Fireplace inSTallaTion

SELECTING LOCATION

To determine safest and most efficient location 
for fireplace, you must take into consideration 
the following guidelines:
1.  Location must allow for proper clearances 

(see Figures 1 and 2).

2.  Consider  a  location  where  fireplace  will 

not be affected by drafts, air conditioning 
ducts, windows or doors.

3.  A location that avoids cutting of joists or 

roof rafters will make installation easier.

4.  An  outside  air  kit  is  available  with  this 

fireplace (see 

Optional Outside Air Kit

 on 

page 7).

MINIMUM CLEARANCE TO 
COMBUSTIBLES

Back and sides of fireplace   3/4" minimum*
Floor** 

0" minimum

Perpendicular wall to opening  14" minimum
Top spacers 

0" minimum

Mantel clearances 

see 

Mantels

, page 6 

Chimney outer pipe surface 

1" minimum

* Not required at nailing flanges
** See step 2 of 

Framing

 WARNING: Do not pack re

-

quired air spaces with insulation 

or other materials.

Minimum/Maximum Chimney Height

Minimum height of chimney, measured from 
base of fireplace to flue gas outlet of termina

-

tion, is 11.5 feet for straight flue or a flue with 
one elbow set. Maximum distance between 
elbows is 2 feet. For systems with two elbow 
sets,  minimum  height  is  22  feet.  Maximum 
height of any system is 50 feet. This measure

-

ment includes fireplace, chimney sections and 
height of termination assembly at level of flue 
gas outlet (see Figure 18, page 11).

FRAMING

1.  Frame opening for fireplace using dimen

-

sions shown in Figures 1 and 2.

2.  If  fireplace  is  to  be  installed  directly  on 

carpeting, tile (other than ceramic) or any 
combustible  material  other  than  wood 
flooring, fireplace must be installed upon 
a metal or wood panel extending full width 
and depth of fireplace.

3.  Set fireplace directly in front of this open

-

ing and slide unit back until nailing flanges 
touch side framing.

4.  Check  level  of  fireplace  and  shim  with 

sheet metal if necessary.

5.  Before  securing  fireplace  to  prepared 

framing, ember protector must be placed 
between hearth extension (not included) 
and under bottom front edge of fireplace 
to protect against glowing embers falling 
through. If fireplace is to be installed on 
a raised platform, a Z-type ember protec

-

tor  (not  included)  must  be  fabricated  to 
fit your required platform height. Ember 
protector should extend under fireplace a 
minimum of 1 

1

/

2

". Ember protector should 

be made of galvanized sheet metal (28 
gauge minimum) to prevent corrosion.

6.  Using screws or nails, secure fireplace to 

framing through flanges located on sides 
of fireplace.

22"

37.625"

44.25"

Figure 1 - Framing Dimensions

52 

1

/

2

"

15 

7

/

8

"

22 

1

/

2

"

72 

7

/

8

"

Maintain 3/4"

Clearance at

Sides and

Back of

Fireplace

3/4" Clearance Not 

Required at Nailing Flanges  

Figure 2 - Corner Installation

Содержание B42LI-M

Страница 1: ...r use with a vent free gas log heater approved to ANS Z21 11 2 standard A DESA Heating LLC hood must be installed when using a vent free log heater see Accessories page 18 This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacte...

Страница 2: ...amageor loss of life Refer to this manual for assistance or additional in formation Consult a qualified installer or local distributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This DESA Heating LLC fireplace and its components are safe when installed ac cording to this installation manual...

Страница 3: ...PACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS LEFT SIDE RIGHT SIDE NOT LESS THAN 14 TO PERPENDICULAR SIDEWALL SQUARE CHASE TOP TERMINATION 8 25 10 375 13 37 5 33 44 42 21 5 32 6 5 38 85 14 438 1 375 25 375 7 7 1 8 25 14 44 1 1 75 0 625 28 5 21 125 ...

Страница 4: ...ure ment includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 18 page 11 Framing 1 Frame opening for fireplace using dimen sions shown in Figures 1 and 2 2 If fireplace is to be installed directly on carpeting tile other than ceramic or any combustible material other than wood flooring fireplace must be installed upon a metal or wood panel e...

Страница 5: ...obtained from manufacturer or supplier of noncombustible material If hearth extension is to be covered use noncombustible mate rial such as tile slate brick concrete metal glass marble stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material see Figure 3 WARNING Hearthextension is to be installed on...

Страница 6: ...ptional with this fireplace for circulating models only Use of blowers or fans other than those manufactured by DESA Heating LLC voids warranty Fan is operated by pressing rocker switch see Figure 6 in lower right hand corner of fireplace face Blower is operated by turning control knob not shown Fan blower kit electrical connections are made through electrical cover plate on side of fireplace a sh...

Страница 7: ...Installation Air Inlet Eyebrow Vented Crawl Space Check Local Codes Before Installing in a Vented Crawl Space Venting Installation Optional Outside air Kit Model AK4 AK4F Installation of outside air kit should be per formed during rough framing of fireplace due to the nature of it s location Outside combus tion air is accessed through a vented crawl space AK4F or through a sidewall AK4 See Figure ...

Страница 8: ...e obstructed Never use blown insulation to fill chimney enclosure Continue to assemble chimney sections as outlined making sure that both inner and outer pipe sections are locked together When installing double wall snap lock chimney to gether it is important to assure joint between chimney sections is locked Check by pulling chimney upward after locking Chimney will not come apart if properly loc...

Страница 9: ...60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2 1 64 3 4 120 3 4 2 1 68 1 4 127 1 2 70 130 2 1 1 74 1 4 137 1 2 1 2 1 76 3 4 141 1 2 1 2 1 79 3 4 146 3 4 4 OFFSET CHART 22 50 FT SYSTEM HEIGHT 2 Min Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop S...

Страница 10: ...round perimeter of flashing to provide a proper seal Firestop Spacers FS 8DM Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance between chimney and combustible materials When pipe passes through a framed opening into a living space above firestop must be placed onto ceiling from below as shown in Figure 1...

Страница 11: ...rmination being used Flashing Cone Venting Installation Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 17 Termination Overlap Shingles Top and Sides Terminations with 16 slip pipe sections are available RTT 8DM and RTTL 8DM are approved for flashing installations When needed these a...

Страница 12: ... contact with sides and top around fireplace face It is important that combustible materials do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive 30E 8DM EFFECTIVE HEIGHT OF TERMINAT...

Страница 13: ...nd refractory knockout hole with refractory cement or commercial furnace cement Install gas appliance or cap off gas line if desired CAUTION Allgaspipingand connections must be tested for leaks after installation is com pleted After ensuring that gas valveison applysoapandwater solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR...

Страница 14: ...ass Doors Glass doors are optional with this fireplace When fireplace is in operation doors must be fully opened or fully closed position only or a fire hazard may be created see Figure 23 A fireplace equipped with glass doors oper ates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Exces sive heat within fireplace can r...

Страница 15: ...grate with DESA Heating LLC model 109910 01 only This gratehasbeendesignedtokeep the operation of your fireplace safe and efficient For further operating guidelines instruc tions and warranty information please re fer to your homeowner s guide or contact your authorized dealer Damper Handle 1 2 3 1 2 3 Damper Weight To Close Damper To Open Damper Figure 25 Damper Rod Technical Service You may have...

Страница 16: ...www desatech com 115386 01B 16 Parts Wood burning Fireplace MODEL B42LI M 11 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

Страница 17: ...8 Left Side Brick Liner 1 12 see page 18 Rear Brick Liner 1 13 see page 18 Right Side Brick Liner 1 14 see page 18 Bottom Brick Liner 1 15 see page 18 Front Bottom Brick Liner 1 16 21198 Blower Access Plate 1 17 20027 Refractory Retainer 2 18 109870 01 Circulation Plate 1 19 21366 Insulation Retainer 1 20 20280 Top Standoff 4 21 20023 Chimney Starter Collar 1 22 20088 Door Stop 1 23 11418 Push On ...

Страница 18: ...turn 30E 8DM Adjustable Hood Antique Brass Finish GA6053 Polished Brass Finish GA6052 Black Painted Finish GA6050 Required when installing a vent free gas log in this fireplace Storm Collar SC1 1 For RT 8DM and RTL 8DM SC1 2 For RTT 8DM and RTTL 8DM Bi Fold Glass Door BDB42 Black BDB42B Brushed Brass BDB42P Platinum Replacement Parts Standard brick liner Left 106971 01 Right 106970 01 Rear 108310 ...

Страница 19: ...inations RT 8DM RTL 8DM Round Top Terminations with Slip Section RTT 8DM RTTL 8DM Outside Air Kit for Side Wall Installation AK4 Outside Air Kit for Floor Installation AK4F Square Chase Top Termination ET 8DM ETO 8DM Econo Top Termination with Slip Section ETL 8DM ETLO 8DM Accessories Continued ...

Страница 20: ...DESA Heating LLC 2701 Industrial Drive Bowling Green KY 42101 www desatech com 1 866 672 6040 115386 01 Rev B 12 08 NOT A UPC 115386 01 ...

Отзывы: