background image

7

104306

OWNER’S MANUAL

INSTALLATION

NOTICE: A qualified service per-
son must install heater. Follow
all local codes.

 WARNING: Before installing

in a solid fuel burning fireplace,
the chimney flue and firebox must
be cleaned of soot, creosote,
ashes and loose paint by a quali-
fied chimney cleaner. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue for damage. If
damaged, operate heater with flue
damper closed.

 WARNING: Seal any fresh air

vents or ash clean-out doors lo-
cated on floor or wall of fireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.

 WARNING: Never install the

heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

 CAUTION: This heater cre-

ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities  (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

IMPORTANT:

 Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

CHECK GAS TYPE

Use only natural gas. If your gas supply is
not natural gas, do not install heater. Call
dealer where you bought heater for proper
type heater.

NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented configuration.
Check your state or local codes.

 WARNING: Make sure the re-

mote selector switch is in the OFF
position before installing heater.

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

INSTALLATION AND
CLEARANCES (Vent-Free
Operation Only)

 WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This
will ensure safe installation into a masonry
fireplace or factory-built U.L. 127 listed
vent-free firebox.

Minimum Wall and Ceiling
Clearances (see Figure 4)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

Figure 4 - Minimum Clearance to Wall and
Ceiling

Continued

LOG SIZING REQUIREMENTS

Minimum Firebox Size

Rear

Width

Log

Front At 14"

Size Height Depth Width Depth

24"

17"

14"

28"

21"

30"

17"

14"

34"

24"

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

24"

16"

42"

42"

16"

Left and Right

Sides

Содержание CGB3924NR

Страница 1: ...24 and 30 Remote Controlled Model P I L O T O F F O N LO REMOTE OFF HI OWNER S OPERATION AND INSTALLATION MANUAL WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Donotstoreorusegasolineorother flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS...

Страница 2: ...r 7 You must operate this heater with a fire place screen in place Make sure fire place screen is closed before running heater 8 This log heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial operation slight smoking may occur due to log curing and heater burning manufactur ing residues 9 Do not allow fans to blow d...

Страница 3: ...tteries or other sources to light heater 1 Remove logs and heater base assem bly from carton Note Do not pick up heater base assembly by burners This could damage heater Always handle base assembly by grate 2 Remove all protective packaging ap plied to logs and heater for shipment 3 Check all items for any shipping dam age If damaged promptly inform dealer where you bought heater UNPACKING PRODUCT...

Страница 4: ...stion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been a...

Страница 5: ...direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can support _________________ Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 79 000 Btu Hr actual amount of Btu Hr used The...

Страница 6: ...From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlledpowe...

Страница 7: ...entilation pages 4 through 6 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install heater Call dealer where you bought heater for proper type heater NOTICE Stateorlocalcodesmay onlyallowoperationofthisappli ance in a vented configuration Check your state or local codes WARNING Make sure the re moteselectorswitchisintheOFF position before installing heater NOTICE ...

Страница 8: ...ce opening Non combus tible materials such as slate marble tile etc must be at least 1 2 inch thick With sheet metal you must have non combus tible material behind it Non combustible materialmustextendatleast8inchesup for all models If non combustible material is less than 12 you must install the fireplace hood accessory 24 and 30 models only Even if non combustible material is more than 12 you ma...

Страница 9: ...rances shown you must do one of the following operate the logs only with the flue damper open raise the mantel to an accept able height remove the mantel 14 Min Combustible Material Non Combustible Material Hearth 5 Min Combustible Material Minimum Non Combustible Material 8 Min 12 15 18 All minimum distances are in inches Log Set 18 24 30 Models 20 2 1 2 6 8 10 12 Distances to Underside of Mantel...

Страница 10: ...ing Masonry Screw Mounting Flanges Installation Items Needed hardware package provided with heater approved flexible gas hose not provided if allowed by local codes sealant resistant to propane LP gas not provided electric drill with 3 16 masonry drill bit two 2 9 volt alkaline batteries not in cluded 1 Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulat...

Страница 11: ...ocate sedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly WARNING Never connect heater to private non utility gas wells This gas is commonly known as well head gas Figure 12 Gas Connection Purchase the optional A...

Страница 12: ...ery housing 3 Replace battery cover onto remote con trol unit Figure 15 Installing 9 Volt Battery In Receiver Battery Cover Terminal Wires 9 Volt Battery Remote Control Unit Battery Housing Receiver Terminal Wires 9 Volt Battery Figure 16 Installing Battery In Hand Held Remote control Unit TestPressuresEqualToorLessThan 1 2 PSIG 1 Close manual shutoff valve see Fig ure 13 2 Pressurize supply pipin...

Страница 13: ...ase and the cutout area is centered over the burner U bend 3 Locate the recesses on the back of the front log 3 Fit these recesses be tween the posts of the grate base see Figure 19 4 Locate the notches in the bottom of the crossover log 4 Place the crossover log on top of the middle log and front log Make sure the notches of the cross over log lines up with rectangular knobs on top of the middle ...

Страница 14: ...e that no flame comes in contact with any log If so repo sition logs according to the log installation instructions in this manual Flames contacting logs will create soot 1 Place the base of the middle log 1 in the U shaped slots of the grate base The cutout on the right of the middle log should bit over the burner see Fig ure 21 Make sure the front of the middle log is resting on the tabs of the ...

Страница 15: ...r window to vent smell Thiswillonlylastafewhours Note Homeowners generally prefer to operate their heater with the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the Hiheatsettingbutwillfindtheheatoutput excessive You can open the chimney damper if you have one fully or partially to release some of the heat OPERATING HEA...

Страница 16: ...rs and keep the pilot lit by doing one of the following Turn control knob clockwise to the PILOT position UseremotecontrolmanualOFFbutton Set remote selector switch in the OFF position Ignitor Electrode Pilot Burner THERMOSTAT CONTROL OPERATION The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO The Burners will turn on and off automati cally...

Страница 17: ...ctedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting pet hair etc ODS PILOT AND BURNER Use a vacuum cleaner or small soft bristled brush to clean LOGS If you remove logs for cleaning refer to Installing Logs pages 13 and 14 to prop erly replace logs Replace log s if broken or chipped dime sized or larger BURNER PRIMARY AIR HOLE Air is d...

Страница 18: ...re B Dirty or partially clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replac...

Страница 19: ...ge 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observe minimum installation clear ances see pages 7 through 9 4 Clean burner see Cleaning and Mainte nance page 17 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaners or similar products 1 ...

Страница 20: ... PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is common with most heaters If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products whi...

Страница 21: ...ater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your local natural gas supplier SERVICE HINTS WIRING DIAGRAM Receiver White On Off Remote Red Red White Thermopile Gas Control TPTH TH TPTH TP ACCESSORIES Purchase these fireplace accessories from your local dealer If they can not supply these accessories either contact your near est Parts Central see ...

Страница 22: ...B3924NR and CGB3930NR ILLUSTRATED PARTS BREAKDOWN CGD3924NR 7 16 16 17 25 16 3 2 1 4 11 21 10 9 12 15 8 19 18 20 6 14 5 13 27 26 26 RE MOTE OFF ON 22 23 24 O F F P I L O T O N H I L O O F F P I L O T O N H I L O AU TO MA N OF F ST AT US ON LO HI TE MP 20 ...

Страница 23: ...02772 01 Burner 1 13 099387 12 Pilot Tube Valve to regulator 1 14 103781 01 Gas Control Valve 1 15 103345 01 Lower Bracket 1 16 M11084 38 Screw 8 x 38 7 17 102775 06CK Painted Base Assembly 1 18 098271 07 Ignitor Cable 1 19 102445 01 Piezo Ignitor 1 20 103823 01 Remote Set Incl Transmitter 1 21 104099 01 Heat Shield 1 22 098304 01 Screw 2 23 103784 02 Flame Adjustment Knob 1 24 103784 01 Off Pilot...

Страница 24: ...R and CGB3930NR ILLUSTRATED PARTS BREAKDOWN CGB3924NR CGB3930NR 28 16 16 17 25 16 5 4 1 2 3 11 21 10 9 12 15 8 19 18 20 7 14 6 13 27 26 26 RE MOTE OFF ON 22 23 24 O F F P I L O T O N H I L O O F F P I L O T O N H I L O AU TO MA N OF F ST AT US ON LO HI TE MP 20 ...

Страница 25: ...CK 102775 06CK Painted Base Assembly 1 18 098271 07 098271 07 Ignitor Cable 1 19 102445 01 102445 01 Piezo Ignitor 1 20 103823 01 103823 01 Remote Set Incl Transmitter 1 21 104099 01 104099 01 Heat Shield 1 22 098304 01 098304 01 Screw 2 23 103784 02 103784 02 Flame Adjustment Knob 1 24 103784 01 103784 01 Off Pilot On Knob 1 25 M12461 26 M12461 26 Screw Hex Slt Wsr 10 32 x 38 4 26 100609 01 10060...

Страница 26: ... Main Street Kansas City MO 64108 KS MO AR 816 842 3911 East Coast Energy Products 707 Broadway W Long Branch NJ 07764 732 870 8809 1 800 755 8809 Tarantin Tank Co P O Box 6129 Freehold NJ 07728 908 780 9340 1 800 922 0724 Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 All States 937 258 3721 OH 1 800 762 3426 Halco Enterprises 208 Carter Drive Unit 21 West Chester PA 19382 610 4...

Страница 27: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Страница 28: ...ch other costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 2 YEARS ON ALL...