Comfort Glow CF26PR Скачать руководство пользователя страница 7

7

105442

OWNER’S MANUAL

INSTALLATION

Note: 

Your Comfort Glow fireplace is de-

signed to be used in zero clearance installa-
tions. Wall or framing material can be placed
directly against any exterior surface of your
fireplace, except where standoff spacers are
integrally attached. If standoff spacers are
attached to your fireplace, these spacers can
be placed directly against wall or framing
materials.

Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 8).

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install fireplace.
Call dealer where you bought fireplace for
proper type fireplace.

INSTALLATION ITEMS

Before installing fireplace, make sure you
have the items listed below.

• external regulator (supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• ground joint union

• sediment trap

• tee joint

• pipe wrench

• test gauge connection*

 WARNING: A qualified ser-

vice person must install fireplace.
Follow all local codes.

You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels. 

IMPORTANT:

Only use optional cabinet or corner man-
tels specified in this manual. Purchase the
optional mantel from your dealer (see
Accessories, page 28).

 CAUTION: This fireplace cre-

ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls.

 WARNING: Never install the

fireplace
• in a bedroom or a bathroom
• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the fireplace

• as a fireplace insert
• in high traffic areas
• in windy or drafty areas

IMPORTANT:

 Vent-free fireplaces add mois-

ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Combus-
tion and Ventilation, 
pages 4 through 6.

LOCATING FIREPLACE

 WARNING: Maintain the mini-

mum clearances shown in Fig-
ures 4 and 5. If you can, provide
greater clearances from floor,
ceiling, and joining wall.

Figure 5- Mounting Clearances As Viewed
From Front of Fireplace Shown with
Optional Mantel

 CAUTION: If you install the

fireplace in a home garage
• fireplace pilot and burner must

be at least 18 inches above
floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fire-
place

• where there is easy access for operation,

inspection, and service.

• in coldest part of room.

An optional blower kit is available from
your dealer. See Accessories, page 28. If
planning to use blower, locate fireplace near
an electrical outlet.

Figure 4 - Mounting Clearances As Viewed
From Front of Fireplace Shown Built In
The Wall

6"

Minimum
From
Sides Of
Fireplace

Left
Side

CEILING

42" Minimum

FLOOR

Right
Side

Top Of
Mantel Can
Be Flush
With Wall

Left
Side

CEILING

Right
Side

42"

Minimum

NOTICE: This heater is intended
for use as  supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 28.

Note:

 If desired, purchase a four-sided brass

trim kit for built-in installations. See Acces-
sories, pag
e 28.

Continued

Содержание CF26PR

Страница 1: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor sphone Followthegassupplier s instructions If you cannot reac...

Страница 2: ...ock and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 Thi...

Страница 3: ...ludes one hardware packet 4 Checkfireplaceforanyshippingdamage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with a...

Страница 4: ...rlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven t...

Страница 5: ...Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ Btu Hr maximum the sp...

Страница 6: ...N Continued Figure 2 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ven...

Страница 7: ...t top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is beneficial installing firepla...

Страница 8: ...gas line to fireplace gas regulator See Connecting Fireplace to Gas Supply page 13 6 If the optional blower has been installed connect blower to electrical source Option one Route blower electrical co...

Страница 9: ...achmenttowall 9 Slide mantel around fireplace Be care ful not to damage wall or mantel Note All vertical measurements are from top of fireplace opening to bottom of mantel shelf 10 Adjust assembly to...

Страница 10: ...ss through lower opening to the left of the blower control shield see Figure 16 8 Insert the 4 wire harness into one of the round holes in the rear of the blower control shield and through the rectan...

Страница 11: ...pplied will not be used in built in installations Pop intheplasticsnapbushingfoundinhard warekitintotheholeleftbysupplycord strain relief 4 A licensed electrician must follow the wiring diagram in Fig...

Страница 12: ...n Figure 20 Pointing the vent down protects it from freezing rain or sleet Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hoo...

Страница 13: ...ssible Manual Shut Off Valve Flexible Gas Line from Fireplace Gas Valve Provided with Fireplace To Fireplace Gas Valve 2 Apply pipe joint sealant lightly to male threads of gas connector attached to f...

Страница 14: ...WARNING Neveruseanopen flame to check for a leak Apply a mixture of liquid soap and water toalljoints Bubblesformingshow a leak Correct all leaks at once CAUTION Make sure external regulator has been...

Страница 15: ...ling Receiver 1 Disconnect switch wires from the con trol valve 2 Remove screws and nuts 3 Remove switch plate see Figure 28 Discard after removing 4 Install remote receiver unit onto gas log heater b...

Страница 16: ...Volt Battery Not Included in Hand Held Remote Control Unit 1 Remove battery cover on back of re mote control unit 2 Attach terminal wires to the battery Place battery into the battery housing 3 Replac...

Страница 17: ...hand held remote ON button was on when selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not leave the selector switch in t...

Страница 18: ...ough 22 Pilot Burner Thermocouple INSPECTING BURNERS BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may become blocked with d...

Страница 19: ...lean burning flame Keep these holesclearofdust dirt andlint Cleanthese air inlet holes prior to each heating season Blocked air holes will create soot We rec ommend that you clean the unit every 2 500...

Страница 20: ...EMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base pa...

Страница 21: ...lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Obse...

Страница 22: ...noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Th...

Страница 23: ...t Cans Unlimited Inc P O Box 645 Taylor SC 29687 0013 All States 803 879 3009 1 800 845 5301 Parts Department Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Pa...

Страница 24: ...VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR O F F P I L O T O N H I L O O F F P I L O T O N H I L O 16 15 19 8 19 20 21 17 18 14 13 23 10 12 22 13 4 7 6 9 5 11...

Страница 25: ...1 7 099056 21 Burner Orifice Injector 1 8 099998 01 Switch 1 9 102980 01 Burner 1 10 099387 13 Pilot Tube 1 11 103781 02 Gas Control Valve 1 12 103345 02 Lower Bracket 1 13 M11084 38 Screw 8 x 38 7 1...

Страница 26: ...26 105442 VENT FREE PROPANE LP BAY FRONT FIREPLACE CF26PR ILLUSTRATED PARTS BREAKDOWN CF26PR 5 8 15 17 13 14 11 2 11 1 21 19 4 12 16 10 6 5 9 1 2 18 7 20 2 20 3 20 1 18 18 16 22 3 18 16 3 22...

Страница 27: ...11 Rivets 8 14 105262 01CK Louvered Door 1 15 105261 01CK Firebox Floor 1 16 098304 01 Screw 10 x 3 8 21 17 105256 01CK Bayfront Bottom Panel 1 18 M11084 26 Hex Head Screws 10 x 38 26 19 105513 01CV...

Страница 28: ...te assembly instructions in cluded Three sided brass trim kit included MANUAL SHUTOFF VALVE GA5010 Manual shutoff valve with 1 8 NPT tap THERMOSTATICALLY CONTROLLED BLOWER KIT GA3450T Provides better...

Страница 29: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 30: ...ance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of th...