OPERATING HEATER

For Your Safety Read Before Lighting

Lighting Instructions

OPERATING HEATER

FOR YOUR SAFETY READ

BEFORE LIGHTING

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone

in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.

 WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information above.

2.

Make sure equipment shutoff valve is fully open.

3.

Turn control knob clockwise 

 to the OFF position.

4.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information above. If you don’t smell
gas, go to the next step.

5.

Turn control knob counterclockwise 

 to the PILOT

position. Press in control knob for five (5) seconds (see Fig-
ure 19).

Figure 19 - Control Knob In The OFF Position (Piezo Ignitor
Shown)

PIL

OT

LO

OFF

HI

IGNITOR

Ignitor Button

Control Knob

 CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

Figure 20 - Pilot (actual pilot may vary)

Ignitor Electrode

Pilot Burner

Thermocouple

Note:

 You may be running this heater for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop up when released, contact a

qualified service person or gas supplier for repairs.

6.

With control knob pressed in, push down and release igni-
tor button (see Figure 19). This will light pilot. The pilot is
attached to the front of burner. The pilot can be seen through
the glass panel. If needed, keep pressing ignitor button until
pilot lights.

Note:

 If pilot does not stay lit, refer to Troubleshooting,

pages 17 through 19. Also contact a qualified service per-
son or gas supplier for repairs. Until repairs are made, light
pilot with match. To light pilot with match, see Manual
Lighting Procedure,
 page 14.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop up when released, contact a

qualified service person or gas supplier for repairs.

Note:

 If pilot goes out, repeat steps 3 through 7. This

heater has a safety interlock system. Wait one (1) minute
before lighting pilot again.

8.

Turn control knob counterclockwise 

 to desired

heating level. The main burner should light. Set control
knob to any heat level between HI and LO.

Содержание CBN20, CBP20, SBN20, SBP20, CB

Страница 1: ...G Improperinstallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinstallationand operational procedures For as sistanceoradditional...

Страница 2: ...r use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propane LP mod els only WARNING Do not use any accessory not ap proved for...

Страница 3: ...0 Turn off and let cool before servicing Only a qualified service person should service and repair heater 11 Operating heater above elevations of 4 500 feet could cause pilot outage 12 To prevent perf...

Страница 4: ...ction un lessprovisionsareprovidedforadequatecombustion and ventilation air Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home Unusually...

Страница 5: ...stion air from the outdoors and vents to the outdoors Example Gas water heater _____________ Btu Hr Vent free heater _____________ Btu Hr Total _____________ Btu Hr WARNING If the area in which the he...

Страница 6: ...rs Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the...

Страница 7: ...sene lamps etc in the air exist may discolor walls or cause odors WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flam ma...

Страница 8: ...g hole as shown in Figure 5 Mounting hole is located on lower left edge on back of heater Make sure the thermostat sensing bulb is pointing up Methods For Attaching Mounting Bracket To Wall Only use l...

Страница 9: ...screws until mounting bracket is firmly fastened to wall studs Figure 9 Folding Anchor Figure 10 Popping Open Anchor Wings For Thin Walls Figure 11 Mounting Heater Onto Mounting Bracket Mounting Brac...

Страница 10: ...or drill with 1 4 inch diam eter concrete drill bit 13 8 inches into floor Insert anchors com pletely into holes 4 Reposition heater with base feet over holes Secure base to floor with wood screws See...

Страница 11: ...e is too small undue loss of volume will occur Install sediment trap in supply line as shown in Figure 15 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped...

Страница 12: ...f valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 16 2 Pressurize supply piping system by eith...

Страница 13: ...or gas including near the floor If you smell gas STOP Fol low B in the safety information above If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position Pr...

Страница 14: ...the set temperature The control knob can be set to any heat level between HI and LO Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases Note The the...

Страница 15: ...ice person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommendusingcompressedairnogreaterthan30PSI Yourlocal computer s...

Страница 16: ...10 000 20 000 15 000 30 000 Type Gas Natural Only Natural Only Natural Only Natural Only Ignition Piezo Piezo Electronic Electronic Pressure Regulator Setting 3 W C 3 W C 3 W C 3 W C Inlet Gas Pressur...

Страница 17: ...ally clogged ODS pilot 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or...

Страница 18: ...ator 3 Clean burner see Cleaning and Main tenance page 15 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air...

Страница 19: ...SERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in O...

Страница 20: ...desatech com For more information visit www desatech com 20 ILLUSTRATED PARTS BREAKDOWN MODELS CBN20 CBP20 SBN20 SBP20 ILLUSTRATED PARTS BREAKDOWN Models CBN20 CBP20 SBN20 and SBP20 2 3 5 6 8 9 9 10...

Страница 21: ...94 08 Deflector Assembly 1 9 098271 09 098271 09 Ignitor Cable 1 10 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 Thermocouple Kit 1 12 103446 01...

Страница 22: ...more information visit www desatech com 22 ILLUSTRATED PARTS BREAKDOWN MODELS CBN20T CBP20T CBN30T CBP30T CBN20TK CBP20TK ILLUSTRATED PARTS BREAKDOWN Models CBN20T CBP20T CBN30T CBP30T CBN20TK and CB...

Страница 23: ...98271 09 098271 09 098271 09 098271 09 Ignitor Cable 1 10 098249 01 098249 01 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 11...

Страница 24: ...EAKDOWN MODELS CBT20NT CBT20PT CBT30NT CBT30PT ILLUSTRATED PARTS BREAKDOWN Models CBT20NT CBT20PT CBT30NT and CBT30PT 20 2 12 13 7 15 3 5 6 8 9 4 1 17 19 14 18 16 9 10 11 Alkaline Battery AA Battery P...

Страница 25: ...11 098271 11 098271 11 098271 11 Ignitor Cable 1 10 098249 01 098249 01 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 110186 0...

Страница 26: ...nal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does n...

Отзывы: