FIREPLACE CLEARANCES

  WARNING:  Maintain  the 

minimum  clearances  shown 

in Figure 7. If you can, provide 

greater  clearances  from  floor, 

ceiling and joining wall.

If your fireplace is to be used with an optional 
mantel, the installation instructions included 
with your mantel shows an approved method 
of attaching the fireplace/mantel system to a 
wall. 

IMPORTANT:

 Only use optional cabinet 

or  corner  mantels  specified  in  this  manual. 

Purchase the optional mantel from your dealer 
(see 

Accessories,

 page 31).

If your fireplace is to be recessed into the wall, 

see 

Built-In Fireplace Installation 

on page 10 

to secure your fireplace into the wall.

 CAUTION: If you install the 

fireplace in a home garage

•  fireplace pilot and burner must 

be at least 18" above floor.

•  locate fireplace where moving 

vehicle will not hit it.

For  convenience  and  efficiency,  install  fire

-

place

•  where there is easy access for operation, 

inspection and service

•  in coldest part of room
An optional blower kit is available from your 

dealer. See 

Accessories, 

page 31. If planning 

to use blower, follow instructions provided with 
blower for power source.

Minimum Clearances For Side 
Combustible Material, Side Wall and 

Ceiling

A.  Clearances from the side of the fireplace 

cabinet to any combustible material and 

wall should follow diagram in Figure 6.

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 
protrudes 3 

1

/

2

" from the wall. This com

-

bustible material must be 4" from the side 
of the fireplace opening (see Figure 7).

iNsTallaTioN

Continued

Figure 7 - Minimum Clearance for 

Combustible to Wall 

*Minimum 16" from Side Wall 

*

Example

B.  Clearances from the top of the fireplace 

opening to the ceiling should not be less 

than 36".

C.  For mantel clearances, see Figure 11 on 

page 12.

MINIMUM CLEARANCE TO 

COMBUSTIBLE MATERIALS

Top 36", Left and Right Sides 6",

 

Bottom and Rear 0", Front 36"

bUILT-IN FIREPLACE INSTALLATION

Built-in  installation  of  this  fireplace  involves 
installing fireplace into a framed-in enclosure. 
This  makes  the  front  of  fireplace  flush  with 
wall. Trim  will  extend  past  sides  of  fireplace 
approximately 1/2". This will cover the rough 
edges of the wall opening. If installing a built-
in mantel above the fireplace, you must follow 
the clearances shown in Figure 11, page 12. 
Follow  the  instructions  below  to  install  the 
fireplace in this manner.

Actual

Framing

Height

26"

26 

7

/

8

"

Front Width

26 

3

/

4

"

26 

7

/

8

"

Depth

14 

1

/

4

"

15 

1

/

4

"

1.  Frame in rough opening. Use dimensions 

shown in Figure 8, page 11, for the rough 
opening.  If  installing  in  a  corner,  use 
dimensions shown in Figure 9, page 11, 

for the rough opening. The height is 26 

7

/

8

which  is  the  same  as  the  wall  opening 

above.

Содержание CDCFNRB

Страница 1: ...e gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not...

Страница 2: ...the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product contains and or generat...

Страница 3: ...appliance should be located out oftrafficandawayfromfurniture and draperies Do not place clothing or other flammable material on or near the appliance Never place any objects on the heater Fireplace f...

Страница 4: ...air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if not enough fresh air is available See Air for Combustion...

Страница 5: ...ure for vent free room fireplaces The ODS pilot shuts off the fireplace if there is not enough fresh air Piezo Ignition System This fireplace has a piezo ignitor This sys tem requires no matches batte...

Страница 6: ...cal codes Read the following instructionstoinsureproperfresh air for this and other fuel burning appliances in your home Today s homes are built more energy efficient than ever New materials increased...

Страница 7: ...Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicat...

Страница 8: ...fined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces...

Страница 9: ...below external regulator supplied by installer for propane LP units only piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection ground joint union s...

Страница 10: ...ireplace cabinet to any combustible material and wall should follow diagram in Figure 6 Example The face of a mantel bookshelf etc is made of combustible material and protrudes 3 1 2 from the wall Thi...

Страница 11: ...x combustible materials such as wall board gypsum board sheet rock drywall plywood etc may be butted up next to the sides and top edge of the firebox Combustible materi als should never overlap the fi...

Страница 12: ...nationalproductstandard Follow all minimum clearances shown in this manual INSTALLATION Continued Figure 11 Minimum Mantel Clearances for Built In Installation Mantel Shelf Side of Firebox NOTICE Ifyo...

Страница 13: ...Gas line pressure must be no greater than 14 of water If gas line pressure is higher heater regulator damage could occur CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply This...

Страница 14: ...cluded from fireplace control to equipment shutoff valve through side access holes in outer casing 3 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line equ...

Страница 15: ...e supply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all join...

Страница 16: ...d 54 above the floor in a location where there is good air circulation Avoid heat sources such as lamps direct sunlight fireplace or heat and air conditioning ducts 4 Gently remove cover of thermostat...

Страница 17: ...ORTANT The wire may be shortened but must not be lengthened 4 Connect one bare wire end to each of the terminals of the provided wall switch 5 Install the wall switch and cover in the wall INSTALLING...

Страница 18: ...pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 30 sec onds after lighting pilot After 30 seconds release control knob FOR YOUR SAFETY READ...

Страница 19: ...ing battery 3 Close equipment shutoff valve see Figure 17 page 15 WARNING Make sure re mote sensor selector switch is in the OFF position when you are away from home for long periods of time MANUAL LI...

Страница 20: ...ge Note When using the fireplace the first time the flame will be orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 32 turn fireplace off se...

Страница 21: ...ow been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air CLEANING AND...

Страница 22: ...le in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ign...

Страница 23: ...er ODS pilot lights keep control knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local nat...

Страница 24: ...gulator 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural gas company 3 Observeminimuminstallation...

Страница 25: ...k See Warning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defectiv...

Страница 26: ...www fmiproducts com 124979 01C 26 8 8 14 14 14 14 14 14 14 1 9 10 10 16 17 10 6 3 11 12 13 11 15 16 18 16 16 16 16 16 16 2 5 16 16 16 16 7 4 19 Parts Firebox Models CDCFPRB CDCFNRB CDCFPRB 1 CDCFNRB 1...

Страница 27: ...32 x 0 38 4 12 104313 01 Right Pin Hinge 1 13 104313 02 Left Pin Hinge 1 14 099230 02 Screw HWH SHLDR AB 10 x 0 63 14 15 111038 02 Remote Blower Bracket 1 16 M11084 26 Screw HWH AB 10 16 x 0 38 35 17...

Страница 28: ...www fmiproducts com 124979 01C 28 Parts REMOTE READY MODELS CDCFNRB CDCFPRB CDCFNRB 1 CDCFPRB 1 16 15 15 16 12 12 11 9 9 9 10 5 17 18 13 19 2 1 4 3 14 7 6 8 20 Natural Gas Only 9 21 22...

Страница 29: ...10 16 x 0 38 10 10 Chamber Floor 1 11 110793 01 Piezo Bracket 1 12 102445 01 Piezo Ignitor with Palnut Fastener 1 13 101628 01 Flexible Connector 1 14 098271 10 Ignitor Cable 1 15 M12461 26 Screw MX S...

Страница 30: ...tore Call FMI PRODUCTS LLC at 1 866 328 4537 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced u...

Страница 31: ...AP6094 Platinum For all models Optional three sided perim eter trim kit for custom and recessed instal lations when unit is on the floor Provides a finished appearance by covering rough edges of wall...

Страница 32: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...

Отзывы: