background image

111044-01D

For more information, visit www.desatech.com

For more information, visit www.desatech.com

10

13"

16"

19"

21"

1

/

2

"

6"

8"

10"

Note:

All vertical
measurements
are from top of
fireplace
opening to 
bottom of
mantel shelf. All
measurements
are in inches.

MANTEL CLEARANCES FOR BUILT-IN
INSTALLATION

If placing mantel above built-in fireplace, you must meet minimum
clearance between mantel shelf and top of fireplace opening.

Figure 12 - Minimum Mantel Clearances for Built-In Installation

Mantel Shelf

Side of
Firebox

INSTALLATION

Continued

NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard.
Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini-
mum clearances shown, you must do one of the
following:
• raise the mantel to an acceptable height
• remove the mantel

 WARNING: Do not allow any combustible materi-

als to overlap the firebox front facing.

IMPORTANT:

 Noncombustible materials such as brick, tile, etc.

may overlap the front facing, but should never cover any necessary
openings like louvered slots.

 WARNING: Do not allow noncombustible materials

to cover any necessary openings like louvered slots.

 WARNING: Use only noncombustible mortar or

adhesives when overlapping the front facing with
noncombustible facing material.

 WARNING: Never modify or cover the louvered

slots on the front of the firebox.

Note: All vertical
measurements are
from top of fireplace
opening to bottom of
mantel shelf. All
measurements are in
inches.

OPTIONAL MANTEL INSTALLATION

Note:

 Refer to instructions provided with the mantel for assembly

instructions. Refer to instructions below for system installation.
Refer to instructions on page 4 for firebox assembly. Blower
accessory should be installed if it is being used (see Installing
Blower Accessory GA3450T,
 pages 11 through 13).

1.

Unscrew four brass screws that attach top louver to fireplace.
Remove louver from fireplace and set aside.

2.

Place fireplace on wood base.

3.

Place mantel around fireplace/base assembly.

4.

Assemble brass trim kit. See Assembling Brass Trim, page 11.

5.

Firmly snap brass trim kit on shoulder screws. Shoulder screws
are located on fireplace cabinet (see Figure 13).

Shoulder Screws

Assembled Brass Trim

Hole for 3"
Wood Screw
for Attaching
Fireplace to
Wooden Base

Hole for 3"
Wood Screw
for Attaching
Fireplace to
Mantel

Figure 13 - Attaching Brass Trim to Fireplace

INSTALLATION

Built-In Fireplace Installation (Cont.)
Mantel Clearances for Built-In Installation
Optional Mantel Installation

Содержание CGCFTN

Страница 1: ...nual for correct installa tion and operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier This appliance may be installed in...

Страница 2: ...y change to this fireplace or its controls can be dangerous WARNING Do not allow fans to blow directly into the fireplace Avoid any drafts that alter burner flame patterns Ceiling fans can create draf...

Страница 3: ...ned to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log curing and fireplace burning...

Страница 4: ...Figure 2 Removing Fireplace Hood IMPORTANT THIS PACKAGE CONTAINS A FIREPLACE HOOD UNWRAP CARTON AND REMOVE HOOD BEFORE DISCARDING PROTECTIVE PACKAGING 1 2 Hood Cardboard Protective Fireplace End Wrap...

Страница 5: ...clothesdryers andfuelburningappliances drawairfromthehousetooperate Youmustprovideadequatefresh air for these appliances This will insure proper venting of vented fuel burning appliances PROVIDING AD...

Страница 6: ...ay be operated is smaller than that defined as an uncon fined space or if the building is of unusually tight construction provideadequatecombustionandven tilation air by one of the methods described i...

Страница 7: ...ls or ducts IMPORTANT Donotprovideopeningsforinletoroutletairintoattic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent Or Remove Door into Ad...

Страница 8: ...e installed on a metal or wood panel extending the full width and depth of the fireplace LOCATING FIREPLACE WARNING Maintain the minimum clearances shown in Figures 7 and 8 If you can provide greater...

Страница 9: ...Studs Figure 10 Rough Opening for Installing in Corner WARNING If pre wiring do not connect wiring to any electrical source at this time Install fireplace electrical outlet and connect wiring to outl...

Страница 10: ...ARNING Do not allow noncombustible materials to cover any necessary openings like louvered slots WARNING Use only noncombustible mortar or adhesives when overlapping the front facing with noncombustib...

Страница 11: ...s see Figure 13 page 10 16 Reinstall top louvers ASSEMBLING BRASS TRIM Brass trim shipped with mantel 1 Remove packaging from three remaining pieces of brass trim 2 Locate two adjusting plates with se...

Страница 12: ...one of the round holes in the rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 18 8 Reconnect red wire to switch position 3 Reconnect blue wire to swit...

Страница 13: ...supply 2 Follow steps 2 through 6 in Installing Blower Assembly begin ning on page 12 Also remove black wire from middle switch terminal 2 3 Remove black plastic strain relief and power cord from swit...

Страница 14: ...the appliance Checkyourbuildingcodesforanyspecialrequirementsforlocating equipment shutoff valve to fireplaces Apply pipe joint sealant lightly to male NPT threads This will prevent excess sealant fr...

Страница 15: ...ews that attach branch support to fireplace see Figure 25 Carefully lift up branch support and remove from fireplace see Figure 25 3 Route flexible gas line included from fireplace control to equipmen...

Страница 16: ...k detection fluid to gas joints Bubbles forming show a leak 4 Correct all leaks at once WARNING Test all gas piping and connections internal and external to unit for leaks after installing or servicin...

Страница 17: ...em and any gas control which has been under water Control Knob WARNING You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is installed before running firepla...

Страница 18: ...ob clockwise Clockwise to the PILOT position THERMOSTAT CONTROLOPERATION MANUALLIGHTING PROCEDURE INSPECTING BURNER Thermocouple Pilot Burner Figure 32 Correct Pilot Flame Pattern Propane LP Shown Fig...

Страница 19: ...m pressed air in a can You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the direc tions on the can If you don t follow directions on the can you could d...

Страница 20: ...7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 2 Reconnect ignitor cable 3 Replace ignitor cable 4 Replace piezo ig...

Страница 21: ...r orifice 1 When heated vapors from furniture pol ish wax carpet cleaners etc may turn into white powder residue REMEDY 1 Clean burner see Cleaning and mainte nance page 19 or replace burner orifice 2...

Страница 22: ...leak SeeWarning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation...

Страница 23: ...your warranty coverage for parts replaced under warranty PARTSUNDERWARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating Products Techn...

Страница 24: ...www desatech com 24 12 ILLUSTRATED PARTS BREAKDOWN MODELS CGCFTP AND CGCFTN 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 16 15 18 24 28 5 41 34 25 20 4 35 12 24 12 1 2...

Страница 25: ...098303 02 Regulator Screw 2 19 Outer Shell Base 1 20 102649 02 102649 02 Branch Support 1 21 099415 09 099415 10 Gas Regulator 1 22 102875 01 102875 01 Regulator Bracket 1 23 101381 01 101381 01 Valv...

Страница 26: ...397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department sales portableheaterparts com te...

Страница 27: ...ed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35 000 to 4...

Страница 28: ...111044 01D For more information visit www desatech com For more information visit www desatech com 28 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 29: ...nstructions to make it easy to clean all critical areas of your appliance BRASS TRIM KIT GA6095 Optionalfour sidedbrasstrimkitforbuilt ininstallations Provides a finished appearance covering rough edg...

Страница 30: ...proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the respo...

Отзывы: