1.

STOP! Read the safety information,
column 2.

2.

Make sure manual shutoff valve is
fully open.

3.

Press in and turn control knob clock-
wise 

Clockwise

 to the OFF position.

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open damper or window to vent
smell. This will only last a few hours.

FOR YOUR

SAFETY READ

BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

LIGHTING

INSTRUCTIONS

 WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you oper-
ate heater with doors closed,
heat buildup inside fireplace will
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

The thermostat control knob can be set to
any comfort level between Hi and Lo.
The thermostat will gradually modulate
the heat output and flame height from
higher to lower settings, or pilot, in order
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

Note:

 Selecting the Hi setting with the

control knob will cause the burners to
remain fully on, without modulating down
in most cases.

Variable Manually-Controlled
Models

OPERATING
HEATER

Continued

TO TURN OFF GAS

 TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise

 to the OFF position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn control knob clockwise

 to the PILOT position.

THERMOSTAT

CONTROL OPERATION

MANUAL LIGHTING

PROCEDURE

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 14.

Note:

 Home owners generally prefer to

operate their heater with the chimney
damper closed. This will put all the heat
into the room. However, there may be
times you will desire the full flames of the
High heat setting but will find the heat
output excessive. You can open the chim-
ney damper (if you have one) fully or
partially to release some of the heat.

 WARNING: Damper handle

will be hot if heater has been
running.

Continued

Figure 22 - Control Knob and Ignitor But-
ton Location

Control Knob

Ignitor Button

Содержание CGG2618N

Страница 1: ...nd Ventilation section page 4 in this manual WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do...

Страница 2: ...sed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking c...

Страница 3: ...ters State and local codes in some areas prohibit the use of vent free heaters Non thermostat models may also be operated as a vented decorative ANS Z21 60 product by opening flue damper SAFETY PILOT...

Страница 4: ...ion However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outsid...

Страница 5: ...rect vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________...

Страница 6: ...e two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces...

Страница 7: ...air may cause mildew to form from too much moisture See Air for Com bustion and Ventilation pages 4 through 6 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install...

Страница 8: ...K No hood accessory needed Less than 8 Noncombustiblematerialmustbeextendedtoatleast8 See Between 8 and 12 above If you cannot extend material youmustoperateheaterwithfluedamperopen Figure 5 Heat Resi...

Страница 9: ...7 when using hood Mantel Shelf INSTALLATION Continued Figure 7 Minimum Mantel Clearances When Using Hood Mantel Shelf Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inche...

Страница 10: ...e floor If not heater will move when you adjust controls Moving heater may cause a gas leak INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION Note When used as a vented heater appli ance must be...

Страница 11: ...de a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 Apply pipe joint sealant lightly to male t...

Страница 12: ...orrect all leaks at once WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once WARNING Test all gas...

Страница 13: ...ddle log 2 see Figure 18 Make sure notches on bottom rest on grate prongs 4 Finally place top log 4 over bottom middle log 2 by matching the notches under log 4 with the raised blocks of log 2 see Fig...

Страница 14: ...the front burner If needed keep press ing ignitor button until pilot lights Note If pilot does not stay lit con tact a qualified service person or gas supplier for repairs Until repairs are made light...

Страница 15: ...s heater with glassdoorsclosed Ifyouoper ate heater with doors closed heatbuildupinsidefireplacewill cause glass to burst Also if fireplace opening has vents at the bottom you must open the vents befo...

Страница 16: ...ilot does not light contact a qualified service person or gas sup plier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Light ing Procedure column 3 7 Ke...

Страница 17: ...air to mix with the gas This provides a clean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec...

Страница 18: ...amaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind...

Страница 19: ...fter a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed...

Страница 20: ...k SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Thermostat sensing bulb needs to be r...

Страница 21: ...not mount sensing bulb until step 5 If you have a masonry fire place see Figure 33 for location If you have a factory built metal fire place see Figure 34 for location If your fireplace has glass doo...

Страница 22: ...Natural Gas Only Natural Gas Only Natural Gas Only Natural Gas Only Ignition Piezo Piezo Piezo Piezo Pressure 3 4 W C 3 4 W C 3 4 W C 3 4 W C Inlet Gas Pressure in of water Maximum 10 5 10 5 10 5 10 5...

Страница 23: ...11 Parts Department East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 Parts Department Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1...

Страница 24: ...AL GAS LOG HEATER 103424 ILLUSTRATED PARTS BREAKDOWN Variable Manually Controlled Models CGG2618N CGG3324N CGG3630N 18 20 19 26 25 21 21 27 5 6 7 8 29 29 25 10 9 11 12 13 15 22 23 27 1 27 2 24 7 1 7 2...

Страница 25: ...098867 09 Gas Regulator 1 13 M11084 38 M11084 38 M11084 38 Screw 2 14 101011 01 101011 02 101011 03 Inlet Tube 1 15 098354 01 098354 01 098354 01 Control Knob 1 16 098462 03 098462 03 098462 03 Contr...

Страница 26: ...ED NATURAL GAS LOG HEATER 103424 ILLUSTRATED PARTS BREAKDOWN Thermostat Controlled Model CGG3324NT 5 6 25 6 7 8 9 10 11 8 8 29 13 12 13 14 15 16 18 17 19 24 26 27 7 1 7 2 29 22 23 21 28 20 30 10 1 10...

Страница 27: ...999 05 Rear Burner Assembly 1 12 101331 08 Base Assembly with decals 1 13 098271 06 Ignitor Cable 1 14 102445 01 Piezo Ignitor 1 15 098867 09 Gas Regulator 1 16 M11084 38 Screw 2 17 102810 02 Inlet Tu...

Страница 28: ...r costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY...

Отзывы: