Comfort Flame CDCFNRB Скачать руководство пользователя страница 6

www.fmiproducts.com

124979-01C

6

strip  and  caulk  around  windows  and  doors 
to keep the cold air out and the warm air in. 
During  heating  months,  home  owners  want 

their homes as airtight as possible.
While it is good to make your home energy 

efficient, your home needs to breathe. Fresh 

air must enter your home. All fuel-burning ap-
pliances need fresh air for proper combustion 
and ventilation.

Exhaust  fans,  fireplaces,  clothes  dryers  and 
fuel burning appliances draw air from the house 
to operate. You must provide adequate fresh 
air for these appliances. This will insure proper 

venting of vented fuel-burning appliances.

PROvIDING ADEqUATE vENTILATION

The following are excerpts from 

National Fuel 

Gas  Code,  ANSI  Z223.1/NFPA  54,  Air  for 
Combustion and Ventilation.

Figure 4 - Assembling Hood

Hood

Sheet Metal 

Screws

Firebox Top

Louver

aiR FoR ComBUsTioN aND VENTilaTioN

 WARNING: This heater shall 

not be installed in a room or space 

unless  the  required  volume  of 

indoor combustion air is provided 

by the method described in the 

National  Fuel  Gas  Code,  ANSI 

Z223.1/NFPA 54,

 the 

International 

Fuel  Gas  Code,

  or  applicable 

local codes. Read the following 

instructions to insure proper fresh 

air for this and other fuel-burning 

appliances in your home.

Today’s homes are built more energy efficient 
than ever. New materials, increased insulation 
and new construction methods help reduce 
heat  loss  in  homes. Home  owners  weather 

  WARNING:  Always  have 

screen in place before operating 

fireplace. This prevents exces

-

sive temperatures on fireplace 

surfaces.

 WARNING: Failure to position 

the parts in accordance with these 

diagrams  or  failure  to  use  only 

parts specifically approved with 

this fireplace may result in prop

-

erty damage or personal injury.

Tools Required:

•  Phillips screwdriver  •  slotted screwdriver
•  5/16" hex wrench 

•  scissors

1.  If  equipped,  lift  fireplace  screen  up  and 

pull  out  to  remove  (see  Figure  3).  Set 
screen  aside  until  installation  has  been 
completed.

2.  Cut two plastic straps to remove log from 

firebox cavity. Set log aside.

3.  An optional blower is available. See 

Ac-

cessories, 

page 31. Install optional blower 

now. Follow installation instructions pro

-

vided with blower.

4.  Locate  four  black  Phillips  sheet  metal 

screws in hardware packet.

5.  Slide hood between louver and firebox top 

and align screw holes.

Figure 3 - Removing and Installing Screen 

Screen

Shoulder Screw 

 

HooD assEmBly

6.  Insert  screws  as  shown  in  Figure  4. 

Tighten screws firmly.

Содержание CDCFNRB

Страница 1: ...e gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not...

Страница 2: ...the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product contains and or generat...

Страница 3: ...appliance should be located out oftrafficandawayfromfurniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Fireplace f...

Страница 4: ...air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if not enough fresh air is available See Air for Combustion...

Страница 5: ...ure for vent free room fireplaces The ODS pilot shuts off the fireplace if there is not enough fresh air Piezo Ignition System This fireplace has a piezo ignitor This sys tem requires no matches batte...

Страница 6: ...cal codes Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased...

Страница 7: ...Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicat...

Страница 8: ...fined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces...

Страница 9: ...below external regulator supplied by installer for propane LP units only piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union s...

Страница 10: ...ireplace cabinet to any combustible material and wall should follow diagram in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall Thi...

Страница 11: ...x combustible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the sides and top edge of the firebox Combustible materi als should never overlap the fi...

Страница 12: ...nationalproductstandard Follow all minimum clearances shown in this manual INSTALLATION Continued Figure 11 Minimum Mantel Clearances for Built In Installation Mantel Shelf Side of Firebox NOTICE Ifyo...

Страница 13: ...Gas line pressure must be no greater than 14 of water If gas line pressure is higher heater regulator damage could occur CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply This...

Страница 14: ...cluded from fireplace control to equipment shutoff valve through side access holes in outer casing 3 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line equ...

Страница 15: ...e supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all join...

Страница 16: ...d 54 above the floor in a location where there is good air circulation Avoid heat sources such as lamps direct sunlight fireplace or heat and air conditioning ducts 4 Gently remove cover of thermostat...

Страница 17: ...ORTANT The wire may be shortened but must not be lengthened 4 Connect one bare wire end to each of the terminals of the provided wall switch 5 Install the wall switch and cover in the wall INSTALLING...

Страница 18: ...pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob FOR YOUR SAFETY READ...

Страница 19: ...ing battery 3 Close equipment shutoff valve see Figure 17 page 15 WARNING Make sure re mote sensor selector switch is in the OFF position when you are away from home for long periods of time MANUAL LI...

Страница 20: ...ge Note When using the fireplace the first time the flame will be orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 32 turn fireplace off se...

Страница 21: ...ow been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air CLEANING AND...

Страница 22: ...le in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ign...

Страница 23: ...er ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local nat...

Страница 24: ...gulator 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observeminimuminstallation...

Страница 25: ...k See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defectiv...

Страница 26: ...www fmiproducts com 124979 01C 26 8 8 14 14 14 14 14 14 14 1 9 10 10 16 17 10 6 3 11 12 13 11 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 19 Parts Firebox Models CDCFPRB CDCFNRB CDCFPRB 1 CDCFNRB 1...

Страница 27: ...32 x 0 38 4 12 104313 01 Right Pin Hinge 1 13 104313 02 Left Pin Hinge 1 14 099230 02 Screw HWH SHLDR AB 10 x 0 63 14 15 111038 02 Remote Blower Bracket 1 16 M11084 26 Screw HWH AB 10 16 x 0 38 35 17...

Страница 28: ...www fmiproducts com 124979 01C 28 Parts REMOTE READY MODELS CDCFNRB CDCFPRB CDCFNRB 1 CDCFPRB 1 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 Natural Gas Only 9 21 22...

Страница 29: ...10 16 x 0 38 10 10 Chamber Floor 1 11 110793 01 Piezo Bracket 1 12 102445 01 Piezo Ignitor with Palnut Fastener 1 13 101628 01 Flexible Connector 1 14 098271 10 Ignitor Cable 1 15 M12461 26 Screw MX S...

Страница 30: ...tore Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced u...

Страница 31: ...AP6094 Platinum For all models Optional three sided perim eter trim kit for custom and recessed instal lations when unit is on the floor Provides a finished appearance by covering rough edges of wall...

Страница 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: