background image

KEEP THIS WARRANTY

WARRANTY INFORMATION

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

099435-01
REV. H
5/94

LIMITED WARRANTY

COMFORT GLOW VENT-FREE NATURAL GAS HEATERS

DESA International warrants this product to be free from defects in materials and components for one year from the date
of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all
applicable instructions. To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required to
restore this heater to proper operating condition. Warranty part(s) MUST be obtained through authorized dealers of this
product and/or DESA International who will provide original factory replacement parts. Failure to use original factory
replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local
codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail
or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation.
Travel, diagnostic cost, labor, transportation and any and all such other costs related to repairing a defective heater will be
the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE
PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND
LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO (2) YEARS FROM THE DATE OF
FIRST PURCHASE; AND DESA INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE
PRICE OF THE PRODUCT AND DESA INTERNATIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES
WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or
consequential damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply
to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

Содержание CGP16R

Страница 1: ...or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do...

Страница 2: ...burns fire explosion electrical shock and carbon monoxide poisoning WARNING ICON G 001 DANGER Carbon monoxide poisoning may lead to death Carbon Monoxide Poisoning Early signs of carbon monoxide pois...

Страница 3: ...entilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is available See Fresh Air for Combus tion and...

Страница 4: ...s or other sources to light heater LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSI Z223 1 also k...

Страница 5: ...The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unus...

Страница 6: ...r Gas furnace ___________________ BTU Hr Vented gas heater ___________________ BTU Hr Gas fireplace logs ___________________ BTU Hr Other gas appliances ___________________ BTU Hr Total ______________...

Страница 7: ...or on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see option 3 Figure 2 WARNING ICON G 001 WARNING Rework worksheet adding the space of...

Страница 8: ...en to the outdoors These spaces include attics and crawl spaces Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation gr...

Страница 9: ...nces shown in Figure 4 page 10 If you can provide greater clearances from floor ceiling and joining wall You can locate heater on floor away from a wall An optional floor mounting stand is needed Purc...

Страница 10: ...NING ICON G 001 CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locate heater where moving vehicle will not hit it For convenience and...

Страница 11: ...vides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to wall anchor This method allows you to attach mounting bracket to hollow walls wall areas betwe...

Страница 12: ...holes drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to wall anchor method For attachin...

Страница 13: ...talling Bottom Mounting Screws 1 Locate two bottom mounting holes These holes are near bottom on back panel of heater see Figure 11 2 Mark screw locations on wall 3 Remove heater from mounting bracket...

Страница 14: ...ou do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing...

Страница 15: ...t heater and its individual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve wa...

Страница 16: ...ming show a leak 4 Correct all leaks at once PRESSURE TESTING HEATER GAS CONNECTIONS 1 Open manual shutoff valve see Figure 14 2 Open propane supply tank valve 3 Make sure control knob of heater is in...

Страница 17: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician or gas supplier Force or attempted repair may result i...

Страница 18: ...d turn it counterclockwise C clockwise to the PILOT IGN position This will light pilot Note You will hear a loud click when the control knob reaches the PILOT IGN position If pilot does not light turn...

Страница 19: ...st heating levels by using the manual shut off valve GRH OV 023A BURNER PATTERNS VANGUARD NON T STAT PLAQUE MODELS LOW OFF PILOT IGN MED OFF PILOT IGN HIGH OFF PILOT IGN OFF OFF HIGH MED LOW Control K...

Страница 20: ...e control knob TO TURN OFF GAS TO APPLIANCE If pilot flame pattern is incorrect as shown in Figure 20 turn heater off see To Turn Off Gas to Appliance above see Troubleshooting pages 22 through 25 INS...

Страница 21: ...s incorrect as shown in Figure 22 turn heater off see To Turn Off Gas to Appliance page 20 see Troubleshooting pages 22 through 25 Figure 21 Correct Burner Flame Pattern INSPECTING BURNER Continued BU...

Страница 22: ...passageways of heater clean Inspect these areas of heater before each use Have heater inspected yearly by a qualified service person Heater may need more frequent cleaning due to excessive lint from...

Страница 23: ...ROBLEM When control knob is pressed in and turned to the PILOT IGN position there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released POSSIBLE CAUSE...

Страница 24: ...et between locked positions 1 Residues from manu facturing processes 1 Metal expanding while heating or contracting while cooling REMEDY 1 Clean burner orifice s see Cleaning and Maintenance page 22 o...

Страница 25: ...age 2 Control valve defec tive 1 Foreign matter be tween control valve and burner 2 Gas leak See Warn ing statement at top of page OBSERVED PROBLEM Heater produces unwanted odors Heater shuts off in u...

Страница 26: ...RVICE HINTS REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of thi...

Страница 27: ...82 215 696 2670 1 800 368 0803 LaPorte s Parts Service 2444 N 5th Street Hartsville SC 29550 803 332 0191 Cans Unlimited Inc P O Box 645 Taylor SC 29687 All States 803 879 3009 1 800 845 5301 Dealers...

Страница 28: ...HEATER EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model CGP16R 13 15 13 14 ODS PILOT BURNER ASSEMBLY A B C 13 1 13 2 13 3 13 10 13 4 13 5 13 6 13 7 13 8 13 9 13 12 13 13 13 11 1 2 3 11 6 4 8 5 6 7 12 1...

Страница 29: ...8 2 11 098455 01 Cabinet Assembly 1 12 098324 01 Control Knob 1 13 See Detail Burner Assembly 1 13 1 099218 01 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 01 Injector 3 13 4 099048 01 Tub...

Страница 30: ...ATER EXPLODED VIEW ILLUSTRATED PARTS BREAKDOWN Model CGP26C 13 15 13 14 ODS PILOT E D C 13 1 13 2 13 3 13 9 13 4 13 5 13 7 13 6 13 8 13 10 13 12 13 13 13 11 B A 1 2 3 11 6 13 4 8 5 6 7 12 9 10 14 BURN...

Страница 31: ...0 M11084 38 Screw 8 x 3 8 2 11 098456 01 Cabinet Assembly 1 12 098324 01 Control Knob 1 13 See Detail Burner Assembly 1 13 1 099218 02 Burner 1 13 2 098508 01 Valve Retainer Nut 1 13 3 099056 01 Injec...

Страница 32: ...ed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear...

Отзывы: