We recommend that you install a sediment trap in supply line as
shown in Figure 24. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and fireplace.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into fireplace controls. If sediment trap is not installed
or is installed wrong, fireplace may not run properly.

* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 29.

Figure 24 - Gas Connection

INSTALLATION

Continued

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

PROPANE/LP
From External Regulator
(11" W.C. to 14" W.C.
Pressure)

NATURAL
From Gas Meter (5" W.C.
to 10.5" W.C. Pressure)

3" Minimum

Pipe

Cap

Tee

Nipple

Joint

Sediment Trap

Figure 25 - Removing Log Base Assembly From Fireplace

CONNECTING EQUIPMENT SHUTOFF VALVE
TO HEATER CONTROL

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1.

Remove fireplace screen. Remove two screws that hold fire-
place screen in place for shipping. These screws are located
near top of screen. Discard screws. Lift fireplace screen up
and pull out to remove.

2.

Remove screws that attach branch support to fireplace (see
Figure 25). Carefully lift up branch support and remove from
fireplace (see Figure 25).

3.

Route flexible gas line, included, from fireplace control to
equipment shutoff valve through side or rear access holes
in outer casing.

NOTICE: Most building codes do not permit con-
cealed gas connections. A flexible gas line is pro-
vided to allow accessibility from the fireplace (see
Figure 25). The flexible gas supply line connection to
the equipment shutoff valve should be accessible.

Figure 26 - Attaching Flexible Gas Line to Equipment Shutoff
Valve

Branch
Support

Screen

Screen
Shipping
Screw

Shoulder
Screw

Flexible
Gas Line

4.

Apply pipe joint sealant lightly to male threads of gas connec-
tor attached to flexible gas line/equipment shutoff valve (see
Figure 26).

5.

Check all gas connections for leaks. See Checking Gas Con-
nections,
 page 16.

6.

Replace branch support back into fireplace. Feed flexible gas
line into fireplace base area while replacing branch support. Make
sure the entire flexible gas line is in fireplace base area. Reat-
tach branch support to fireplace with screws removed in step 2.

 CAUTION: Avoid damage to regulator. Hold gas

regulator with wrench when connecting it to gas
piping and/or fittings.

Flexible Gas Line from
Fireplace Gas Regulator
Provided with Fireplace

To Fireplace
Gas Regulator

Equipment Shutoff Valve
Provided by Installer

PROPANE/LP
To External
Regulator

NATURAL
To Gas Supply

INSTALLATION

Connecting to Gas Supply (Cont.)

Connecting Equipment Shutoff Valve to Heater Control

Содержание CGCFTN

Страница 1: ...nual for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier This appliance may be installed in...

Страница 2: ...y change to this fireplace or its controls can be dangerous WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create draf...

Страница 3: ...ned to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log curing and fireplace burning...

Страница 4: ...Figure 2 Removing Fireplace Hood IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE PACKAGING 1 2 Hood Cardboard Protective Fireplace End Wrap...

Страница 5: ...clothesdryers andfuelburningappliances drawairfromthehousetooperate Youmustprovideadequatefresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING AD...

Страница 6: ...ay be operated is smaller than that defined as an uncon fined space or if the building is of unusually tight construction provideadequatecombustionandven tilation air by one of the methods described i...

Страница 7: ...ls or ducts IMPORTANT Donotprovideopeningsforinletoroutletairintoattic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Or Remove Door into Ad...

Страница 8: ...e installed on a metal or wood panel extending the full width and depth of the fireplace LOCATING FIREPLACE WARNING Maintain the minimum clearances shown in Figures 7 and 8 If you can provide greater...

Страница 9: ...Studs Figure 10 Rough Opening for Installing in Corner WARNING If pre wiring do not connect wiring to any electrical source at this time Install fireplace electrical outlet and connect wiring to outl...

Страница 10: ...ARNING Do not allow noncombustible materials to cover any necessary openings like louvered slots WARNING Use only noncombustible mortar or adhesives when overlapping the front facing with noncombustib...

Страница 11: ...s see Figure 13 page 10 16 Reinstall top louvers ASSEMBLING BRASS TRIM Brass trim shipped with mantel 1 Remove packaging from three remaining pieces of brass trim 2 Locate two adjusting plates with se...

Страница 12: ...one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to swit...

Страница 13: ...supply 2 Follow steps 2 through 6 in Installing Blower Assembly begin ning on page 12 Also remove black wire from middle switch terminal 2 3 Remove black plastic strain relief and power cord from swit...

Страница 14: ...the appliance Checkyourbuildingcodesforanyspecialrequirementsforlocating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant fr...

Страница 15: ...ews that attach branch support to fireplace see Figure 25 Carefully lift up branch support and remove from fireplace see Figure 25 3 Route flexible gas line included from fireplace control to equipmen...

Страница 16: ...k detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once WARNING Test all gas piping and connections internal and external to unit for leaks after installing or servicin...

Страница 17: ...em and any gas control which has been under water Control Knob WARNING You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is installed before running firepla...

Страница 18: ...ob clockwise Clockwise to the PILOT position THERMOSTAT CONTROLOPERATION MANUALLIGHTING PROCEDURE INSPECTING BURNER Thermocouple Pilot Burner Figure 32 Correct Pilot Flame Pattern Propane LP Shown Fig...

Страница 19: ...m pressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the direc tions on the can If you don t follow directions on the can you could d...

Страница 20: ...7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ig...

Страница 21: ...r orifice 1 When heated vapors from furniture pol ish wax carpet cleaners etc may turn into white powder residue REMEDY 1 Clean burner see Cleaning and mainte nance page 19 or replace burner orifice 2...

Страница 22: ...leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation...

Страница 23: ...your warranty coverage for parts replaced under warranty PARTSUNDERWARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Techn...

Страница 24: ...www desatech com 24 12 ILLUSTRATED PARTS BREAKDOWN MODELS CGCFTP AND CGCFTN 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 16 15 18 24 28 5 41 34 25 20 4 35 12 24 12 1 2...

Страница 25: ...098303 02 Regulator Screw 2 19 Outer Shell Base 1 20 102649 02 102649 02 Branch Support 1 21 099415 09 099415 10 Gas Regulator 1 22 102875 01 102875 01 Regulator Bracket 1 23 101381 01 101381 01 Valv...

Страница 26: ...397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department sales portableheaterparts com te...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111044 01D For more information visit www desatech com For more information visit www desatech com 28 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...nstructions to make it easy to clean all critical areas of your appliance BRASS TRIM KIT GA6095 Optionalfour sidedbrasstrimkitforbuilt ininstallations Provides a finished appearance covering rough edg...

Страница 30: ...proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the respo...

Отзывы: