Before installing in a solid-fuel burning fireplace, the chimney flue and firebox 

must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

WARNING:

 Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter 

burner flame patterns.

WARNING:

 Do not use a blower insert, heat exchanger insert or other accessory not ap-

proved for use with this heater.

Содержание GLD2466R

Страница 1: ...is manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas...

Страница 2: ......

Страница 3: ...ural or propane LP gas supplier Specifications 2 Important Safety Information 3 Product Identification 5 Product Features 6 Preparing for Installation 7 Installation 10 Unpacking 15 Log Assembly 21 Op...

Страница 4: ...his manual for reference It is your guide to operating this heater safely WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies Heater becomes ver...

Страница 5: ...ater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation page 9 If heater keeps shutting...

Страница 6: ...5 PRODUCT IDENTIFICATION Burner Tube Ember Bed Receiver Remote Transmitter LP ODS Pilot NG ODS Pilot Battery Ignitor Control Valve Grate Grate Cap Log Locator Pin Push Button Ignitor...

Страница 7: ...ssachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented...

Страница 8: ...ft per 1 000 BTU hr 4 8 m 3 per kw of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cu ft per 1 000 BTU hr...

Страница 9: ...TU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct...

Страница 10: ...Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or duct Yo...

Страница 11: ...alling heater in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 8 through 10 CHECK GAS TYPE Be sure your gas supply i...

Страница 12: ...ollow diagram in Figure 2 5 B Clearances from the top of the heater opening to the ceiling should not be less than 36 WARNING Maintain the minimum clearances If possible provide greater clearances fro...

Страница 13: ...4 Fig 3 Minimum Clearance for Combustible to Wall Fig 4 Heat resistant material slate marble tile etc above fireplace If Using Mantel You must have noncombustible material s such as slate marble tile...

Страница 14: ...and top of fireplace opening your installation see Fig 5 NOTICE Surface temperature of adjacent walls and mantels become hot during operation Walls and mantels above the firebox may become too hot to...

Страница 15: ...e fireplace you must install appliance at least 5 in above the combustible flooring see Fig 8 Hearth Combustible Material Combustible Material 5 in Min 14 in Min NonCombustible Material Hearth Combust...

Страница 16: ...r if required Piping check local codes Equipment shutoff valve Test gauge connection Sediment trap Tee joint Pipe wrench Allen wrench 3 8 NPT to 1 2 flare fitting UNPACKING 1 Remove logs grate and bur...

Страница 17: ...Proceed to installing the gas line as instructed in the Owner s Manual Convert to natural gas Step 1 Remove access panel WARNING This appliance can be used with propane or natural gas It is shipped f...

Страница 18: ...ccur Install external regulator with the vent pointing down as shown in Fig 13 Pointing the vent down protects it from freezing rain or sleet Purchase the optional equipment shutoff valve from your lo...

Страница 19: ...Install receiver and plastic Heat shield by attaching the 2 wires from the receiver to the 2 wires from the Gas Control Valve insuring you match the wire colors Place the receiver on the fireplace flo...

Страница 20: ...rrect all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment sh...

Страница 21: ...ly into firebox with the front pan facing forward Drill two 2 5 32 diameter holes approximately 1 deep Anchor the front pan to the floor using the 2 Concrete Attachment Screws Not Included See Fig 11...

Страница 22: ...og is marked with a number and this number will help you identify each log during installation Provided Logs 8 Fig 19 Installing Log 1 Fig 20 Installing Log 2 3 Fig 21 Installing Log 4 1 Insert log 1...

Страница 23: ...the unit and directions for the size and placement must be followed explicitly 1 Open the small bag and remove all of the ember material 2 Tear the material into rectangular shapes approximately 1 2...

Страница 24: ...ob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in fire or explosion D Do not use this appliance if any part has be...

Страница 25: ...rol knob 6 With control knob depressed push down on the ignitor button until the pilot lights The pilot s location is behind log 3 near the center of the burner See Fig 27 7 Keep control knob depresse...

Страница 26: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 27: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 28: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 29: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 30: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 31: ...rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which re...

Страница 32: ...cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 30 turn heater off see To Turn Off Gas to Appliance page 24 see Troubleshooting page 34 WARNING Do not allow fan...

Страница 33: ...a qualified service person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30...

Страница 34: ...of dust dirt lint or pet hair with a soft cloth or vacuum cleaner nozzle 5 Blow air into the primary air holes on the orifice holder 6 In case any large clumps of dust have now been pushed into the bu...

Страница 35: ...trode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad push button ignitor 7 Bad Battery 1 Replace electrode 2 Replace electrode 3 Replace ignitor cabl...

Страница 36: ...an burner see Care and Maintenance page 25 26 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Cl...

Страница 37: ...ective Moisture conden sation noticed on windows 1 Not enough combustion ventilation air Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit 1 Residues f...

Страница 38: ...g 3 1 H 010B H 003B 1 4 Log 4 1 H 0075 H 0075 1 5 Log 5 1 H 0139 H 0139 1 6 Log 6 1 H 0812 H 0812 1 7 Log 7 1 H 0370 H 0370 1 8 Log 8 1 H 0356 H 0356 2 Grate 1 GP289 01 GP290 01 3 Grate End Cap 1 GP28...

Страница 39: ...Y IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED...

Страница 40: ...Y IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED...

Отзывы: