background image

107882-01H

For more information, visit www.desatech.com

For more information, visit www.desatech.com

11

11

INSTALLATION

Continued

INSTALLATION

Connecting To Gas Supply

For propane/LP gas, the installer must supply an external regulator.
The external regulator will reduce incoming gas pressure. You must
reduce incoming gas pressure to between 11 and 14 inches of water.
If you do not reduce incoming gas pressure, heater regulator damage
could occur. Install the external regulator with the vent pointing
down as shown in Figure 14. Pointing the vent down protects it from
freezing rain or sleet.

 WARNING: A qualified service person must con-

nect heater to gas supply. Follow all local codes.

 CAUTION: For propane/LP gas, never connect

heater directly to the propane/LP supply. This heater
requires an external regulator (not supplied). Install
the external regulator between the heater and pro-
pane/LP supply.

Typical Inlet Pipe Diameters

20,000 Btu/Hr Models - 3/8" or greater

30,000 Btu/Hr Models - 1/2" or greater

Installation must include equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from heater (see Figure 15).

IMPORTANT:

 Install an equipment  shutoff valve in an accessible

location. The equipment  shutoff valve is for turning on or shutting
off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged heater valves.

 CAUTION: Use only new, black iron or steel pipe.

Internally-tinned copper tubing may be used in certain
areas. Check your local codes. Use pipe of large
enough diameter to allow proper gas volume to heater.
If pipe is too small, undue loss of volume will occur.

Install sediment trap in supply line as shown in Figure 15. Locate
sediment trap where it is within reach for cleaning. Locate sediment
trap where trapped matter is not likely to freeze. A sediment trap
traps moisture and contaminants. This keeps them from going into
heater controls. If sediment trap is not installed or is installed wrong,
heater may not run properly.

IMPORTANT:

  Hold the pressure regulator with wrench when

connecting it to gas piping and/or fittings. Do not over tighten pipe
connection to regulator. The regulator body could be damaged.

 WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

 WARNING: This appliance requires a 3/8" NPT

(National Pipe Thread) inlet connection to the pres-
sure regulator.

IMPORTANT:

 For natural gas, check gas line pressure before

connecting heater to gas line. Gas line pressure must be no greater than
10.5 inches of water. If gas line pressure is higher, heater regulator
damage could occur.

 WARNING: For natural gas, never connect heater

to private (non-utility) gas wells. This gas is com-
monly known as wellhead gas.

CONNECTING TO GAS SUPPLY

Figure 14 - External Regulator With Vent Pointing Down

External
Regulator

Propane/LP
Supply
Tank

Vent
Pointing
Down

*  A CSA design-certified equipment shutoff valve with 1/8" NPT
tap is an acceptable alternative to test gauge connection. Purchase
the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessories, page 26.

Figure 15 - Gas Connection

Pressure
Regulator

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test

Gauge

Connection*

Tee
Joint

Pipe
Nipple

Cap

3/8" NPT
Pipe Nipple

Heater
Cabinet

Sediment
Trap

Equipment
Shutoff Valve *

3"
Minimum

Natural Gas
From Gas Meter
(5" W.C. to 10.5"
W.C. Pressure)

Propane/LP
From External
Regulator
(11" W.C. to 14"
W.C. Pressure)

Ground Joint Union

Note: Burner
bracket not
shown for
clarity

Содержание CBN20, CBP20, SBN20, SBP20, CB

Страница 1: ...G Improperinstallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinstallationand operational procedures For as sistanceoradditional...

Страница 2: ...r use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors propane LP mod els only WARNING Do not use any accessory not ap proved for...

Страница 3: ...0 Turn off and let cool before servicing Only a qualified service person should service and repair heater 11 Operating heater above elevations of 4 500 feet could cause pilot outage 12 To prevent perf...

Страница 4: ...ction un lessprovisionsareprovidedforadequatecombustion and ventilation air Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home Unusually...

Страница 5: ...stion air from the outdoors and vents to the outdoors Example Gas water heater _____________ Btu Hr Vent free heater _____________ Btu Hr Total _____________ Btu Hr WARNING If the area in which the he...

Страница 6: ...rs Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the...

Страница 7: ...sene lamps etc in the air exist may discolor walls or cause odors WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flam ma...

Страница 8: ...g hole as shown in Figure 5 Mounting hole is located on lower left edge on back of heater Make sure the thermostat sensing bulb is pointing up Methods For Attaching Mounting Bracket To Wall Only use l...

Страница 9: ...screws until mounting bracket is firmly fastened to wall studs Figure 9 Folding Anchor Figure 10 Popping Open Anchor Wings For Thin Walls Figure 11 Mounting Heater Onto Mounting Bracket Mounting Brac...

Страница 10: ...or drill with 1 4 inch diam eter concrete drill bit 13 8 inches into floor Insert anchors com pletely into holes 4 Reposition heater with base feet over holes Secure base to floor with wood screws See...

Страница 11: ...e is too small undue loss of volume will occur Install sediment trap in supply line as shown in Figure 15 Locate sediment trap where it is within reach for cleaning Locate sediment trap where trapped...

Страница 12: ...f valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 16 2 Pressurize supply piping system by eith...

Страница 13: ...or gas including near the floor If you smell gas STOP Fol low B in the safety information above If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position Pr...

Страница 14: ...the set temperature The control knob can be set to any heat level between HI and LO Selecting the HI setting will cause the burner to remain fully on without modulating down in most cases Note The the...

Страница 15: ...ice person We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommendusingcompressedairnogreaterthan30PSI Yourlocal computer s...

Страница 16: ...10 000 20 000 15 000 30 000 Type Gas Natural Only Natural Only Natural Only Natural Only Ignition Piezo Piezo Electronic Electronic Pressure Regulator Setting 3 W C 3 W C 3 W C 3 W C Inlet Gas Pressur...

Страница 17: ...ally clogged ODS pilot 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Replace pilot assembly 2 Replace pilot assembly 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or...

Страница 18: ...ator 3 Clean burner see Cleaning and Main tenance page 15 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air...

Страница 19: ...SERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in O...

Страница 20: ...desatech com For more information visit www desatech com 20 ILLUSTRATED PARTS BREAKDOWN MODELS CBN20 CBP20 SBN20 SBP20 ILLUSTRATED PARTS BREAKDOWN Models CBN20 CBP20 SBN20 and SBP20 2 3 5 6 8 9 9 10...

Страница 21: ...94 08 Deflector Assembly 1 9 098271 09 098271 09 Ignitor Cable 1 10 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 Thermocouple Kit 1 12 103446 01...

Страница 22: ...more information visit www desatech com 22 ILLUSTRATED PARTS BREAKDOWN MODELS CBN20T CBP20T CBN30T CBP30T CBN20TK CBP20TK ILLUSTRATED PARTS BREAKDOWN Models CBN20T CBP20T CBN30T CBP30T CBN20TK and CB...

Страница 23: ...98271 09 098271 09 098271 09 098271 09 Ignitor Cable 1 10 098249 01 098249 01 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 11...

Страница 24: ...EAKDOWN MODELS CBT20NT CBT20PT CBT30NT CBT30PT ILLUSTRATED PARTS BREAKDOWN Models CBT20NT CBT20PT CBT30NT and CBT30PT 20 2 12 13 7 15 3 5 6 8 9 4 1 17 19 14 18 16 9 10 11 Alkaline Battery AA Battery P...

Страница 25: ...11 098271 11 098271 11 098271 11 Ignitor Cable 1 10 098249 01 098249 01 098249 01 098249 01 ODS Pilot Nut 2 11 110803 01 110803 02 110803 01 110803 02 ODS Pilot Assembly 1 110186 01 110186 01 110186 0...

Страница 26: ...nal factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does n...

Отзывы: